The DOI matches its Crossref record.
American Journal of Roentgenology
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The linear-quadratic formula and progress in fractionated radiotherapy
Fowler, J. F. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-740-679 · Cited by 2,252
Examining the technology acceptance model using physician acceptance of telemedicine technology
Hu, P. J., Chau, P. Y. K., Sheng, O. R. L., & Tam, K. Y. (1999) · Journal of Management Information Systems · doi:10.1080/07421222.1999.11518247 · Cited by 1,951
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Aloe Vera: A Valuable Ingredient for the Food, Pharmaceutical and Cosmetic Industries—A Review
ESHUN, K., & HE, Q. (2004) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408690490424694 · Cited by 699
Witmer, L. M. (1997) · Journal of Vertebrate Paleontology · doi:10.1080/02724634.1997.10011027 · Cited by 544
Metadata
- Authors
- Bell, D., Campos, A., & Deng, F.
- Venue
- Radiopaedia.org
- Publisher
- Radiopaedia.org
- Published
- 2017-10-30
- OpenAlex
- W4252448956
- Cited by
- 806
- References
- 0
- Type
- reference entry
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: American Journal of Roentgenology. https://app.cochat.ai/papers/10.53347/rid-56407
- The paper
- Bell, D., Campos, A., & Deng, F. (2017). American Journal of Roentgenology. Radiopaedia.org. https://doi.org/10.53347/rid-56407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.