Arsenic removal from drinking water using granular ferric hydroxide
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper examines the use of granular ferric hydroxide (GFH) to remove both arsenate [As(V)] and arsenite [As(III)] present in drinking water by conducting batch and column studies. The kinetic studies were conducted as a function of pH, and less than 5 mg/l was achieved from an initial concentration of 100 mg/l for both As(III) and As(V) with GFH at a pH of 7.6, which is in the pH range typically encountered in drinking water supplies. In the isotherm studies, the observed data fitted well with both the Freundlich and the Langmuir models. In continuous column tests (five cycles) with tap water using GFH, consistently less than 5 mg/l of arsenic was achieved in the finished water for 38 to 42 hours of column operation, where the influent had a spiked arsenic concentration of 500 mg/l. High bed volumes (1260 and 1140) up to a breakthrough concentration of 5 mg/l were achieved in the column studies. The adsorptive capacities for GFH estimated from the column studies were higher than that of activated alumina reported in the previous studies. Speciation of a natural water sample with arsenic showed the dominance of As(III) species over As(V). Batch and column studies showed that granular ferric hydroxide (GFH) can be effectively used in small water utilities to achieve less than 5 mg As/l in drinking water. Keywords: Adsorption, Drinking water, Arsenic removal, Granular ferric hydroxide, Arsenic speciation (WaterSA: 2003 29(2): 161-170)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Granular ferric hydroxide—a new adsorbent for the removal of arsenic from natural water
Driehaus, W., Jekel, M., & Hildebrandt, U. (1998) · Journal of Water Supply: Research and Technology—AQUA · doi:10.2166/aqua.1998.0005 · Cited by 341
Characterization of arsenate adsorption on hydrous iron oxide using chemical and physical methods
Hsia, T.-H., Lo, S.-L., Lin, C.-F., & Lee, D.-Y. (1994) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)02752-8 · Cited by 192
Cited by
Shankar, S., Shanker, U., & Shikha (2014) · The Scientific World Journal · doi:10.1155/2014/304524 · Cited by 616
Yao, Y., Gao, B., Inyang, M., Zimmerman, A. R., Cao, X., Pullammanappallil, P., & Yang, L. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2011.03.006 · Cited by 608
Chowdhury, S. R., & Yanful, E. K. (2010) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.06.003 · Cited by 476
Arsenic removal by iron-modified activated carbon
Chen, W., Parette, R., Zou, J., Cannon, F. S., & Dempsey, B. A. (2007) · Water Research · doi:10.1016/j.watres.2007.01.052 · Cited by 413
Effect of competing solutes on arsenic(V) adsorption using iron and aluminum oxides
Youngran, J., FAN, M., Van Leeuwen, J., & Belczyk, J. F. (2007) · Journal of Environmental Sciences · doi:10.1016/s1001-0742(07)60151-x · Cited by 174
Metadata
- Authors
- Thirunavukkarasu, O. S., Viraraghavan, T., & Subramanian, K. S.
- Venue
- Water SA
- Publisher
- Academy of Science of South Africa
- Published
- 2003-02-01
- Volume
- 29
- Issue
- 2
- ISSN
- 0378-4738 (ISSN-L)
- OpenAlex
- W2159307979
- Cited by
- 154
- References
- 2
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.