CoChat

Improvement in the Prediction of Ventilator Weaning Outcomes by an Artificial Neural Network in a Medical ICU

Open access
Kuo, Hung-Ju, Chiu, Hung-Wen, Lee, Chun-Nin, Chen, Tzu-Tao, Chang, Chih-Cheng, Bien, Mauo-Ying · 2015 · Respiratory Care
Cited by 72

The DOI matches its Crossref record.

Abstract

BACKGROUND: Twenty-five to 40% of patients pass a spontaneous breathing trial (SBT) but fail to wean from mechanical ventilation. There is no single appropriate and convenient predictor or method that can help clinicians to accurately predict weaning outcomes. This study designed an artificial neural network (ANN) model for predicting successful extubation in mechanically ventilated patients. METHODS: Ready-to-wean subjects (N = 121) hospitalized in medical ICUs were recruited and randomly divided into training (n = 76) and test (n = 45) sets. Eight variables consisting of age, reasons for intubation, duration of mechanical ventilation, Acute Physiology and Chronic Health Evaluation II score, mean inspiratory and expiratory times, mean breathing frequency, and mean expiratory tidal volume in a 30-min SBT (pressure support ventilation of 5 cm H2O and PEEP of 5 cm H2O) were selected as the ANN input variables. The prediction performance of the ANN model was compared with the rapid shallow breathing index (RSBI), maximum inspiratory pressure, RSBI at 1 min (RSBI1) and 30 min (RSBI30) in an SBT, and absolute percentage change in RSBI from 1 to 30 min in an SBT (ΔRSBI30) using a confusion matrix and receiver operating characteristic curves. RESULTS: The area under the receiver operating characteristic curves in the test set of the ANN model was 0.83 (95% CI 0.69-0.92, P < .001), which is better than any one of the following predictors: 0.66 (95% CI 0.50-0.80, P = .04) for RSBI, 0.52 (95% CI 0.37-0.67, P = .86) for maximum inspiratory pressure, 0.53 (95% CI 0.37-0.68, P = .79) for RSBI1, 0.60 (95% CI 0.44-0.74, P = .34) for RSBI30, and 0.51 (95% CI 0.36-0.66, P = .91) for ΔRSBI30. Predicting successful extubation based on the ANN model of the test set had a sensitivity of 82%, a specificity of 73%, and an accuracy rate of 80%, with an optimal threshold of ≥ 0.5 selected from the training set. CONCLUSIONS: The ANN model improved the accuracy of predicting successful extubation. By applying it clinically, clinicians can select the earliest appropriate weaning time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.03648

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Kuo, H.-J., Chiu, H.-W., Lee, C.-N., Chen, T.-T., Chang, C.-C., & Bien, M.-Y.
Venue
Respiratory Care
Published
2015-11
Volume
60
Issue
11
Pages
1560-1569
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2178549406
Cited by
72
References
0
FWCI
2.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement in the Prediction of Ventilator Weaning Outcomes by an Artificial Neural Network in a Medical ICU. https://app.cochat.ai/papers/10.4187/respcare.03648
The paper
Kuo, H.-J., Chiu, H.-W., Lee, C.-N., Chen, T.-T., Chang, C.-C., & Bien, M.-Y. (2015). Improvement in the Prediction of Ventilator Weaning Outcomes by an Artificial Neural Network in a Medical ICU. Respiratory Care. https://doi.org/10.4187/respcare.03648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.