The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Shear Properties of Brain Tissue over a Frequency Range Relevant for Automotive Impact Situations: New Experimental Results
Abstract
This research aims at improving the definition of the shear linear material properties of brain tissue. A comparison between human and porcine white and gray matter samples was carried out over a new large frequency range associated with both traffic road and non-penetrating ballistic impacts. Oscillatory experiments were performed by using an original custom-designed oscillatory shear testing device. The findings revealed that no significant difference occured between the linear viscoelastic behavior of the porcine and the human brain tissue. On the average, the storage modulus (G') and the loss modulus (G") of the white matter increased respectively from 2.1 +/- 0.9 kPa to 16.8 +/- 2.0 kPa and from 0.4 +/- 0.2 kPa to 18.7 +/- 2.3 kPa between 0.1 and 6300 Hz at 37 degrees C. In addition, the gray and white matter behaviors seemed to be similar at small strains. The reliability of the data and the robustness of the experimental protocol were checked using a standard rheometer (Bohlin C-VOR 150). A good agreement was found between the data obtained in the frequency and time field. As a result, the linear relaxation modulus was determined over an extensive time range (from 10(-5) s to 300 s). In a first approach, the nonlinear behavior of brain tissue was studied using stress relaxation tests. Brain tissue showed significant shear softening for strains above 1% and the time relaxation behavior was independent of the applied strain. On this basis, a visco-hyperelastic model was proposed using the generalized Maxwell model and the Ogden hyperelastic model. These models respectively describe the linear relaxation modulus and the strain dependence of the shear stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · doi:10.1097/00001199-199912000-00009 · Cited by 1,387
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
Mechanisms of mechanical signaling in development and disease
Janmey, P. A., & Miller, R. T. (2011) · Journal of Cell Science · doi:10.1242/jcs.071001 · Cited by 461
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Self-citation
Metadata
- Authors
- Nicolle, S., Lounis, M., & Willinger, R.
- Venue
- SAE Technical Paper Series
- Publisher
- SAE International
- Published
- 2004-11-01
- Volume
- 1
- Pages
- 239-58
- ISSN
- 0148-7191 (ISSN-L)
- OpenAlex
- W200778384
- Cited by
- 193
- References
- 1
- FWCI
- 6.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear Properties of Brain Tissue over a Frequency Range Relevant for Automotive Impact Situations: New Experimental Results. https://app.cochat.ai/papers/10.4271/2004-22-0011
- The paper
- Nicolle, S., Lounis, M., & Willinger, R. (2004). Shear Properties of Brain Tissue over a Frequency Range Relevant for Automotive Impact Situations: New Experimental Results. SAE Technical Paper Series. https://doi.org/10.4271/2004-22-0011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.