A guide to practical aspects of measurement of human nasal airflow by rhinomanometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The guide is intended for all those interested in measuring human nasal airflow by rhinomanometry, either for clinical or research purposes. The guide is written in non-technical language so that it may be understood by nursing and support staff who may need to make measurements using rhinomanometry. It is not a systematic review of the literature but a personal view based on over 40 years experience of measuring nasal airflow. The guide introduces the basic principles of nasal airflow and pressure and their measurement. The following topics are discussed: anterior and posterior rhinomanometry and their relative problems and benefits, control of errors in measurement, standard operating procedures, calibration of equipment, measurement of the totally obstructed nose, reproducibility and sensitivity of rhinomanometry, hygiene, factors influencing nasal airflow such as rest and exercise, alcohol, medicines, temperature and humidity and diseases such as common cold and allergy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rhinomanometry and Diagnosis of Nasal Obstruction
McCaffrey, T. (1990) · Facial Plastic Surgery · doi:10.1055/s-2008-1064694 · Cited by 21
Cited by
Position Paper on Nasal Obstruction: Evaluation and Treatment
SEAIC Rhinoconjunctivitis Committee & SEORL Rhinology, A., Valero, A., Navarro, A., del Cuvillo, A., Alobid, I., Benito, Jr., Colás, C., de los Santos, G., Fernández Liesa, R., García-Lliberós, A., et al. (2018) · Journal of Investigational Allergology and Clinical Immunology · doi:10.18176/jiaci.0232 · Cited by 76
Validation of the sino-nasal outcome test-23 in septorhinoplasty surgery
Takhar, A., Stephens, J., Randhawa, P. S., Poirrier, A. L., & Andrews, P. (2014) · Rhinology journal · doi:10.4193/rhin14.009 · Cited by 26
“Objective measures of nasal patency (nasal peak flow, rhinomanometry, acoustic rhinometry) have limitations in the clinical setting (21,22) and although they provide an objective measure they reflect only one aspect of the disease.”
BackgroundCorrelation between peak nasal inspiratory flow and peak expiratory flow in children and adolescents
Chaves, C., Ibiapina, C., Andrade, C. R., Godinho, R., Alvim, C. G., & Cruz, A. A. (2012) · Rhinology journal · doi:10.4193/rhin12.073 · Cited by 20
Eccles, R., & Voelker, M. (2014) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.39 · Cited by 12
Self-citation
Metadata
- Authors
- Eccles, R.
- Venue
- Rhinology journal
- Publisher
- Stichting Nase
- Published
- 2011-03-01
- Volume
- 49
- Issue
- 1
- Pages
- 2-10
- ISSN
- 0300-0729 (ISSN-L)
- OpenAlex
- W1820892109
- Cited by
- 45
- References
- 1
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.