The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Assessment of the SYNTAX score in the Syntax study
Abstract
AIMS: The SYNTAX score has been designed to better anticipate the risks of percutaneous or surgical revascularisation, taking into account the functional impact of the coronary circulation with all its anatomic components including the presence of bifurcations, total occlusions, thrombus, calcification, and small vessels. The purpose of this paper is to describe the baseline assessment of the SYNTAX score in the Syntax randomised trial, the corelab reproducibility, the potential difference in score assessment between the investigator and the corelab, and to ascertain the impact on one-year outcome after either percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) in patients with complex coronary artery disease. METHODS AND RESULTS: To assess the reliability of Syntax scoring, 100 diagnostic angiograms from the Syntax trial were randomly selected and assessed independently by two observers. Intra-observer variability was assessed by analysing 91 sets of angiograms after an interval of at least eight weeks by one of the observers. Clinical outcomes in the randomised cohort of the Syntax trial up to one year are presented with stratification by tertile group of the SYNTAX score. The weighted kappa value for the inter-observer reproducibility on the global score was 0.45, while the intra-observer weighted kappa value was 0.59. The SYNTAX score as calculated by investigators consistently underscored the corelab score by 3.4 points. When the Syntax randomised cohort was stratified by tertiles of the SYNTAX score, there were similar or non-significantly different MACCE rates in those with low or intermediate scores; however in the top tertile the MACCE rate was greater in those receiving PCI compared to CABG. CONCLUSIONS: The SYNTAX score is a visual coronary score with an acceptable corelab reproducibility that has an impact on the one-year outcome of those having PCI, whereas it has no effect on the one-year outcome following surgical revascularisation. The SYNTAX score tool is likely to be useful in a wide range of patients with complex coronary disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Statistical Methods for Rates and Proportions.
Everitt, B. S., & Fleiss, J. L. (1981) · Biometrics · doi:10.2307/2530193 · Cited by 8,990
Serruys, P. W., Morice, M.-C., Kappetein, A. P., Colombo, A., Holmes, D. R., Mack, M. J., Ståhle, E., Feldman, T. E., van den Brand, M., Bass, E. J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0804626 · Cited by 4,331
Self-citationEuropean system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Toutenburg, H. (1974) · Biometrische Zeitschrift · doi:10.1002/bimj.19740160814 · Cited by 1,538
Eurp-pean system for cardiac operative risk evaluation (Euro SCORE)
Nashef, S. A. M. (1999) · Medical Entomology and Zoology · Cited by 1,349
Parsonnet, V., DEAN, D. L., & Bernstein, A. D. (1989) · PubMed · Cited by 1,103
Hlatky, M. A., Boothroyd, D. B., Bravata, D. M., Boersma, E., Booth, J., Brooks, M. M., Carrié, D., Clayton, T. C., Danchin, N., Flather, M., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60552-3 · Cited by 735
Self-citationA New Classification of Coronary Bifurcation Lesions
Medina, A., Suárez de Lezo, J., & Pan, M. (2006) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(06)60130-8 · Cited by 640
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Serruys, P. W., Ong, A. T. L., van Herwerden, L. A., Sousa, J. E., Jatene, A., Bonnier, J. J. R. M., Schönberger, J. P. M. A., Buller, N., Bonser, R., Disco, C., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.082 · Cited by 608
Self-citationACCF/SCAI/STS/AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization
Patel, M. R., Dehmer, G. J., Hirshfeld, J. W., Smith, P. K., & Spertus, J. A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.005 · Cited by 458
CORONARY REVASCULARIZATION WRITING GROUP, Patel, M. R., Dehmer, G. J., Hirshfeld, J. W., Smith, P. K., & Spertus, J. A. (2009) · Circulation · doi:10.1161/circulationaha.108.191768 · Cited by 448
Hoffman, S. N., TenBrook, J. A., Wolf, M. P., Wong, J. B., Pauker, S. G., & Salem, D. N. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00157-8 · Cited by 407
Ong, A. T. L., Serruys, P. W., Mohr, F. W., Morice, M.-C., Kappetein, A. P., Holmes, D. R., Mack, M. J., van den Brand, M., Morel, M.-A., van Es, G.-A., et al. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.07.017 · Cited by 338
Self-citationLeaman, D. M., Brower, R. W., Meester, G. T., Serruys, P., & van den Brand, M. (1981) · Circulation · doi:10.1161/01.cir.63.2.285 · Cited by 243
Self-citationEllis, S., Alderman, E. L., Cain, K. C., Wright, A., Bourassa, M. G., & Fisher, L. D. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90336-7 · Cited by 106
Hermans, W. R. M., Foley, D. P., Rensing, B. J. W. M., Rutsch, W. R., Heyndrickx, G. R., Danchin, N., Mast, G., Hanet, C., Lablanche, J., Rafflenbeul, W., et al. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90211-t · Cited by 103
Self-citation
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Farooq, V., van Klaveren, D., Steyerberg, E. W., Meliga, E., Vergouwe, Y., Chieffo, A., Kappetein, A. P., Colombo, A., Holmes, D. R., Mack, M., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60108-7 · Cited by 840
Self-citationMorice, M.-C., Serruys, P. W., Kappetein, A. P., Feldman, T. E., Ståhle, E., Colombo, A., Mack, M. J., Holmes, D. R., Torracca, L., van Es, G.-A., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.899211 · Cited by 642
Self-citationKappetein, A. P., Feldman, T. E., Mack, M. J., Morice, M.-C., Holmes, D. R., Ståhle, E., Dawkins, K. D., Mohr, F. W., Serruys, P. W., & Colombo, A. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr213 · Cited by 560
Self-citationSerruys, P. W., Onuma, Y., Dudek, D., Smits, P. C., Koolen, J., Chevalier, B., de Bruyne, B., Thuesen, L., McClean, D., van Geuns, R.-J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.050 · Cited by 525
Self-citation
Metadata
- Authors
- Serruys, P., Onuma, Y., Garg, S., Sarno, G., van den Brand, M., Kappetein, A.-P., Van Dyck, N., Mack, M., Holmes, D., Feldman, T., Morice, M.-C., Colombo, A., Bass, E., Leadley, K., Dawkins, K., van Es, G.-A., Morel, M.-A., & Mohr, F.
- Venue
- EuroIntervention
- Publisher
- Europa Digital & Publishing
- Published
- 2009-05
- Volume
- 5
- Issue
- 1
- Pages
- 50-56
- ISSN
- 1774-024X (ISSN-L)
- OpenAlex
- W1975818117
- Cited by
- 632
- References
- 20
- FWCI
- 36.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.