Green and deep eutectic solvent microextraction method for faas determination of trace level cadmium in water samples using multivariate strategic approach
Open accessAbstract
An innovative green, deep eutectic solvent microextraction (DES-ME) approach was developed for the preconcentration of trace level cadmium (Cd) in fresh canal and wastewater samples prior to flame atomic absorption spectrometry (FAAS) determination.The Cd was complexed with ammonium pyrolidine dithiocarbmate (APDC) to enhance the extraction capability in the deep eutectic solvent (DES).DES exhibits similar physico-chemical properties of the traditionally used ionic liquids, but is less costly, environmentally friendly, and offers a green alternative to conventional ionic liquid extraction.Separation of the metalenriched DES from the aqueous medium can be induced by using the Triton X-114 surfactant.The metal-enriched phase was subjected to FAAS using conventional nebulization.The multivariate strategy was applied to estimate the optimum values of the experimental factors for the recovery of metal ions under study.The results showed that the pH, volume mixing ratios of the DES, and their interaction are the most statistically significant variables.Under the optimized experimental conditions, the limit of detection was found to be 0.504 µg L -1 and the enhancement factor was 51.The validity and accuracy of proposed method were checked by the analysis of real water samples using the standard addition method and the TM-28.3Fortified Water sample.The proposed method was successfully applied to the trace level determination of Cd in canal water and wastewater samples.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The first DES used in LPME of metals was a combination of choline chloride and urea, applied as a solvent for magnetic nanoparticles and APDC in the microextraction of Pb and Cd.
“The first DES used in LPME of metals was the result of a combination of choline chloride and urea, which was applied as a solvent for magnetic nanoparticles and APDC, in the microextraction of Pb and Cd [35,36].”
From Advances in ionic liquids and deep eutectic solvents-based liquid phase microextraction of metals for sample preparation in Environmental Analytical Chemistry (2021) · cites this paper as [36]
The Introduction and Procedure for DES-ME (pages unavailable) support the use of a deep eutectic solvent with APDC to extract cadmium. But the Preparation of Deep Eutectic Solvents section specifies zinc chloride and acetamide, not choline chloride and urea. The paper does not establish that this was the first such use or describe magnetic nanoparticles or lead extraction. (LLM, conf=0.88)
Experimental — accuracy not yet measuredThe determination of metals using FAAS and ICP OES involves extract pre-dilution with water or alcohol to reduce DES phase viscosity and increase the volume available for nebulization.
“The determination of metals using FAAS [51 -53] and ICP OES [62] involves extract pre-dilution with water or alcohol to reduce the DES phase viscosity and increase the volume available for nebulization.”
From Application of deep eutectic solvents in analytical chemistry. A review (2017) · cites this paper as [51]
The Procedure for DES-ME (page not specified) says acidic ethyl alcohol was added to the viscous, metal-enriched surfactant-rich phase to decrease its viscosity before FAAS. It does not say the alcohol was added to increase the volume available for nebulization; ICP OES is attributed to a different citation in the citing sentence. (LLM, conf=0.86)
Experimental — accuracy not yet measuredWith respect to water samples, polyaromatic hydrocarbons, pesticides, and metals are the most determined analytes, with extraction procedures based on ChCl:phenol, ChCl:glycerol, ChCl:urea, ChCl:glucose and ChCl:p-chlorophenol compositions.
“With respect to water samples, polyaromatic hydrocarbons [55], pesticides [38], and metals [51,52] are the most determined analytes, with extraction procedures based on the use of ChCl:phenol, ChCl:glycerol, ChCl:urea, ChCl:glucose and ChCl: p -chlorophenol compositions.”
From Application of deep eutectic solvents in analytical chemistry. A review (2017) · cites this paper as [51]
The Conclusion reports a method for determining cadmium, a metal, in canal and wastewater samples. But the Preparation of Deep Eutectic Solvents section specifies ZnCl₂ and acetamide, not any of the listed ChCl compositions; the paper also does not establish which analytes are most commonly determined in water. (LLM, conf=0.88)
Experimental — accuracy not yet measuredDES were incorporated in the LPME of metals in 2016.
“They were incorporated in the LPME of metals in 2016 [35,36].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Still being checked.
Research works printed but not linked: 37
- [1]1. M. Žemberyová, J. Barteková, M. Závadská and M. Šišoláková. Talanta 71(4), 1661 (2007).
- [2]2. S. E. Ghazy, Sep. Sci. Techno. 30(6), 933 (1995).
- [3]3. M. B. Arain, T. G. Kazi, M. K. Jamali, N. Jalbani, H. I. Afridi, G. A. Kandhro, R. Ansari, and R. A. Sar- fraz, J. Hazard. Mater. 155(1), 216 (2008).
- [4]4. L. Järup, and A. Åkesson, Toxicol. Appl. Pharm. 238(3), 201 (2009).
- [5]5. S. E. Ghazy, Sep. Sci. Techno. 30(6), 933 (1995).
- [6]6. B. Viard, F. Pihan, S. Promeyrat, J. C. Pihan, Chemosphere, 55(10), 1349 (2004).
- [8]8. R. W. Miller, M. L. Al-Khazraji, D. R. Sisson, and D. T. Gardiner, Agric. Ecosyst. Environ. 53(2), 179 (1995).
- [9]9. N. F. Kolachi, T. G. Kazi, H. I. Afridi, N. G. Kazi, and S. Khan, Clin. Nutr. 31(6), 967 (2012).
- [10]10. Y. H. Huang, C. M. Shih, C. J. Huang, C. M. Lin, C. M. Chou, M. L. Tsai, T. P. Liu, Chiu, J. F. and C.T. Chen, J. Cell. Biochem. 98(3), 577 (2006).
- [11]11. Naeemullah, T. G. Kazi, F. Shah, H. I. Afridi, J. A. Baig, A. S. Soomro, J. AOAC Int., 96(2), 447 (2013).
- [12]12. C. Nerín, Anal. Bioanal. Chem. 388(5-6), 1001 (2007).
- [13]13. A. R. Zarei, S. Nobakht, M. A. Zaree, Journal of Trace Analysis in Food and Drugs, 1, 1 (2013).
- [14]14. S. Dadfarnia, M. Talebi, A. M. H. Shabani, and Z. Beni, Croat. Chem. Acta., 80(1), 17 (2007).
- [15]15. F. Pena-Pereira, and I. Lavilla, C. Bendicho, Spectrochim. Acta B. 64(1), 1 (2009).
- [16]16. F. Shah, T. G. Kazi, H. I. Afridi, M. B. Arain, J. A. Baig, J. Hazard. Mater. 192(3), 1132 (2011).
- [17]17. J. L. Manzoori, and G. Karim- Nezhad, Anal. Chim. Acta. 521(2), 173 (2004).
- [18]18. F. Pena-Pereira, I. Lavilla, and C. Bendicho, Trac-Trend Anal. Chem. 29(7), 617 (2010).
- [19]19. X. Han, and D. W. Armstrong, Acc. Chem. Res. 40(11), 1079 (2007).
- [20]20. E. Aguilera-Herrador, R. Lucena, S. Cárdenas, M. Valcárcel, Anal. Chim., 80(3), 793 (2008).
- [21]21. C. Capello, U. Fischer, and K. Hungerbühler, Green Chem. 9(9), 927 (2007).
- [22]22. H. Olivier-Bourbigou, and L. Magna, J. Mol. Catal. A: Chem. 182, 419 (2002).
- [23]23. D. R. MacFarlane, M. Forsyth, P. C. Howlett, J. M. Pringle, J. Sun, G. Annat, W. Neil, and E. I. Izgorod- ina, Acc. Chem. Res. 40(11), 1165 (2007).
- [24]24. Q. Zhang, K. D. O. Vigier, S., Royer, and F. Jérôme, Chem. Soc. Rev. 41(21), 7108 (2012).
- [25]25. D. Carriazo, M. C. Serrano, M. C. Gutiérrez, M. L. Ferrer, and F. del Monte, Chem. Soc. Rev. 41(14), 4996 (2012).
- [26]26. B. Tang, and K. H. Row, Monatsh. Chem. 144(10), 1427 (2013).
- [27]27. E. L. Smith, A. P. Abbott, and K. S. Ryder, Chem. Rev. 114(21), 11060 (2014).
- [28]28. B. Tang, H. Zhang, and K. H. Row, Separ. Sci, 38(6), 1053 (2015).
- [29]29. Q. Zeng, Y. Wang, Y. Huang, X. Ding, J. Chen, and K. Xu, Analyst 139(10), 2565 (2014).
- [30]30. Q. Zhang, K. D. O. Vigier, S. Royer, and F. Jérôme, Chem. Soc. Rev. 41(21), 7108 (2012).
- [31]31. M. Francisco, A. van den Bruinhorst, and M. C. Kroon, Angew. Chem. Int. Ed. 52(11), 3074 (2013).
- [32]32. J. D. Mota Morales, M. C. Gutiér- rez, M. L. Ferrer, I. C. Sanchez, E. A. Elizalde Peña, J. A. Pojman, D. L. Francisco, and G. Luna Bárcenas, J. Polym. Sci. A Polym. Chem. 51(8), 1767 (2013).
- [33]33. M. A. Chamjangali, S. T. Farooji, and B. Bahramian, J. Hazard. Mater. 174(1), 843 (2010).
- [34]34. S. Dadfarnia, A. M. H. Shabani, and E. Kamranzadeh, Talanta 79(4), 1061 (2009).
- [35]35. J. L. Manzoori, and A. Bavili-Tabrizi, Anal. Chim. Acta 470(2), 215 (2002).
- [36]36. A. N. Anthemidis, G. A. Zachari- adis, C. G., Farastelis, and J. A. Stratis, Talanta 62(3), 437 (2004).
- [37]37. J. J. Ma, X. Du, J. W. Zhang, J. C. Li, and L. Z. Wang, Talanta 80(2), 980 (2009).
- [38]38. E. Yilmaz, and M. Soylak, Anal. Chim. Acta. 886, 75 (2015).
Cited by
Sorted by citations
Application of deep eutectic solvents in analytical chemistry. A review
Shishov, A., Bulatov, A., Locatelli, M., Carradori, S., & Andruch, V. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.07.015 · Cited by 561 · see citing works
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116398 · Cited by 86 · see citing works
Green microextraction methodologies for sample preparations
Kokosa, J. M., & Przyjazny, A. (2022) · Green Analytical Chemistry · doi:10.1016/j.greeac.2022.100023 · Cited by 86 · see citing works
Khalid, A., Tahir, S., Khalid, A. R., Hanif, M. A., Abbas, Q., & Zahid, M. (2024) · Green Chemistry · doi:10.1039/d3gc04112c · Cited by 73 · see citing works
Ullah, N., Haseeb, A., & Tüzen, M. (2023) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2023.2197495 · Cited by 56 · see citing works
Application of deep eutectic solvents in the pre-processing of atomic spectrometry analysis
Yang, X.-F., Yan, C., Sun, Y.-P., Liu, Y., Yang, S., Deng, Q., Tan, Z.-Q., & Wen, X.-D. (2022) · Trends in Analytical Chemistry (TrAC) · doi:10.1016/j.trac.2022.116555 · Cited by 20 · see citing works
Suljkanović, M., Suljagić, J., Bjelić, E., Prkić, A., & Bošković, P. (2024) · Molecules · doi:10.3390/molecules29092122 · Cited by 25 · see citing works
Rečlo, M., Yılmaz, E., Bazeľ, Y., & Soylak, M. (2017) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2017.1413185 · Cited by 25 · see citing works
Zhu, G., Chen, Y., Wang, S., & Yang, X. (2025) · Separation and Purification Technology · doi:10.1016/j.seppur.2025.133382 · Cited by 16 · see citing works
Application of Deep Eutectic Solvents for the Determination of Inorganic Analytes
Andruch, V., Vojteková, V., Kalyniukova, A., Zengin, G., Hagarová, I., & Yordanova, T. (2025) · Advances in Sample Preparation · doi:10.1016/j.sampre.2025.100158 · Cited by 14 · see citing works
Deep eutectic solvents in microextraction
Alshana, U., & Soylak, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822139-6.00019-5 · Cited by 12 · see citing works
- Authors
- Tuzen, M.
- Venue
- Atomic Spectroscopy
- Publisher
- Atomic Spectroscopy Press Limited
- Published
- 2016-12-25
- Volume
- 37
- Issue
- 6
- Pages
- 244-251
- ISSN
- 0195-5373 (ISSN-L)
- 2708-521X
- OpenAlex
- W3047960684
- Cited by
- 11
- References
- 0
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2017: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Atomic Spectroscopy (publishedVersion)
- Funders
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
- Türkiye Bilimler Akademisi
- Gaziosmanpasa Üniversitesi
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
- Keywords
- cadmium determination, deep eutectic solvents, green extraction, microextraction, pyrrolidine dithiocarbamate, multivariate optimization, trace metal preconcentration, canal water, wastewater, flame atomic absorption spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review