Lumped Parameter Outflow Models for 1-D Blood Flow Simulations: Effect on Pulse Waves and Parameter Estimation
The DOI matches its OpenAlex record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Several lumped parameter, or zero-dimensional (0-D), models of the microcirculation are coupled in the time domain to the nonlinear, one-dimensional (1-D) equations of blood flow in large arteries. A linear analysis of the coupled system, together with in vivo observations, shows that: (i) an inflow resistance that matches the characteristic impedance of the terminal arteries is required to avoid non-physiological wave reflections; (ii) periodic mean pressures and flow distributions in large arteries depend on arterial and peripheral resistances, but not on the compliances and inertias of the system, which only affect instantaneous pressure and flow waveforms; (iii) peripheral inertias have a minor effect on pulse waveforms under normal conditions; and (iv) the time constant of the diastolic pressure decay is the same in any 1-D model artery, if viscous dissipation can be neglected in these arteries, and it depends on all the peripheral compliances and resistances of the system. Following this analysis, we propose an algorithm to accurately estimate peripheral resistances and compliances from in vivo data. This algorithm is verified against numerical data simulated using a 1-D model network of the 55 largest human arteries, in which the parameters of the peripheral windkessel outflow models are known a priori. Pressure and flow waveforms in the aorta and the first generation of bifurcations are reproduced with relative root-mean-square errors smaller than 3%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Mechanics of the Circulation
Caro, C. G., Pedley, T. J., Schroter, R. C., Seed, W. A., & Parker, K. H. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139013406 · Cited by 912
Self-citationThe Fluid Mechanics of Large Blood Vessels
Pedley, T. J., & Fung, Y. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138235 · Cited by 910
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 2×
“4 MPa, based on the data published in [32] for the human aorta.”
BackgroundMethodMulti-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517 · cited 1×
“This idea has been previously implemented to simulate pulse wave propagation in systemic human arteries [6, 22, 32].”
MethodComputer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511 · cited 5×
“6 shows two aortic pressure and flow waveforms simulated using the 1-D model of the 55 larger systemic arteries in the human proposed in [28] (Fig.”
BackgroundMethodInfluentialOne-dimensional models for blood flow in arteries
Formaggia, L., Lamponi, D., & Quarteroni, A. M. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007980.01347.29 · Cited by 500 · cited 1×
“Several comparisons against in vivo [19, 26] and in vitro [2, 16] data have shown the ability of the nonlinear, 1-D equations of blood flow in compliant vessels [11, 14, 21, 23, 29] to capture the main features of pressure and flow waveforms in large arteries.”
BackgroundOne-dimensional modelling of a vascular network in space-time variables
Sherwin, S. J., Franke, V., Peiró, J., & Parker, K. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007979.32871.e2 · Cited by 464 · cited 3×
“2) in arterial networks using a discontinuous Galerkin scheme with a Legendre polynomial spectral/hp-spatial discretization and a second-order Adams-Bashforth time-integration scheme [2, 23], and we have validated this formulation against in vitro data [2, 16].”
BackgroundMethodSelf-citationDie grundform des arteriellen pulses
Frank, O. (1899) · Medical Entomology and Zoology · Cited by 457
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Self-citationStructured tree outflow condition for blood flow in larger systemic arteries
Olufsen, M. S. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.1.h257 · Cited by 439 · cited 1×
“Alternatively, the remainder of the arterial system can be simulated using structured tree models based on Womersley’s elastic vessel theory under the assumption of periodic flow [18,19].”
Method
Cited by
Quarteroni, A., Lassila, T., Rossi, S., & Ruiz-Baier, R. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.05.031 · Cited by 248
“There has been much interest in recent years in constructing extremely detailed models of the human arterial tree (see [3, 29, 30, 108] and the references therein) including aspects such as physiological vessel tapering, viscoelasticity, baroreflex autoregulation, and many others.”
BackgroundMethods of Blood Flow Modelling
Bessonov, N., Sequeira, A., Simakov, S., Vassilevskii, Y., & Volpert, V. (2016) · Mathematical Modelling of Natural Phenomena · doi:10.1051/mmnp/201611101 · Cited by 205
“Many authors perform time-domain coupling of the 1D blood flow models with electric circuits (lumped parameters) 0D models [4, 16, 36, 73, 80, 87, 92].”
BackgroundOn the coupling of systems of hyperbolic conservation laws with ordinary differential equations
Borsche, R., Colombo, R. M., & Garavello, M. (2010) · Nonlinearity · doi:10.1088/0951-7715/23/11/002 · Cited by 55
Metadata
- Authors
- Alastruey, J., Parker, K. H., Peiró, J., & Sherwin, S. J.
- Venue
- Communications in Computational Physics
- Publisher
- Cambridge University Press
- Published
- 2008-01-01
- Volume
- 4
- Issue
- 2
- Pages
- 317-336
- ISSN
- 1815-2406 (ISSN-L)
- OpenAlex
- W2272147995
- Cited by
- 185
- References
- 25
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.