The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A radiomics nomogram for preoperative prediction of microvascular invasion risk in hepatitis B virus-related hepatocellular carcinoma
Open accessAbstract
PURPOSE: We aimed to develop and validate a radiomics nomogram for preoperative prediction of microvascular invasion (MVI) in hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). METHODS: A total of 304 eligible patients with HCC were randomly divided into training (n=184) and independent validation (n=120) cohorts. Portal venous and arterial phase computed tomography data of the HCCs were collected to extract radiomic features. Using the least absolute shrinkage and selection operator algorithm, the training set was processed to reduce data dimensions, feature selection, and construction of a radiomics signature. Then, a prediction model including the radiomics signature, radiologic features, and alpha-fetoprotein (AFP) level, as presented in a radiomics nomogram, was developed using multivariable logistic regression analysis. The radiomics nomogram was analyzed based on its discrimination ability, calibration, and clinical usefulness. Internal cohort data were validated using the radiomics nomogram. RESULTS: The radiomics signature was significantly associated with MVI status (P < 0.001, both cohorts). Predictors, including the radiomics signature, nonsmooth tumor margin, hypoattenuating halos, internal arteries, and alpha-fetoprotein level were reserved in the individualized prediction nomogram. The model exhibited good calibration and discrimination in the training and validation cohorts (C-index [95% confidence interval]: 0.846 [0.787-0.905] and 0.844 [0.774-0.915], respectively). Its clinical usefulness was confirmed using a decision curve analysis. CONCLUSION: The radiomics nomogram, as a noninvasive preoperative prediction method, shows a favorable predictive accuracy for MVI status in patients with HBV-related HCC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
A deep learning-based radiomics model for prediction of survival in glioblastoma multiforme
Lao, J., Chen, Y., Li, Z.-C., Li, Q., Zhang, J., Liu, J., & Zhai, G. (2017) · Scientific Reports · doi:10.1038/s41598-017-10649-8 · Cited by 630
Self-citationKuo, M. D., Gollub, J., Sirlin, C. B., Ooi, C., & Chen, X. (2007) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2007.04.031 · Cited by 168
Cited by
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Guidelines for the Diagnosis and Treatment of Hepatocellular Carcinoma (2019 Edition)
Zhou, J., Sun, H., Wang, Z., Cong, W., Wang, J., Zeng, M., Zhou, W., Bie, P., Liu, L., Wen, T., et al. (2020) · Liver Cancer · doi:10.1159/000509424 · Cited by 800
Self-citationXu, X., Zhang, H.-L., Liu, Q.-P., Sun, S.-W., Zhang, J., Zhu, F.-P., Yang, G., Yan, X., Zhang, Y.-D., & Liu, X.-S. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2019.02.023 · Cited by 706
Self-citationRadiomics with artificial intelligence: a practical guide for beginners
Department of Radiology Istanbul Training and Research Hospital, I., Kocak, B., Durmaz, E. S., Department of Radiology, B. M. S. S. H., Ates, E., Department of Radiology Istanbul Training and Research Hospital, I., Kilickesmez, O., & Department of Radiology Istanbul Training and Research Hospital, I. (2019) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2019.19321 · Cited by 366
From Handcrafted to Deep-Learning-Based Cancer Radiomics: Challenges and Opportunities
Afshar, P., Mohammadi, A., Plataniotis, K. N., Oikonomou, A., & Benali, H. (2019) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2900993 · Cited by 294
Metadata
- Authors
- Hepatology Unit and Department of Infectious Diseases, N. H., Peng, J., Zhang, J., Hepatology Unit and Department of Infectious Diseases, N. H., Zhang, Q., Department of Hepatobiliary Surgery, N. H., Xu, Y., Department of Medical Imaging Center, N. H., Zhou, J., Department of Hepatobiliary Surgery, N. H., Liu, L., & Hepatology Unit and Department of Infectious Diseases, N. H.
- Venue
- Diagnostic and Interventional Radiology
- Publisher
- Galenos Yayinevi
- Published
- 2018-06-05
- Volume
- 24
- Issue
- 3
- Pages
- 121-127
- ISSN
- 1300-4360 (ISSN-L)
- 1305-3612
- OpenAlex
- W2805601297
- Cited by
- 179
- References
- 4
- FWCI
- 16.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.