CoChat

Secondary Analysis of an Electronic Surveillance System Combined with Multi-focal Interventions for Early Detection of Sepsis

Open access
Westra, Bonnie, Landman, Sean, Yadav, Pranjul, Steinbach, Michael · 2017 · Applied Clinical Informatics
Cited by 24

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Summary: Summary: To conduct an independent secondary analysis of a multi-focal intervention for early detection of sepsis that included implementation of change management strategies, electronic surveil-lance for sepsis, and evidence based point of care alerting using the POC AdvisorTM application. Methods: Propensity score matching was used to select subsets of the cohorts with balanced covariates. Bootstrapping was performed to build distributions of the measured difference in rates/ means. The effect of the sepsis intervention was evaluated for all patients, and High and Low Risk subgroups for illness severity. A separate analysis was performed patients on the intervention and non-intervention units (without the electronic surveillance). Sensitivity, specificity, and the positive predictive values were calculated to evaluate the accuracy of the alerting system for detecting sepsis or severe sepsis/ septic shock. Results: There was positive effect on the intervention units with sepsis electronic surveillance with an adjusted mortality rate of –6.6%. Mortality rates for non-intervention units also improved, but at a lower rate of –2.9%. Additional outcomes improved for patients on both intervention and non-intervention units for home discharge (7.5% vs 1.1%), total length of hospital stay (-0.9% vs –0.3%), and 30 day readmissions (-6.6% vs –1.6%). Patients on the intervention units showed better outcomes compared with non-intervention unit patients, and even more so for High Risk patients. The sensitivity was 95.2%, specificity of 82.0% and PPV of 50.6% for the electronic surveillance alerts. Conclusion: There was improvement over time across the hospital for patients on the intervention and non-intervention units with more improvement for sicker patients. Patients on intervention units with electronic surveillance have better outcomes; however, due to differences in exclusion criteria and types of units, further study is needed to draw a direct relationship between the electronic surveillance system and outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4338/aci-2016-07-ra-0112

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 24

Metadata

Authors
Westra, B., Landman, S., Yadav, P., & Steinbach, M.
Venue
Applied Clinical Informatics
Published
2017
Volume
26
Issue
01
Pages
47-66
ISSN
1869-0327 (ISSN-L)
OpenAlex
W2572656025
Cited by
24
References
4
FWCI
2.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Secondary Analysis of an Electronic Surveillance System Combined with Multi-focal Interventions for Early Detection of Sepsis. https://app.cochat.ai/papers/10.4338/aci-2016-07-ra-0112
The paper
Westra, B., Landman, S., Yadav, P., & Steinbach, M. (2017). Secondary Analysis of an Electronic Surveillance System Combined with Multi-focal Interventions for Early Detection of Sepsis. Applied Clinical Informatics. https://doi.org/10.4338/aci-2016-07-ra-0112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.