Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 546

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Left atrial appendage occlusion for stroke prevention in atrial fibrillation: multicentre experience with the AMPLATZER Cardiac Plug

Open access
Tzikas, Apostolos, Shakir, Samera, Gafoor, Sameer, Omran, Heyder, Berti, Sergio, Santoro, Gennaro, Kefer, Joelle, Landmesser, Ulf, Nielsen-Kudsk, Jens Erik, Cruz-Gonzalez, Ignacio, Sievert, Horst, Tichelbäcker, Tobias, Kanagaratnam, Prapa, Nietlispach, Fabian, Aminian, Adel, Kasch, Friederike, Freixa, Xavier, Danna, Paolo, Rezzaghi, Marco, Vermeersch, Paul, Stock, Friederike, Stolcova, Miroslava, Costa, Marco, Ibrahim, Reda, Schillinger, Wolfgang, Meier, Bernhard, Park, Jai-Wun·2016·EuroIntervention

Abstract

AIMS: To investigate the safety, feasibility, and efficacy of left atrial appendage occlusion (LAAO) with the AMPLATZER Cardiac Plug (ACP) for stroke prevention in patients with atrial fibrillation (AF). METHODS AND RESULTS: Data from consecutive patients treated in 22 centres were collected. A total of 1,047 patients were included in the study. Procedural success was 97.3%. There were 52 (4.97%) periprocedural major adverse events. Follow-up was complete in 1,001/1,019 (98.2%) of successfully implanted patients (average 13 months, total 1,349 patient-years). One-year all-cause mortality was 4.2%. No death at follow-up was reported as device-related. There were nine strokes (0.9%) and nine transient ischaemic attacks (0.9%) during follow-up. The annual rate of systemic thromboembolism was 2.3% (31/1,349 patient-years), which is a 59% risk reduction. There were 15 major bleedings (1.5%) during follow-up. The annual rate of major bleeding was 2.1% (28/1,349 patient-years), which is a 61% risk reduction. Patients with single LAAO on aspirin monotherapy or no therapy and longer follow-up had fewer cerebral and fewer bleeding events. CONCLUSIONS: In this multicentre study, LAAO with the ACP showed high procedural success and a favourable outcome for the prevention of AF-related thromboembolism. Modification in antithrombotic therapy after LAAO may result in reduction of bleeding events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4244/eijy15m01_06

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 546

Metadata

Authors
Tzikas, A., Shakir, S., Gafoor, S., Omran, H., Berti, S., Santoro, G., Kefer, J., Landmesser, U., Nielsen-Kudsk, J. E., Cruz-Gonzalez, I., Sievert, H., Tichelbäcker, T., Kanagaratnam, P., Nietlispach, F., Aminian, A., Kasch, F., Freixa, X., Danna, P., Rezzaghi, M., Vermeersch, P., Stock, F., Stolcova, M., Costa, M., Ibrahim, R., Schillinger, W., Meier, B., & Park, J.-W.
Venue
EuroIntervention
Published
2016-02
Volume
11
Issue
10
Pages
1170-1179
ISSN
1774-024X (ISSN-L)
OpenAlex
W132631509
Cited by
546
References
20
FWCI
63.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left atrial appendage occlusion for stroke prevention in atrial fibrillation: multicentre experience with the AMPLATZER Cardiac Plug. https://app.cochat.ai/papers/10.4244/eijy15m01_06
The paper
Tzikas, A., Shakir, S., Gafoor, S., Omran, H., Berti, S., Santoro, G., Kefer, J., Landmesser, U., Nielsen-Kudsk, J. E., Cruz-Gonzalez, I., Sievert, H., Tichelbäcker, T., Kanagaratnam, P., Nietlispach, F., Aminian, A., Kasch, F., Freixa, X., Danna, P., Rezzaghi, M., . . . Park, J.-W. (2016). Left atrial appendage occlusion for stroke prevention in atrial fibrillation: multicentre experience with the AMPLATZER Cardiac Plug. EuroIntervention. https://doi.org/10.4244/eijy15m01_06

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.