The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Use and Limitations of E/e' to Assess Left Ventricular Filling Pressure by Echocardiography
Open accessAbstract
Measurement of left ventricular (LV) filling pressure is useful in decision making and prediction of outcomes in various cardiovascular diseases. Invasive cardiac catheterization has been the gold standard in LV filling pressure measurement, but carries the risk of complications and has a similar predictive value for clinical outcomes compared with non-invasive LV filling pressure estimation by echocardiography. A variety of echocardiographic measurement methods have been suggested to estimate LV filling pressure. The most frequently used method for this purpose is the ratio between early mitral inflow velocity and mitral annular early diastolic velocity (E/e'), which has become central in the guidelines for diastolic evaluation. This review will discuss the use the E/e' ratio in prediction of LV filling pressure and its potential pitfalls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Alterations in the determinants of diastolic suction during pacing tachycardia
Bell, S. P., Nyland, L., Tischler, M. D., McNabb, M., Granzier, H., & LeWinter, M. M. (2000) · Circulation Research · doi:10.1161/01.res.87.3.235 · Cited by 190
Cited by
Marwick, T. H., Gillebert, T. C., Aurigemma, G., Chirinos, J., Derumeaux, G., Galderisi, M., Gottdiener, J., Haluska, B., Ofili, E., Segers, P., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.05.002 · Cited by 583
Self-citationSoft robotic sleeve supports heart function
Roche, E. T., Horvath, M. A., Wamala, I., Alazmani, A., Song, S.-E., Whyte, W., Machaidze, Z., Payne, C. J., Weaver, J. C., Fishbein, G., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf3925 · Cited by 425
Metadata
- Authors
- Park, J.-H., & Marwick, T. H.
- Venue
- Journal of Cardiovascular Ultrasound
- Publisher
- Korean Society of Echocardiography
- Published
- 2011
- Volume
- 19
- Issue
- 4
- Pages
- 169
- ISSN
- 1975-4612 (ISSN-L)
- 2005-9655
- OpenAlex
- W1991946883
- Cited by
- 219
- References
- 4
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use and Limitations of E/e' to Assess Left Ventricular Filling Pressure by Echocardiography. https://app.cochat.ai/papers/10.4250/jcu.2011.19.4.169
- The paper
- Park, J.-H., & Marwick, T. H. (2011). Use and Limitations of E/e' to Assess Left Ventricular Filling Pressure by Echocardiography. Journal of Cardiovascular Ultrasound. https://doi.org/10.4250/jcu.2011.19.4.169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.