Fluorescence Rejection by Shifted Excitation Raman Difference Spectroscopy at Multiple Wavelengths for the Investigation of Biological Samples
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Shifted excitation Raman difference spectroscopy (SERDS) was applied for an effective fluorescence removal in the Raman spectra of meat, fat, connective tissue, and bone from pork and beef. As excitation light sources, microsystem diode lasers emitting at 783 nm, 671 nm, and 488 nm each incorporating two slightly shifted excitation wavelengths with a spectral difference of about 10 cm−1 necessary for SERDS operation were used. The moderate fluorescence interference for 783 nm excitation as well as the increased background level at 671 nm was efficiently rejected using SERDS resulting in a straight horizontal baseline. This allows for identification of all characteristic Raman signals including weak bands which are clearly visible and overlapping signals that are resolved in the SERDS spectra. At 488 nm excitation, the spectra contain an overwhelming fluorescence interference masking nearly all Raman signals of the probed tissue samples. However, the essentially background-free SERDS spectra enable determining the majority of characteristic Raman bands of the samples under investigation. Furthermore, 488 nm excitation reveals prominent carotenoid signals enhanced due to resonance Raman scattering which are present in the beef samples but absent in pork tissue enabling a rapid meat species differentiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term stability of a Raman instrument determining iodine value in pork adipose tissue
Olsen, E. F., Baustad, C., Egelandsdal, B., Rukke, E.-O., & Isaksson, T. (2010) · Meat Science · doi:10.1016/j.meatsci.2009.12.008 · Cited by 21 · cited 1×
“Vibrational assignment 783 nm excitation 671 nm excitation 488 nm excitation Literature value [References] Quartz 492 494 490 Quartz 605 606 607 =C–H in-plane deformation 726 723 — 727 [23] C–C stretch, CH3 rock, C–O stretch 842 843 843 800–920 [24] C–C stretch, CH3 rock, C–O stretch 868 869 872 800–920 [24] C–C stret…”
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Time-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Korinth, F., Schmälzlin, E., Stiebing, C., Urrutia, T., Micheva, G., Sandin, C., Müller, A., Maiwald, M., Sumpf, B., Krafft, C., et al. (2020) · Sensors · doi:10.3390/s20236723 · Cited by 13
Metadata
- Authors
- Sowoidnich, K., & Kronfeldt, H.-D.
- Venue
- ISRN Spectroscopy
- Publisher
- Wiley
- Published
- 2012-08-08
- Volume
- 2012
- Pages
- 1-11
- ISSN
- 2090-8776 (ISSN-L)
- OpenAlex
- W2148978326
- Cited by
- 39
- References
- 1
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Rejection by Shifted Excitation Raman Difference Spectroscopy at Multiple Wavelengths for the Investigation of Biological Samples. https://app.cochat.ai/papers/10.5402/2012/256326
- The paper
- Sowoidnich, K., & Kronfeldt, H.-D. (2012). Fluorescence Rejection by Shifted Excitation Raman Difference Spectroscopy at Multiple Wavelengths for the Investigation of Biological Samples. ISRN Spectroscopy. https://doi.org/10.5402/2012/256326
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.