Particle Loss Calculator – a new software tool for the assessment of the performance of aerosol inlet systems
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Most aerosol measurements require an inlet system to transport aerosols from a select sampling location to a suitable measurement device through some length of tubing. Such inlet systems must be optimized to minimize aerosol sampling artifacts and maximize sampling efficiency. In this study we introduce a new multifunctional software tool (Particle Loss Calculator, PLC) that can be used to quickly determine aerosol sampling efficiency and particle transport losses due to passage through arbitrary tubing systems. The software employs relevant empirical and theoretical relationships found in established literature and accounts for the most important sampling and transport effects that might be encountered during deployment of typical, ground-based ambient aerosol measurements through a constant-diameter sampling probe. The software treats non-isoaxial and non-isokinetic aerosol sampling, aerosol diffusion and sedimentation as well as turbulent inertial deposition and inertial deposition in bends and contractions of tubing. This software was validated through comparison with experimentally determined particle losses for several tubing systems bent to create various diffusion, sedimentation and inertial deposition properties. As long as the tube geometries are not "too extreme", agreement is satisfactory. We discuss the conclusions of these experiments, the limitations of the software and present three examples of the use of the Particle Loss Calculator in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holman, J. P. (1976) · Cited by 9,157
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731
Brunekreef, B., & Holgate, S. T. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11274-8 · Cited by 4,638
Fuchs, N. A., Daisley, R. E., Fuchs, M., & Davies, C. N. (1964) · Cited by 2,278
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
A review of atmospheric aerosol measurements
McMurry, P. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00455-0 · Cited by 832
Drewnick, F., Hings, S. S., DeCarlo, P., Jayne, J. T., Gonin, M., Fuhrer, K., Weimer, S., Jimenez, J. L., Demerjian, K. L., Borrmann, S., et al. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500182040 · Cited by 730
Self-citation(2001) · Cited by 666
Deposition of Suspended Particles from Turbulent Gas Streams
Friedlander, S. K., & Johnstone, H. F. (1957) · Industrial & Engineering Chemistry · doi:10.1021/ie50571a039 · Cited by 631
Gard, E., Mayer, J. E., Morrical, B. D., Dienes, T., Fergenson, D. P., & Prather, K. A. (1997) · Analytical Chemistry · doi:10.1021/ac970540n · Cited by 533
Slip Correction Measurements of Spherical Solid Aerosol Particles in an Improved Millikan Apparatus
Allen, M. D., & Raabe, O. G. (1985) · Aerosol Science and Technology · doi:10.1080/02786828508959055 · Cited by 504
A Particle-into-Liquid Collector for Rapid Measurement of Aerosol Bulk Chemical Composition
Weber, R. J., Orsini, D., Daun, Y., Lee, Y.-N., Klotz, P. J., & Brechtel, F. (2001) · Aerosol Science and Technology · doi:10.1080/02786820152546761 · Cited by 425
Particle deposition in turbulent duct flows—comparisons of different model predictions
Tian, L., & Ahmadi, G. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2006.12.003 · Cited by 399
Orsini, D. A., Ma, Y., Sullivan, A., Sierau, B., Baumann, K., & Weber, R. J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)01015-4 · Cited by 389
Techniques for collection of representative aerosol samples
Belyaev, S. P., & Levin, L. M. (1974) · Journal of Aerosol Science · doi:10.1016/0021-8502(74)90130-x · Cited by 238
Aerosol Sampling: Science and Practice
Vincent, J. H. (1989) · Medical Entomology and Zoology · Cited by 220
Bukowiecki, N., Dommen, J., Prévôt, A. S. H., Richter, R., Weingartner, E., & Baltensperger, U. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00694-5 · Cited by 207
Kolb, C. E., Herndon, S. C., McManus, J. B., Shorter, J. H., Zahniser, M. S., Nelson, D. D., Jayne, J. T., Canagaratna, M. R., & Worsnop, D. R. (2004) · Environmental Science & Technology · doi:10.1021/es030718p · Cited by 193
Diesel Aerosol Sampling in the Atmosphere
Kittelson, D., Johnson, J., Watts, W., Wei, Q., Drayton, M., Paulsen, D., & Bukowiecki, N. (2000) · SAE Technical Paper Series · doi:10.4271/2000-01-2212 · Cited by 176
“Sniffer”—a novel tool for chasing vehicles and measuring traffic pollutants
Pirjola, L., Parviainen, H., Hussein, T., Valli, A., Hämeri, K., Aaalto, P., Virtanen, A., Keskinen, J., Pakkanen, T. A., Mäkelä, T., et al. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.047 · Cited by 164
Kumar, P., Fennell, P. S., Symonds, J. P. R., & Britter, R. E. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.003 · Cited by 98
Cited by
Recent progress in understanding physical and chemical properties of African and Asian mineral dust
Formenti, P., Schütz, L., Balkanski, Y., Desboeufs, K., Ebert, M., Kandler, K., Petzold, A., Scheuvens, D., Weinbruch, S., & Zhang, D. (2011) · Atmospheric Chemistry and Physics · doi:10.5194/acp-11-8231-2011 · Cited by 447
Biofuel blending reduces particle emissions from aircraft engines at cruise conditions
Moore, R. H., Thornhill, K. L., Weinzierl, B., Sauer, D., D’Ascoli, E., Kim, J., Lichtenstern, M., Scheibe, M., Beaton, B., Beyersdorf, A. J., et al. (2017) · Nature · doi:10.1038/nature21420 · Cited by 414
Frequent new particle formation over the high Arctic pack ice by enhanced iodine emissions
Baccarini, A., Karlsson, L., Dommen, J., Duplessis, P., Vüllers, J., Brooks, I. M., Saiz-Lopez, A., Salter, M., Tjernström, M., Baltensperger, U., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18551-0 · Cited by 268
Di Biagio, C., Formenti, P., Balkanski, Y., Caponi, L., Cazaunau, M., Pangui, E., Journet, E., Nowak, S., Caquineau, S., Andreae, M. O., et al. (2017) · Atmospheric Chemistry and Physics · doi:10.5194/acp-17-1901-2017 · Cited by 194
“In order to compare and combine extractive measurements (size distribution, filter sampling, and SW optics), particle losses due to aspiration and transmission in the sampling lines were calculated using the particle loss calculator (PLC) software (von der Weiden et al., 2009).”
MethodTimko, M. T., Herndon, S. C., de la Rosa Blanco, E., Wood, E. C., Yu, Z., Miake-Lye, R. C., Knighton, W. B., Shafer, L., DeWitt, M. J., & Corporan, E. (2011) · Combustion Science and Technology · doi:10.1080/00102202.2011.581717 · Cited by 69
“More details on estimating particle losses during transport through sampling tubes are available in the literature (Kumar et al, 2008 ; von der Weiden et al, 2009 ).”
BackgroundMethod
Metadata
- Authors
- von der Weiden, S.-L., Drewnick, F., & Borrmann, S.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2009-09-03
- Volume
- 2
- Issue
- 2
- Pages
- 479-494
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2166715881
- Cited by
- 423
- References
- 21
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.