A Wearable Hand Rehabilitation System With Soft Gloves
Abstract
Hand paralysis is one of the most common complications in stroke patients, which severely impacts their daily lives. This article presents a wearable hand rehabilitation system that supports both mirror therapy and task-oriented therapy. A pair of gloves, i.e., a sensory glove and a motor glove, was designed and fabricated with a soft, flexible material, providing greater comfort and safety than conventional rigid rehabilitation devices. The sensory glove worn on the nonaffected hand, which contains the force and flex sensors, is used to measure the gripping force and bending angle of each finger joint for motion detection. The motor glove, driven by micromotors, provides the affected hand with assisted driving force to perform training tasks. Machine learning is employed to recognize the gestures from the sensory glove and to facilitate the rehabilitation tasks for the affected hand. The proposed system offers 16 kinds of finger gestures with an accuracy of 93.32%, allowing patients to conduct mirror therapy using fine-grained gestures for training a single finger and multiple fingers in coordination. A more sophisticated task-oriented rehabilitation with mirror therapy is also presented, which offers six types of training tasks with an average accuracy of 89.4% in real time.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This combination therapy can achieve independent rehabilitation without a guide.[158]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [158]
Citations
Cites
Wolf, S. L., Winstein, C. J., Miller, J. P., Taub, E., Uswatte, G., Morris, D., Giuliani, C., Light, K. E., Nichols-Larsen, D., & EXCITE Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.17.2095 · Cited by 1,889 · cited 1×
“3010369 Hemiparesis, the loss of ipsilateral motor function, is one of the most common after effects of a stroke [2], [3].”
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617 · cited 1×
“There are various kinds of actuation mechanism developed for exoskeleton robotic glove, such as pneumatic actuators [18], elastomeric actuators [36], rigid linkage [8], and tendons [10].”
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 1×
“Feature selection is used to improve the accuracy [46].”
Learning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162 · cited 1×
“[35] implemented a scalable tactile”
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992 · cited 1×
“The main limitation for sEMG is its low spatial resolution caused by muscle crosstalk [27] and fatigue [28].”
Rehabilitation of hemiparesis after stroke with a mirror
Altschuler, E. L., Wisdom, S. B., Stone, L., Foster, C., Galasko, D., Llewellyn, D. M. E., & Ramachandran, V. (1999) · The Lancet · doi:10.1016/s0140-6736(99)00920-4 · Cited by 642 · cited 2×
“[2] conducted a rehabilitation experiment on poststroke patients with hemiparesis by placing a vertical, parasagittal mirror between the nonaffected (healthy”
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473 · cited 1×
“[17], and Yi et al.”
Design of a haptic arm exoskeleton for training and rehabilitation
Gupta, A., & O'Malley, M. K. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.875558 · Cited by 328
Feasibility of Wrist-Worn, Real-Time Hand, and Surface Gesture Recognition via sEMG and IMU Sensing
Jiang, S., Lv, B., Guo, W., Zhang, C., Wang, H., Sheng, X., & Shull, P. B. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2779814 · Cited by 239 · cited 2×
“neighbor (kNN) [40], dynamic time wrapping (DTW) [26], linear discriminant analysis (LDA) [41], supported vector ma-”
An EMG-Based Robot Control Scheme Robust to Time-Varying EMG Signal Features
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040832 · Cited by 224 · cited 1×
“The main limitation for sEMG is its low spatial resolution caused by muscle crosstalk [27] and fatigue [28].”
Cited by
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Wang, H., Ding, Q., Luo, Y., Wu, Z., Yu, J., Chen, H., Zhou, Y., Zhang, H., Tao, K., Chen, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202309868 · Cited by 290
Self-citationSoft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
Smart Tactile Gloves for Haptic Interaction, Communication, and Rehabilitation
Ozioko, O., & Dahiya, R. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100091 · Cited by 233
Metadata
- Authors
- Chen, X., Gong, L., Wei, L., Yeh, S.-C., Da Xu, L., Zheng, L., & Zou, Z.
- Affiliations
- Fudan University (CN)
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2021-02
- Volume
- 17
- Issue
- 2
- Pages
- 943-952
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W3045185600
- Semantic Scholar
- 1674270d97d592318f9260da6f7db44c32f8017a
- Cited by
- 194
- References
- 48
- Citations by year
- 2026: 22 · 2025: 35 · 2024: 43 · 2023: 45 · 2022: 29 · 2021: 19
- FWCI
- 13.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Informatics (publishedVersion)
- Funders
- National Natural Science Foundation of China (61876039)
- Shanghai Municipal Science and Technology (2018SHZDZX01)
- Shanghai Platform for Neuromorphic and AI Chip (17DZ2260900)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- hand rehabilitation, stroke, wearable glove, soft robotics, mirror therapy, task-oriented therapy, gesture recognition, force sensor, flex sensors, upper limb paralysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wearable Hand Rehabilitation System With Soft Gloves. https://app.cochat.ai/papers/10.1109/tii.2020.3010369
- The paper
- Chen, X., Gong, L., Wei, L., Yeh, S.-C., Da Xu, L., Zheng, L., & Zou, Z. (2021). A Wearable Hand Rehabilitation System With Soft Gloves. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2020.3010369
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.