CoChat

Comparison between unilateral PNIF and rhinomanometry in healthy and obstructed noses

Ottaviano, G., Lund, V., Nardello, E., Scarpa, B., Frasson, G., Staffieri, A., Scadding, G. · 2014 · Rhinology journal
Cited by 40

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Aims: Peak Nasal Inspiratory Flow (PNIF) is an easy method to assess nasal patency. Normative unilateral PNIF data in adults have been proposed. The study purpose was to compare PNIF and unilateral PNIF values to total and unilateral nasal resistances measured by anterior active rhinomanometry (AAR) in subjects with and without nasal obstruction to see whether unilateral PNIFis sensitive to detect nasal obstruction. Methods and results: Measurements of PNIF, unilateral PNIF and AAR were performed in 125 volunteers. Seventy of them were healthy subjects not complaining of nasal symptoms and entered into the study as the'normal' group. The other group consisted of fifty-five symptomatic subjects.Data were analysed to show the correlation between PNIF, unilateral PNIF and nasal resistances. The ability of PNIF and AAR in predicting pathologies were compared by receiver operating characteristic (ROC) analysis indicating that PNIF and AAR have a similar and significant power to discriminate pathologic from healthy subjects. Conclusion: The measurement of unilateral PNIF could be a helpful method to support the diagnosis of nasal blockage also in those cases with single nostril obstruction, but, in cases of doubt, AAR should also be performed to improve diagnostic accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4193/rhino13.037

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 4

  1. Clarke RW, Jones AS, Richardson H. Peak nasal flow-the plateau effect. J Laryngol Otol. 1995; 109: 399-402.
  2. Lund VJ. Diagnosis is not the end. Rhinology 2012; 50: 337-338.
  3. Gleeson MJ, Youlten LJF, Shelton DM, Siodlak MZ, Eiser NM, Wengraf CL. Assessment of nasal airway patency: a comparation of four methods. Clin Otholaryngol. 1986; 11: 99-107.
  4. Bermüller C, Kirsche H, Rettinger G, Riechelmann H. Diagnostic accuracy of peak nasal inspiratory flow and rhinoma- nometr y in functional rhinosurger y. Laryngoscope. 2008; 118: 605-610.

Cited by

See all 40

Metadata

Authors
Ottaviano, G., Lund, V., Nardello, E., Scarpa, B., Frasson, G., Staffieri, A., & Scadding, G.
Venue
Rhinology journal
Published
2014-03-01
Volume
52
Issue
1
Pages
25-30
ISSN
0300-0729
Cited by
40
References
28

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison between unilateral PNIF and rhinomanometry in healthy and obstructed noses. https://app.cochat.ai/papers/10.4193/rhino13.037
The paper
Ottaviano, G., Lund, V., Nardello, E., Scarpa, B., Frasson, G., Staffieri, A., & Scadding, G. (2014). Comparison between unilateral PNIF and rhinomanometry in healthy and obstructed noses. Rhinology journal. https://doi.org/10.4193/rhino13.037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.