Cited by 238Atmospheric and Environmental Gas DynamicsSpectroscopy and Laser ApplicationsCalibration and Measurement Techniques

Building the COllaborative Carbon Column Observing Network (COCCON): long-term stability and ensemble performance of the EM27/SUN Fourier transform spectrometer

Open access
Frey, Matthias, Sha, Mahesh K., Hase, Frank, Kiel, Matthäus, Blumenstock, Thomas, Harig, Roland, Surawicz, Gregor, Deutscher, Nicholas M. +16 more·2019·Atmospheric Measurement Techniques

Published version of a preprint

Abstract

In a 3.5-year long study, the long-term performance of a mobile, solar absorption Bruker EM27/SUN spectrometer, used for greenhouse gas observations, is checked with respect to a co-located reference Bruker IFS 125HR spectrometer, which is part of the Total Carbon Column Observing Network (TCCON). We find that the EM27/SUN is stable on timescales of several years; the drift per year between the EM27/SUN and the official TCCON product is 0.02 ppmv for XCO 2 and 0.9 ppbv for XCH 4 , which is within the 1 σ precision of the comparison, 0.6 ppmv for XCO 2 and 4.3 ppbv for XCH 4 . The bias between the two data sets is 3.9 ppmv for XCO 2 and 13.0 ppbv for XCH 4 . In order to avoid sensitivity-dependent artifacts, the EM27/SUN is also compared to a truncated IFS 125HR data set derived from full-resolution TCCON interferograms. The drift is 0.02 ppmv for XCO 2 and 0.2 ppbv for XCH 4 per year, with 1 σ precisions of 0.4 ppmv for XCO 2 and 1.4 ppbv for XCH 4 , respectively. The bias between the two data sets is 0.6 ppmv for XCO 2 and 0.5 ppbv for XCH 4 . With the presented long-term stability, the EM27/SUN qualifies as an useful supplement to the existing TCCON network in remote areas. To achieve consistent performance, such an extension requires careful testing of any spectrometers involved by application of common quality assurance measures. One major aim of the COllaborative Carbon Column Observing Network (COCCON) infrastructure is to provide these services to all EM27/SUN operators. In the framework of COCCON development, the performance of an ensemble of 30 EM27/SUN spectrometers was tested and found to be very uniform, enhanced by the centralized inspection performed at the Karlsruhe Institute of Technology prior to deployment. Taking into account measured instrumental line shape parameters for each spectrometer, the resulting average bias across the ensemble with respect to the reference EM27/SUN used in the long-term study in XCO 2 is 0.20 ppmv, while it is 0.8 ppbv for XCH 4 . The average standard deviation of the ensemble is 0.13 ppmv for XCO 2 and 0.6 ppbv for XCH 4 . In addition to the robust metric based on absolute differences, we calculate the standard deviation among the empirical calibration factors. The resulting 2 σ uncertainty is 0.6 ppmv for XCO 2 and 2.2 ppbv for XCH 4 . As indicated by the executed long-term study on one device presented here, the remaining empirical calibration factor deduced for each individual instrument can be assumed constant over time. Therefore the application of these empirical factors is expected to further improve the EM27/SUN network conformity beyond the scatter among the empirical calibration factors reported above.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5194/amt-12-1513-2019

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 37

  1. Davis, S., Abrams, M. C., and Brault, J. W.: Fourier Transform Spectrometry, Academic press, 190-198, 2010.
  2. Dietrich, F. and Chen, J.: Portable Automated Enclo- sure for a Spectrometer Measuring Greenhouse Gases, Geophys. Res. Abstracts, 20, EGU2018-16281-1, https://doi.org/10.13140/RG.2.2.11591.14248, 2018. · DOI
  3. Dlugokencky, E. J., Masarie, K. A., Tans, P. P., Conway, T. J., and Xiong, X.: Is the amplitude of the methane seasonal cycle changing?, Atmos. Environ., 31, 21-26, https://doi.org/10.1016/S1352-2310(96)00174-4, 1997. · DOI
  4. Dohe, S.: Measurements of atmospheric CO 2 columns using ground-based FTIR spectra, Ph.D. thesis, Karlsruhe Institute of Technology, 2013.
  5. Frankenberg, C., Pollock, R., Lee, R. A. M., Rosenberg, R., Blavier, J.-F., Crisp, D., O'Dell, C. W., Osterman, G. B., Roehl, C., Wennberg, P. O., and Wunch, D.: The Orbiting Carbon Observa- tory (OCO-2): spectrometer performance evaluation using pre- launch direct sun measurements, Atmos. Meas. Tech., 8, 301- 313, https://doi.org/10.5194/amt-8-301-2015, 2015. · DOI
  6. Frey, M., Hase, F., Blumenstock, T., Groß, J., Kiel, M., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Calibration and instrumental line shape characterization of a set of portable FTIR spectrometers for detecting greenhouse gas emissions, At- mos. Meas. Tech., 8, 3047-3057, https://doi.org/10.5194/amt-8- 3047-2015, 2015. · DOI
  7. Geibel, M. C., Messerschmidt, J., Gerbig, C., Blumenstock, T., Chen, H., Hase, F., Kolle, O., Lavric, J. V., Notholt, J., Palm, M., Rettinger, M., Schmidt, M., Sussmann, R., Warneke, T., and Feist, D. G.: Calibration of column-averaged CH 4 over Euro- pean TCCON FTS sites with airborne in-situ measurements, At- mos. Chem. Phys., 12, 8763-8775, https://doi.org/10.5194/acp- 12-8763-2012, 2012. · DOI
  8. Gisi, M., Hase, F., Dohe, S., and Blumenstock, T.: Camtracker: a new camera controlled high precision solar tracker sys- tem for FTIR-spectrometers, Atmos. Meas. Tech., 4, 47-54, https://doi.org/10.5194/amt-4-47-2011, 2011. · DOI
  9. Gisi, M., Hase, F., Dohe, S., Blumenstock, T., Simon, A., and Keens, A.: XCO 2 -measurements with a tabletop FTS using so- lar absorption spectroscopy, Atmos. Meas. Tech., 5, 2969-2980, https://doi.org/10.5194/amt-5-2969-2012, 2012. · DOI
  10. Hase, F.: Improved instrumental line shape monitoring for the ground-based, high-resolution FTIR spectrometers of the Net- work for the Detection of Atmospheric Composition Change, Atmos. Meas. Tech., 5, 603-610, https://doi.org/10.5194/amt-5- 603-2012, 2012. · DOI
  11. Hase, F., Blumenstock, T., and Paton-Walsh, C.: Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software, Appl. Opt., 38, 3417-3422, https://doi.org/10.1364/AO.38.003417, 1999. · DOI
  12. Hase, F., Drouin, B. J., Roehl, C. M., Toon, G. C., Wennberg, P. O., Wunch, D., Blumenstock, T., Desmet, F., Feist, D. G., Heikkinen, P., De Mazière, M., Rettinger, M., Robinson, J., Schneider, M., Sherlock, V., Sussmann, R., Té, Y., Warneke, T., and Weinzierl, C.: Calibration of sealed HCl cells used for TCCON instrumen- tal line shape monitoring, Atmos. Meas. Tech., 6, 3527-3537, https://doi.org/10.5194/amt-6-3527-2013, 2013. · DOI
  13. Hase, F., Blumenstock, T., Dohe, S., Gross, J., and Kiel, M.: TCCON data from Karlsruhe (DE), ReleaseGGG2014R1, TCCON data archive, hosted by CaltechDATA, https://doi.org/10.14291/tccon.ggg2014.karlsruhe01.R1/1182416 (last access: 4 March 2019), 2014. · DOI
  14. Hase, F., Frey, M., Blumenstock, T., Groß, J., Kiel, M., Kohlhepp, R., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Application of portable FTIR spectrometers for detecting green- house gas emissions of the major city Berlin, Atmos. Meas. Tech., 8, 3059-3068, https://doi.org/10.5194/amt-8-3059-2015, 2015. · DOI
  15. Hedelius, J. K., Viatte, C., Wunch, D., Roehl, C. M., Toon, G. C., Chen, J., Jones, T., Wofsy, S. C., Franklin, J. E., Parker, H., Dubey, M. K., and Wennberg, P. O.: Assessment of errors and biases in retrievals of XCO 2 , XCH 4 , XCO, and XN 2 O from a 0.5 cm -1 resolution solar-viewing spectrometer, Atmos. Meas. Tech., 9, 3527-3546, https://doi.org/10.5194/amt-9-3527-2016, 2016. · DOI · Paper page
  16. Hedelius, J. K., Parker, H., Wunch, D., Roehl, C. M., Viatte, C., Newman, S., Toon, G. C., Podolske, J. R., Hillyard, P. W., Iraci, L. T., Dubey, M. K., and Wennberg, P. O.: Intercomparability of XCO 2 and XCH 4 from the United States TCCON sites, At- mos. Meas. Tech., 10, 1481-1493, https://doi.org/10.5194/amt- 10-1481-2017, 2017 · DOI
  17. Heinle, L. and Chen, J.: Automated enclosure and protec- tion system for compact solar-tracking spectrometers, Atmos. Meas. Tech., 11, 2173-2185, https://doi.org/10.5194/amt-11- 2173-2018, 2018. · DOI
  18. Kalnay, E., Kanamitsu, M., Kistler, R., Collins, W., Deaven, D., Gandin, L., Iredell, M., Saha, S., White, G., Woollen, J., Zhu, Y., Leetmaa, A., Reynolds, R., Chelliah, M., Ebisuzaki, W., Higgins, W., Janowiak, J., Mo, K. C., Ropelewski, C., Wang, J., Jenne, R., and Joseph, D.: The NCEP/NCAR 40-Year Reanalysis Project, Bull. Am. Meteorol. Soc., 77, 437-471, https://doi.org/10.1175/1520- 0477(1996)077<0437:TNYRP>2.0.CO;2, 1996. · DOI
  19. Keppel-Aleks, G., Toon, G. C., Wennberg, P. O., and Deutscher, N. M.: Reducing the impact of source brightness fluctuations on spectra obtained by Fourier-transform spectrometry, Appl. Opt., 46, 4774-4779, https://doi.org/10.1364/AO.46.004774, 2007. · DOI
  20. Kiel, M., Hase, F., Blumenstock, T., and Kirner, O.: Comparison of XCO abundances from the Total Carbon Column Observing Net- work and the Network for the Detection of Atmospheric Compo- sition Change measured in Karlsruhe, Atmos. Meas. Tech., 9, 2223-2239, https://doi.org/10.5194/amt-9-2223-2016, 2016a. · DOI
  21. Kiel, M., Wunch, D., Wennberg, P. O., Toon, G. C., Hase, F., and Blumenstock, T.: Improved retrieval of gas abun- dances from near-infrared solar FTIR spectra measured at the Karlsruhe TCCON station, Atmos. Meas. Tech., 9, 669-682, https://doi.org/10.5194/amt-9-669-2016, 2016b. · DOI
  22. Klappenbach, F., Bertleff, M., Kostinek, J., Hase, F., Blumenstock, T., Agusti-Panareda, A., Razinger, M., and Butz, A.: Accurate mobile remote sensing of XCO 2 and XCH 4 latitudinal transects from aboard a research vessel, Atmos. Meas. Tech., 8, 5023- 5038, https://doi.org/10.5194/amt-8-5023-2015, 2015. · DOI
  23. Messerschmidt, J., Geibel, M. C., Blumenstock, T., Chen, H., Deutscher, N. M., Engel, A., Feist, D. G., Gerbig, C., Gisi, M., Hase, F., Katrynski, K., Kolle, O., Lavrič, J. V., Notholt, J., Palm, M., Ramonet, M., Rettinger, M., Schmidt, M., Suss- mann, R., Toon, G. C., Truong, F., Warneke, T., Wennberg, P. O., Wunch, D., and Xueref-Remy, I.: Calibration of TCCON column-averaged CO 2 : the first aircraft campaign over Euro- pean TCCON sites, Atmos. Chem. Phys., 11, 10765-10777, https://doi.org/10.5194/acp-11-10765-2011, 2011. · DOI
  24. Morino, I., Uchino, O., Inoue, M., Yoshida, Y., Yokota, T., Wennberg, P. O., Toon, G. C., Wunch, D., Roehl, C. M., Notholt, J., Warneke, T., Messerschmidt, J., Griffith, D. W. T., Deutscher, N. M., Sherlock, V., Connor, B., Robinson, J., Sussmann, R., and Rettinger, M.: Preliminary validation of column-averaged vol- ume mixing ratios of carbon dioxide and methane retrieved from GOSAT short-wavelength infrared spectra, Atmos. Meas. Tech., 4, 1061-1076, https://doi.org/10.5194/amt-4-1061-2011, 2011. · DOI
  25. Nassar, R., Hill, T. G., McLinden, C. A., Wunch, D., Jones, D. B. A., and Crisp, D.: Quantifying CO 2 Emissions From Individ- ual Power Plants From Space, Geophys. Res. Lett., 44, 10045- 10053, https://doi.org/10.1002/2017GL074702, 2017. · DOI
  26. Olsen, S. C. and Randerson, J. T.: Differences between sur- face and column atmospheric CO 2 and implications for car- bon cycle research, J. Geophys. Res.-Atmos., 109, D02301, https://doi.org/10.1029/2003JD003968, 2004. · DOI
  27. Ostler, A., Sussmann, R., Rettinger, M., Deutscher, N. M., Dohe, S., Hase, F., Jones, N., Palm, M., and Sinnhuber, B.-M.: Multistation intercomparison of column-averaged methane from NDACC and TCCON: impact of dynamical variability, Atmos. Meas. Tech., 7, 4081-4101, https://doi.org/10.5194/amt-7-4081-2014, 2014. · DOI
  28. Petri, C., Warneke, T., Jones, N., Ridder, T., Messerschmidt, J., Weinzierl, T., Geibel, M., and Notholt, J.: Remote sensing of CO 2 and CH 4 using solar absorption spectrometry with a low resolution spectrometer, Atmos. Meas. Tech., 5, 1627-1635, https://doi.org/10.5194/amt-5-1627-2012, 2012. · DOI
  29. Schneider, M. and Hase, F.: Ground-based FTIR water vapour profile analyses, Atmos. Meas. Tech., 2, 609-619, https://doi.org/10.5194/amt-2-609-2009, 2009. · DOI
  30. Sepúlveda, E., Schneider, M., Hase, F., García, O. E., Gomez- Pelaez, A., Dohe, S., Blumenstock, T., and Guerra, J. C.: Long- term validation of tropospheric column-averaged CH 4 mole frac- tions obtained by mid-infrared ground-based FTIR spectrometry, Atmos. Meas. Tech., 5, 1425-1441, https://doi.org/10.5194/amt- 5-1425-2012, 2012. · DOI
  31. Tallis, L., Coleman, M., Gardiner, T., Ptashnik, I., and Shine, K.: Assessment of the consistency of H 2 O line intensities over the near-infrared using sun-pointing ground-based Fourier trans- form spectroscopy, J. Quant. Spectrosc. Ra., 112, 2268-2280, https://doi.org/10.1016/j.jqsrt.2011.06.007, 2011. · DOI
  32. Washenfelder, R. A., Toon, G. C., Blavier, J.-F., Yang, Z., Allen, N. T., Wennberg, P. O., Vay, S. A., Matross, D. M., and Daube, B. C.: Carbon dioxide column abundances at the Wis- consin Tall Tower site, J. Geophys. Res.-Atmos., 111, D22305, https://doi.org/10.1029/2006JD007154, 2006. · DOI
  33. Wunch, D., Toon, G. C., Wennberg, P. O., Wofsy, S. C., Stephens, B. B., Fischer, M. L., Uchino, O., Abshire, J. B., Bernath, P., Biraud, S. C., Blavier, J.-F. L., Boone, C., Bowman, K. P., Brow- ell, E. V., Campos, T., Connor, B. J., Daube, B. C., Deutscher, N. M., Diao, M., Elkins, J. W., Gerbig, C., Gottlieb, E., Grif- fith, D. W. T., Hurst, D. F., Jiménez, R., Keppel-Aleks, G., Kort, E. A., Macatangay, R., Machida, T., Matsueda, H., Moore, F., Morino, I., Park, S., Robinson, J., Roehl, C. M., Sawa, Y., Sher- lock, V., Sweeney, C., Tanaka, T., and Zondlo, M. A.: Cali- bration of the Total Carbon Column Observing Network us- ing aircraft profile data, Atmos. Meas. Tech., 3, 1351-1362, https://doi.org/10.5194/amt-3-1351-2010, 2010. · DOI
  34. Wunch, D., Toon, G. C., Blavier, J.-F. L., Washenfelder, R. A., Notholt, J., Connor, B. J., Griffith, D. W. T., Sher- lock, V., and Wennberg, P.: The Total Carbon Column Ob- serving Network, Philos. Trans. Ser. A, 369, 2087-2112, https://doi.org/10.1098/rsta.2010.0240, 2011. · DOI
  35. Wunch, D., Toon, G. C., Sherlock, V., Deutscher, N. M., Liu, X., Feist, D. G., and Wennberg, P. O.: The Total Carbon Column Observing Network's GGG2014 Data Version, 10.14291/TC- CON.GGG2014.DOCUMENTATION.R0, 2015. · DOI
  36. Wunch, D., Wennberg, P. O., Osterman, G., Fisher, B., Naylor, B., Roehl, C. M., O'Dell, C., Mandrake, L., Viatte, C., Kiel, M., Griffith, D. W. T., Deutscher, N. M., Velazco, V. A., Notholt, J., Warneke, T., Petri, C., De Maziere, M., Sha, M. K., Sussmann, R., Rettinger, M., Pollard, D., Robinson, J., Morino, I., Uchino, O., Hase, F., Blumenstock, T., Feist, D. G., Arnold, S. G., Strong, K., Mendonca, J., Kivi, R., Heikkinen, P., Iraci, L., Podolske, J., Hillyard, P. W., Kawakami, S., Dubey, M. K., Parker, H. A., Sepulveda, E., García, O. E., Te, Y., Jeseck, P., Gunson, M. R., Crisp, D., and Eldering, A.: Comparisons of the Orbiting Carbon Observatory-2 (OCO-2) X CO 2 measurements with TCCON, At- mos. Meas. Tech., 10, 2209-2238, https://doi.org/10.5194/amt- 10-2209-2017, 2017. · DOI
  37. Ye, X., Lauvaux, T., Kort, E. A., Oda, T., Feng, S., Lin, J. C., Yang, E., and Wu, D.: Constraining fossil fuel CO 2 emissions from urban area using OCO-2 observations of total column CO 2 , Atmos. Chem. Phys. Discuss., https://doi.org/10.5194/acp-2017- 1022, 2017. · DOI

Cited by

Sorted by citations

Authors
Frey, M., Sha, M. K., Hase, F., Kiel, M., Blumenstock, T., Harig, R., Surawicz, G., Deutscher, N. M., Shiomi, K., Franklin, J. E., Bösch, H., Chen, J., Grutter, M., Ohyama, H., Sun, Y., Butz, A., Mengistu Tsidu, G., Ene, D., Wunch, D., Cao, Z., Garcia, O., Ramonet, M., Vogel, F., & Orphal, J.
Affiliations
  • Karlsruhe Institute of Technology (DE)
  • Bruker (Germany) (DE)
  • University of Wollongong (AU)
  • Japan Aerospace Exploration Agency (JP)
  • Harvard University (US)
  • Technical University of Munich (DE)
  • Universidad Nacional Autónoma de México (MX)
  • National Institute for Environmental Studies (JP)
  • Chinese Academy of Sciences (CN)
  • Heidelberg University (DE)
  • University of Toronto (CA)
  • Laboratoire des Sciences du Climat et de l'Environnement (FR)
  • Environment and Climate Change Canada (CA)
Corresponding author
Frey, Matthias
Venue
Atmospheric Measurement Techniques
Published
2019-03-11
Volume
12
Issue
3
Pages
1513-1530
ISSN
  • 1867-1381 (ISSN-L)
  • 1867-8548
OpenAlex
W2805504023
Cited by
238
References
1
Citations by year
2026: 18 · 2025: 35 · 2024: 38 · 2023: 27 · 2022: 54 · 2021: 47 · 2020: 13 · 2019: 6
FWCI
15.44
Type
journal article
Language
en
Open access
Locations
  • Atmospheric measurement techniques (publishedVersion, cc-by)
  • HAL (submittedVersion, other-oa)
  • Arcimis (State Meteorological Agency) (submittedVersion, cc-by-nc-nd)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion, cc-by)
  • Research Online (University of Wollongong) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
  • Figshare (submittedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion, cc-by)
  • mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, other-oa)
Funders
  • National Aeronautics and Space Administration
  • Agence Nationale de la Recherche (ANR-17-CE04-0013)
  • University of Wollongong
  • Australian Research Council (DE140100178)
Topics
  • Physical Sciences › Environmental Science › Global and Planetary Change › Atmospheric and Environmental Gas Dynamics
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Engineering › Aerospace Engineering › Calibration and Measurement Techniques
Keywords
COCCON, TCCON, Fourier transform infrared spectrometer, XCO2, XCH4, instrument stability, long-term drift

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review