S5P TROPOMI NO 2 slant column retrieval: method, stability, uncertainties and comparisons with OMI
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The Tropospheric Monitoring Instrument (TROPOMI), aboard the Sentinel-5 Precursor (S5P) satellite, launched on 13 October 2017, provides measurements of atmospheric trace gases and of cloud and aerosol properties at an unprecedented spatial resolution of approximately 7×3.5 km2 (approx. 5.5×3.5 km2 as of 6 August 2019), achieving near-global coverage in 1 d. The retrieval of nitrogen dioxide (NO2) concentrations is a three-step procedure: slant column density (SCD) retrieval, separation of the SCD in its stratospheric and tropospheric components, and conversion of these into vertical column densities. This study focusses on the TROPOMI NO2 SCD retrieval: the retrieval method used, the stability of the SCDs and the SCD uncertainties, and a comparison with the Ozone Monitoring Instrument (OMI) NO2 SCDs. The statistical uncertainty, based on the spatial variability of the SCDs over a remote Pacific Ocean sector, is 8.63 µmol m−2 for all pixels (9.45 µmol m−2 for clear-sky pixels), which is very stable over time and some 30 % less than the long-term average over OMI–QA4ECV data (since the pixel size reduction TROPOMI uncertainties are ∼8 % larger). The SCD uncertainty reported by the differential optical absorption spectroscopy (DOAS) fit is about 10 % larger than the statistical uncertainty, while for OMI–QA4ECV the DOAS uncertainty is some 20 % larger than its statistical uncertainty. Comparison of the SCDs themselves over the Pacific Ocean, averaged over 1 month, shows that TROPOMI is about 5 % higher than OMI–QA4ECV, which seems to be due mainly to the use of the so-called intensity offset correction in OMI–QA4ECV but not in TROPOMI: turning that correction off means about 5 % higher SCDs. The row-to-row variation in the SCDs of TROPOMI, the “stripe amplitude”, is 2.15 µmol m−2, while for OMI–QA4ECV it is a factor of ∼2 (∼5) larger in 2005 (2018); still, a so-called stripe correction of this non-physical across-track variation is useful for TROPOMI data. In short, TROPOMI shows a superior performance compared with OMI–QA4ECV and operates as anticipated from instrument specifications. The TROPOMI data used in this study cover 30 April 2018 up to 31 January 2020.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
The HITRAN2012 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Babikov, Y., Barbe, A., Chris Benner, D., Bernath, P. F., Birk, M., Bizzocchi, L., Boudon, V., Brown, L. R., et al. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2013.07.002 · Cited by 3,255
Inverse Methods for Atmospheric Sounding: Theory and Practice
Rodgers, C. D. (2000) · Series on Atmospheric, Oceanic and Planetary Physics · doi:10.1142/3171 · Cited by 3,057
Veefkind, J. P., Aben, I., McMullan, K., Förster, H., de Vries, J., Otter, G., Claas, J., Eskes, H. J., de Haan, J. F., Kleipool, Q., et al. (2012) · Remote Sensing of Environment · doi:10.1016/j.rse.2011.09.027 · Cited by 2,648
Self-citationAbsorption spectrum (380–700 nm) of pure water II Integrating cavity measurements
Pope, R. M., & Fry, E. S. (1997) · Applied Optics · doi:10.1364/ao.36.008710 · Cited by 2,297
The ozone monitoring instrument
Levelt, P. F., van den Oord, G. H. J., Dobber, M. R., Malkki, A., Visser, H., de Vries, J., Stammes, P., Lundell, J. O. V., & Saari, H. (2006) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2006.872333 · Cited by 2,007
SCIAMACHY: Mission Objectives and Measurement Modes
Bovensmann, H., Burrows, J. P., Buchwitz, M., Frerick, J., Noël, S., Rozanov, V. V., Chance, K. V., & Goede, A. P. H. (1999) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1999)056<0127:smoamm>2.0.co;2 · Cited by 1,984
The influence of nitrogen oxides on the atmospheric ozone content
Crutzen, P. J. (1970) · Quarterly Journal of the Royal Meteorological Society · doi:10.1002/qj.49709640815 · Cited by 1,594
The Global Ozone Monitoring Experiment (GOME): Mission Concept and First Scientific Results
Burrows, J. P., Weber, M., Buchwitz, M., Rozanov, V., Ladstätter-Weißenmayer, A., Richter, A., DeBeek, R., Hoogen, R., Bramstedt, K., Eichmann, K.-U., et al. (1999) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1999)056<0151:tgomeg>2.0.co;2 · Cited by 1,371
Improved Attribution of Climate Forcing to Emissions
Shindell, D. T., Faluvegi, G., Koch, D. M., Schmidt, G. A., Unger, N., & Bauer, S. E. (2009) · Science · doi:10.1126/science.1174760 · Cited by 868
Cited by
Near-real-time monitoring of global CO2 emissions reveals the effects of the COVID-19 pandemic
Liu, Z., Ciais, P., Deng, Z., Lei, R., Davis, S. J., Feng, S., Zheng, B., Cui, D., Dou, X., Zhu, B., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18922-7 · Cited by 795
Wei, J., Liu, S., Li, Z., Liu, C., Qin, K., Liu, X., Pinker, R. T., Dickerson, R. R., Lin, J., Boersma, K. F., et al. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.2c03834 · Cited by 361
Self-citationAbrupt decline in tropospheric nitrogen dioxide over China after the outbreak of COVID-19
Liu, F., Page, A., Strode, S. A., Yoshida, Y., Choi, S., Zheng, B., Lamsal, L. N., Li, C., Krotkov, N. A., Eskes, H., et al. (2020) · Science Advances · doi:10.1126/sciadv.abc2992 · Cited by 348
Self-citationGlobal fine-scale changes in ambient NO2 during COVID-19 lockdowns
Cooper, M. J., Martin, R. V., Hammer, M. S., Levelt, P. F., Veefkind, P., Lamsal, L. N., Krotkov, N. A., Brook, J. R., & McLinden, C. A. (2022) · Nature · doi:10.1038/s41586-021-04229-0 · Cited by 300
Disentangling the Impact of the COVID‐19 Lockdowns on Urban NO 2 From Natural Variability
Goldberg, D. L., Anenberg, S. C., Griffin, D., McLinden, C. A., Lu, Z., & Streets, D. G. (2020) · Geophysical Research Letters · doi:10.1029/2020gl089269 · Cited by 289
NOx Emission Reduction and Recovery during COVID-19 in East China
Zhang, R., Zhang, Y., Lin, H., Feng, X., Fu, T.-M., & Wang, Y. (2020) · Atmosphere · doi:10.3390/atmos11040433 · Cited by 233
“The Royal Dutch Meteorological Institute (KNMI) TM5-MP-DOMINO NO2 retrieval algorithm employs the differential optical absorption spectroscopy (DOAS) to derive NO2 slant column densities (SCDs) using visible wavelengths between 400 and 496 nm [22,24].”
MethodJudd, L. M., Al-Saadi, J. A., Szykman, J. J., Valin, L. C., Janz, S. J., Kowalewski, M. G., Eskes, H. J., Veefkind, J. P., Cede, A., Mueller, M., et al. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6113-2020 · Cited by 229
Self-citationMiyazaki, K., Bowman, K., Sekiya, T., Takigawa, M., Neu, J. L., Sudo, K., Osterman, G., & Eskes, H. (2021) · Science Advances · doi:10.1126/sciadv.abf7460 · Cited by 201
Self-citationNOx Emissions Reduction and Rebound in China Due to the COVID‐19 Crisis
Ding, J., van der A, R. J., Eskes, H. J., Mijling, B., Stavrakou, T., van Geffen, J. H. G. M., & Veefkind, J. P. (2020) · Geophysical Research Letters · doi:10.1029/2020gl089912 · Cited by 200
“Despite the much smaller footprints, the spectral fits of the individual TROPOMI groud pixels have 30% smaller noise than those from the earlier Ozone Monitoring Instrument (OMI), and the average values agree well within 5% (van Geffen et al., 2020).”
BackgroundSelf-citationGoldberg, D. L., Anenberg, S. C., Kerr, G. H., Mohegh, A., Lu, Z., & Streets, D. G. (2021) · Earth's Future · doi:10.1029/2020ef001665 · Cited by 196
De Smedt, I., Pinardi, G., Vigouroux, C., Compernolle, S., Bais, A., Benavent, N., Boersma, F., Chan, K.-L., Donner, S., Eichmann, K.-U., et al. (2021) · Atmospheric Chemistry and Physics · doi:10.5194/acp-21-12561-2021 · Cited by 187
Rowe, J. P., Zarzana, K. J., Kille, N., Borsdorff, T., Goudar, M., Lee, C. F., Koenig, T. K., Romero-Alvarez, J., Campos, T., Knote, C., et al. (2022) · ACS Earth and Space Chemistry · doi:10.1021/acsearthspacechem.2c00048 · Cited by 25
Metadata
- Authors
- van Geffen, J., Boersma, K. F., Eskes, H., Sneep, M., ter Linden, M., Zara, M., & Veefkind, J. P.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2020-03-23
- Volume
- 13
- Issue
- 3
- Pages
- 1315-1335
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2995883393
- Cited by
- 446
- References
- 27
- FWCI
- 22.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.