Symmetrical multilevel converters with two quadrant DC-DC feeding
Open accessThe DOI matches its OpenAlex record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Krismer, F., & Kolar, J. W. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2027904 · Cited by 421
Isolated DC/DC Structure Based on Modular Multilevel Converter
Kenzelmann, S., Rufer, A., Dujic, D., Canales, F., & de Novaes, Y. R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305976 · Cited by 371
Zhou, H., & Khambadkone, A. M. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2023493 · Cited by 283
Performance optimization of a high current dual active bridge with a wide operating voltage range
Krismer, F., Round, S., & Kolar, J. W. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712096 · Cited by 276
Minimum Current Operation of Bidirectional Dual-Bridge Series Resonant DC/DC Converters
Corradini, L., Seltzer, D., Bloomquist, D., Zane, R., Maksimović, D., & Jacobson, B. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2181421 · Cited by 247
“An extensive review of modulation techniques for high-power DAB converters is provided in [18].”
BackgroundWeise, N. D., Castelino, G., Basu, K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293112 · Cited by 223
“It is possible to overcome these difficulties by modulating the duty cycles of both the bridges [20] [21].”
BackgroundCirculating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“This is also the case for preliminary TPS methods including triangular and trapezoidal modulation methods, whose name comes from the inductor current shape [50], [51], [59], [60].”
BackgroundMethodMultilevel Converter for Traction Applications: Small-Scale Prototype Tests Results
Carpita, M., Marchesoni, M., Pellerin, M., & Moser, D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918645 · Cited by 100
“ing the soft commutation of the cycloconverter because the overlap time reduces the available voltage at the output [15].”
BackgroundDetails and implementation of a SiC-based solid state transformer prototype
Ramirez, J. M., Barrios, R. A., & Salome, B. J. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2017.8126690 · Cited by 6
“This modulation method offers the following advantages [17]-[18]: (i) highest power transfer; (ii) lowest RMS circuit current compared to other modulation methods; (iii) low control complexity; (iv) zero voltage switching during the switches’ turn-on; (v) a symmetrical share of the losses on all switches.”
Background
Metadata
- Authors
- Schibli, N.
- Venue
- reroDoc Digital Library
- Publisher
- European Organization for Nuclear Research
- Published
- 2000-01-01
- OpenAlex
- W1494319207
- Cited by
- 126
- References
- 0
- Type
- dissertation
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.