Comparison of a New Forehead Reflectance Pulse Oximeter Sensor With a Conventional Digit Sensor in Pediatric Patients

Berkenbosch, John W, Tobias, Joseph D·2006·Respiratory Care

Abstract

Background During conditions of poor perfusion, the accuracy of conventional extremity-based pulse oximeters may be limited. Limited evidence suggests that forehead perfusion may be better preserved during such periods, but pediatric experience with newer forehead reflectance sensors is limited. We prospectively compared the accuracy of a forehead reflectance sensor, the Max-Fast, with a new-generation digit sensor in pediatric patients. Methods Pediatric patients > 10 kg and who had arterial catheters were eligible for enrollment. Blood oxygen saturation was simultaneously measured with forehead and digit sensors, and compared to corresponding CO-oximetry-measured arterial oxygen saturation values (S(aO2)) taken at the same times. We used Bland-Altman analysis to calculate the bias and precision of the forehead sensor and the digit sensor relative to the S(aO2) values. Results We obtained 116 sample sets from 28 patients. The S(aO2) values ranged from 84.1% to 99.2%. The bias and precision of the forehead-to-S(aO2) difference were 0.6% and 2.7%, respectively, versus 1.4% and 2.6%, respectively, for the digit-to-S(aO2) difference (p Conclusions The Max-Fast sensor estimated S(aO2) as accurately as did a new-generation digit sensor in well-perfused pediatric patients.

Integrity signals

Registry

Crossref · 10.4187/respcare.06510726

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For infants who experience hypothermia or low body temperatures, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs.

    “In addition, for infants who experience hypothermia or low body temperatures, which is common for infants in the Ethiopian NICU, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs8–11.”

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 24 · Cited by 38

Authors
Berkenbosch, J. W., & Tobias, J. D.
Affiliations
  • University of Louisville (US)
  • University of Missouri (US)
Corresponding author
Berkenbosch, John W
Venue
Respiratory Care
Published
2006-07
Volume
51
Issue
7
Pages
726-731
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2117847536
Cited by
38
References
24
Citations by year
2025: 3 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 5 · 2019: 1 · 2018: 2 · 2017: 2 · 2015: 1 · 2014: 2 · 2013: 2
FWCI
2.05
Type
journal article
Language
en
Open access
closed
Locations
  • Respiratory Care (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry accuracy, arterial oxygen saturation, pediatric patients, vasoactive drugs, arterial catheters
MeSH terms
Adolescent, Blood Gas Monitoring, Transcutaneous, Child, Child, Preschool, Electrodes, Extremities, Female, Forehead, Humans, Male, Prospective Studies, Regression Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review