Recognizing Hand and Finger Gestures with IMU based Motion and EMG based Muscle Activity Sensing
Open accessThe DOI matches its Crossref record.
Abstract
Session- and person-independent recognition of hand and finger gestures is of utmost importance for the practicality of gesture based interfaces. In this paper we evaluate the performance of a wearable gesture recognition system that captures arm, hand, and finger motions by measuring movements of, and muscle activity at the forearm. We fuse the signals of an Inertial Measurement Unit (IMU) worn at the wrist, and the Electromyogram (EMG) of muscles in the forearm to infer hand and finger movements. A set of 12 gestures was defined, motivated by their similarity to actual physical manipulations and to gestures known from the interaction with mobile devices. We recorded performances of our gesture set by five subjects in multiple sessions. The resulting datacorpus will be made publicly available to build a common ground for future evaluations and benchmarks. Hidden Markov Models (HMMs) are used as classifiers to discriminate between the defined gesture classes. We achieve a recognition rate of 97.8 % in session-independent, and of 74.3 % in person-independent recognition. Additionally, we give a detailed analysis of error characteristics and of the influence of each modality to the results to underline the benefits of using both modalities together. 1
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
A Wearable Hand Rehabilitation System With Soft Gloves
Chen, X., Gong, L., Wei, L., Yeh, S.-C., Da Xu, L., Zheng, L., & Zou, Z. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3010369 · Cited by 194
Exploration of Force Myography and surface Electromyography in hand gesture classification
Jiang, X., Merhi, L.-K., Xiao, Z. G., & Menon, C. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.015 · Cited by 172
Metadata
- Authors
- Georgi, M., Amma, C., & Schultz, T.
- Venue
- Proceedings of the International Conference on Bio-inspired Systems and Signal Processing
- Published
- 2015
- Pages
- 99-108
- OpenAlex
- W2086184552
- Cited by
- 134
- References
- 0
- FWCI
- 9.37
- Type
- conference paper
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recognizing Hand and Finger Gestures with IMU based Motion and EMG based Muscle Activity Sensing. https://app.cochat.ai/papers/10.5220/0005276900990108
- The paper
- Georgi, M., Amma, C., & Schultz, T. (2015). Recognizing Hand and Finger Gestures with IMU based Motion and EMG based Muscle Activity Sensing. Proceedings of the International Conference on Bio-inspired Systems and Signal Processing. https://doi.org/10.5220/0005276900990108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.