Variability of levels and composition of PM 10 and PM 2.5 in the Barcelona metro system
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
From an environmental perspective, the underground metro system is one of the cleanest forms of public transportation in urban agglomerations. Current studies report contradicting results regarding air quality in the metro systems: whereas some reveal poor air quality, others report PM levels which are lower or of the same order of magnitude than those measured in traffic sites above ground level. The present work assesses summer and winter indoor air quality and passenger exposure in the Barcelona metro, focusing on PM levels and their metal contents. In addition, the impact on indoor air quality of platform screen door systems (automated systems consisting of closed rail track and platforms) is evaluated, to determine whether these systems reduce passenger exposure to PM when compared with conventional systems (open tracks and platforms). In the Barcelona metro PM levels inside the trains in summer are amongst the lowest reported for worldwide metro systems (11–32 μg m−3 PM2.5). This is most likely due to the air conditioning system working in all carriages of the Barcelona metro during the whole year. Levels were considerably higher on the platforms, reaching mean levels of 46 and 125 μg m3 in the new (L9) and old (L3) lines, respectively. PM10 data are also reported in the present study, but comparison with other metro systems is difficult due to the scarcity of data compared with PM2.5. Results showed distinct PM daily cycles, with a drastic increase from 06:00 to 07:00 a.m., a diurnal maximum from 07:00 to 10:00 p.m., and marked decrease between 10:00 p.m. and 05:00 a.m. The elements with the highest enrichment were those associated with wheel or brake abrasion products (Ba, Fe, Cu, Mn, Cr, Sb, As, Mo, Co, Sr, among others). Laminar hematite (Fe2O3) was the dominant particle type, being mainly originated by mechanical abrasion of the rail track and wheels. Regarding passenger exposure to PM, the contribution of commuting by metro was estimated to account for around 10% of the daily exposure. However, this contribution may be one order of magnitude higher when specific matals are considered. Finally, we conclude that the implementation of platform screen door systems results in reductions of both PM levels and metal concentrations. In addition an advanced optimized ventilation system gave even a much higher efficiency in reducing exposure to PM of metro commuters. Combining these two features PM exposure levels in the platforms may be reduced down by a factor of 7 with respect the old subway lines in Barcelona.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Composition of the Continental Crust
Rudnick, R. L., & Gao, S. (2014) · Treatise on Geochemistry · doi:10.1016/b978-0-08-095975-7.00301-6 · Cited by 5,691
Composition of the Continental Crust
Rudnick, R. L., & Gao, S. (2003) · Treatise on Geochemistry · doi:10.1016/b0-08-043751-6/03016-4 · Cited by 3,413
Cavalli, F., Viana, M., Yttri, K. E., Genberg, J., & Putaud, J.-P. (2010) · Atmospheric Measurement Techniques · doi:10.5194/amt-3-79-2010 · Cited by 965 · cited 2×
“A third portion of filter was used for the analysis of organic (OC) and elemental carbon (EC) by means of thermo-optical methods by means of a laboratory OCEC Sunset instrument using the protocol EUSAAR-2 (Cavalli et al., 2010). 20 Laboratory blank filters were analyzed following the same methodology and concentration…”
MethodSelf-citationMetal emissions from road traffic and the influence of resuspension—results from two tunnel studies
Sternbeck, J., Sjödin, Å., & Andréasson, K. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00561-7 · Cited by 815 · cited 1×
“Barite is very often used as a bulk material (as mineral filler) for the fabrication of brakes in trains and road vehicles (Sternbeck et al., 2002; Aarnio et al., 2005).”
BackgroundChow, J. C., Watson, J. G., Chen, L.-W. A., Arnott, W. P., Moosmüller, H., & Fung, K. (2004) · Environmental Science & Technology · doi:10.1021/es034936u · Cited by 652 · cited 3×
“Concerning the OC and EC contributions, although we measured EC and OC separately with a thermo-optical method, it is possible that Fe2O3 may act as a catalyser for EC oxidation at relatively low temperatures when the Fe 2O3/EC ratio is very high (Chow et al., 2004).”
MethodInfluentialExposure to particulate matter in traffic: A comparison of cyclists and car passengers
Int Panis, L., de Geus, B., Vandenbulcke, G., Willems, H., Degraeuwe, B., Bleux, N., Mishra, V., Thomas, I., & Meeusen, R. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.04.028 · Cited by 394 · cited 1×
“Johansson and Johansson (2003) evaluated the effect of washing railways and walls in tunnels on abatement of PM levels at the Stockholm underground, identifying a decrease of around 13 % of the PM 2.”
BackgroundKarlsson, H. L., Nilsson, L., & Möller, L. (2005) · Chemical Research in Toxicology · doi:10.1021/tx049723c · Cited by 337 · cited 1×
“…the levels of PM and metals (Fromme et al., 1998; Adams et al., 2001a and b; Furuya et al., 2001; Award, 2002; Seaton et al., 2005; Johansson and Johansson, 2003; Karlsson et al., 2005; Aarnio et al., 2005; Cheng et al., 2008; Ye et al., 2010; Cheng and Yan, 2011; Kam et al., 2011, among others).”
BackgroundThe London Underground: dust and hazards to health
Seaton, A., Cherrie, J., Dennekamp, M., Donaldson, K., Hurley, J. F., & Tran, C. L. (2005) · Occupational and Environmental Medicine · doi:10.1136/oem.2004.014332 · Cited by 282 · cited 4×
“…metro systems, especially concerning the levels of PM and metals (Fromme et al., 1998; Adams et al., 2001a and b; Furuya et al., 2001; Award, 2002; Seaton et al., 2005; Johansson and Johansson, 2003; Karlsson et al., 2005; Aarnio et al., 2005; Cheng et al., 2008; Ye et al., 2010; Cheng and Yan,…”
BackgroundResultInfluentialPartitioning of major and trace components in PM10–PM2.5–PM1 at an urban site in Southern Europe
Pérez, N., Pey, J., Querol, X., Alastuey, A., López, J. M., & Viana, M. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.11.034 · Cited by 266 · cited 1×
“Both sulphate and nitrate levels fall in the range of typical summer outdoor levels in Barcelona, whereas in winter, sulphate levels are markedly reduced and nitrate slightly increased (Pérez et al., 2008).”
BackgroundSelf-citationNieuwenhuijsen, M. J., Gómez-Perales, J. E., & Colvile, R. N. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.08.002 · Cited by 249 · cited 7×
“Its red line (L1) started operating in 1924 (after London, Budapest, Paris, Stockholm, Madrid, among others).”
BackgroundResultInfluentialKam, W., Cheung, K., Daher, N., & Sioutas, C. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.12.049 · Cited by 233 · cited 4×
“This is due to the following: (a) the system is usually based on electric trains (with low emissions); (b) it can transport a large number of passengers, up to nearly 7 million passengers/day in the case of Tokyo, nearly 5 million/day in New York and Mexico, or 3 million in London (Nieuwenhuijsen et al., 2007), making…”
BackgroundResultInfluentialConcentrations and properties of airborne particles in the Mexico City subway system
Mugica-Álvarez, V., Figueroa-Lara, J., Romero-Romo, M., Sepúlveda-Sánchez, J., & López-Moreno, T. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.11.038 · Cited by 176 · cited 2×
“Other studies performed in metro systems, such as Tokyo, Taipei, Helsinki, México, Hong Kong, Guanzhou, Los Angeles and New York (Furuya et al., 2001; Cheng et al., 2008; Cheng and Yan, 2011; Aarnio et al., 2005; Gómez-Perales 10 et al., 2004, 2007; Mugica-Álvarez et al., 2012; Chan et al., 2002a, b; Kam et al., 2011;…”
BackgroundMcNabola, A., Broderick, B., & Gill, L. W. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.04.015 · Cited by 175
Levels of PM10 and PM2.5 in Taipei Rapid Transit System
Cheng, Y., Lin, Y.-L., & Liu, C. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.07.011 · Cited by 164 · cited 3×
“Other studies performed in metro systems, such as Tokyo, Taipei, Helsinki, México, Hong Kong, Guanzhou, Los Angeles and New York (Furuya et al., 2001; Cheng et al., 2008; Cheng and Yan, 2011; Aarnio et al., 2005; Gómez-Perales 10 et al., 2004, 2007; Mugica-Álvarez et al., 2012; Chan et al., 2002a, b; Kam et al., 2011;…”
BackgroundMechanisms Related to the Genotoxicity of Particles in the Subway and from Other Sources
Karlsson, H. L., Holgersson, Å., & Möller, L. (2008) · Chemical Research in Toxicology · doi:10.1021/tx7003568 · Cited by 152
Characterisation of airborne particles in London by computer-controlled scanning electron microscopy
Sitzmann, B., Kendall, M., Watt, J., & Williams, I. D. (1999) · The Science of The Total Environment · doi:10.1016/s0048-9697(99)00326-5 · Cited by 151 · cited 1×
“Older studies have shown a higher contribution of silicate particles (e.g. Sitzmann et al., 1999), but more modern results also show the prevalence of Fe-rich particles (Salma, 2009; Salma et al., 2009).”
ResultRaut, J., Chazette, P., & Fortain, A. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.10.038 · Cited by 146
Comparisons of commuter's exposure to particulate matters while using different transportation modes
Tsai, D.-H., Wu, Y.-H., & Chan, C. (2008) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2008.06.016 · Cited by 133 · cited 1×
“Also during metro commuting, abrasion, sparking and resuspension products may cause high exposure levels to PM higher or lower than those reached during surface commuting (Adams et al., 2001a; Chan et al., 2002a and b; Aarnio et al., 2005; Ǵomez-Perales et al., 2007; Tsai et al., 2008).”
BackgroundChillrud, S. N., Grass, D., Ross, J. M., Coulibaly, D., Slavkovich, V., Epstein, D., Sax, S. N., Pederson, D., Johnson, D., Spengler, J. D., et al. (2005) · Journal of Urban Health · doi:10.1093/jurban/jti006 · Cited by 103
Environmental Study in Subway Metro Stations in Cairo, Egypt
Awad, A. H. A. (2002) · Journal of Occupational Health · doi:10.1539/joh.44.112 · Cited by 90 · cited 1×
“…in the metro systems, especially concerning the levels of PM and metals (Fromme et al., 1998; Adams et al., 2001a and b; Furuya et al., 2001; Award, 2002; Seaton et al., 2005; Johansson and Johansson, 2003; Karlsson et al., 2005; Aarnio et al., 2005; Cheng et al., 2008; Ye et al., 2010;…”
BackgroundEscrig, A., Monfort, E., Celades, I., Querol, X., Amato, F., Minguillón, M. C., & Hopke, P. K. (2009) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.59.11.1296 · Cited by 87 · cited 1×
“Concentration uncertainties were estimated as described by Escrig et al. (2009).”
MethodSelf-citationCheng, Y., & Yan, J.-W. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.06.011 · Cited by 81 · cited 1×
“…the levels of PM and metals (Fromme et al., 1998; Adams et al., 2001a and b; Furuya et al., 2001; Award, 2002; Seaton et al., 2005; Johansson and Johansson, 2003; Karlsson et al., 2005; Aarnio et al., 2005; Cheng et al., 2008; Ye et al., 2010; Cheng and Yan, 2011; Kam et al., 2011, among others).”
BackgroundDust exposure in Munich public transportation: a comprehensive 4-year survey in buses and trams
Praml, G., & Schierl, R. (2000) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050029 · Cited by 80
Murruni, L., Solanes, V., Debray, M. E., Kreiner, A. J., Davidson, J., Davidson, M., Vázquez, M. E., & Ozafrán, M. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.06.025 · Cited by 77
Boudia, N., Halley, R., Kennedy, G. G., Lambert, J., Gareau, L., & Zayed, J. (2005) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2005.09.094 · Cited by 65
Fine particle concentrations in buses and taxis in Florence, Italy
Fondelli, M. C., Chellini, E., Yli‐Tuomi, T., Cenni, I., Gasparrini, A., Nava, S., García-Orellana, I., Lupi, A., Grechi, D., Mallone, S., et al. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.07.054 · Cited by 62
New Directions: Science and policy – Out of step on NOx and NO2?
Williams, M. L., & Carslaw, D. C. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.04.067 · Cited by 59
Personal, indoor and outdoor air pollution levels among pregnant women
Schembari, A., Mas, M. T., de Nazelle, A. J., Dadvand, P., Vrijheid, M., Cirach, M., Martinez, D. R., Figueras, F., Querol, X., Basagaña, X., et al. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.09.053 · Cited by 58
Self-citationAir Pollution in Underground Railway Systems
Salma, I. (2009) · Royal Society of Chemistry eBooks · doi:10.1039/9781847559654-00065 · Cited by 16
Jacquemin, B., Lanki, T., Sunyer, J., Cabrera, L., Querol, X., Bellander, T., Moreno, N., Peters, A., Pey, J., & Pekkanen, J. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.10.007 · Cited by 13
Self-citation
Cited by
Airborne, Vehicle-Derived Fe-Bearing Nanoparticles in the Urban Environment: A Review
Gonet, T., & Maher, B. A. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b01505 · Cited by 202
Factors controlling air quality in different European subway systems
Martins, V., Moreno, T., Mendes, L., Eleftheriadis, K., Diapouli, E., Alves, C. A., Duarte, M., de Miguel, E., Capdevila, M., Querol, X., et al. (2016) · Environmental Research · doi:10.1016/j.envres.2015.12.007 · Cited by 194
Self-citationAir quality inside subway metro indoor environment worldwide: A review
Xu, B., & Hao, J. (2017) · Environment International · doi:10.1016/j.envint.2017.06.016 · Cited by 167
Metadata
- Authors
- Querol, X., Moreno, T., Karanasiou, A., Reche, C., Alastuey, A., Viana, M., Font, O., Gil, J., de Miguel, E., & Capdevila, M.
- Venue
- Atmospheric Chemistry and Physics
- Publisher
- Copernicus GmbH
- Published
- 2012-06-08
- Volume
- 12
- Issue
- 11
- Pages
- 5055-5076
- ISSN
- 1680-7316 (ISSN-L)
- 1680-7324
- OpenAlex
- W2034571346
- Cited by
- 222
- References
- 30
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.