The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Bioabsorbable Implants in Orthopaedics: New Developments and Clinical Applications
Abstract
The use of bioabsorbable implants in orthopaedic surgical procedures is becoming more frequent. Advances in polymer science have allowed the production of implants with the mechanical strength necessary for such procedures. Bioabsorbable materials have been utilized for the fixation of fractures as well as for soft-tissue fixation. These implants offer the advantages of gradual load transfer to the healing tissue, reduced need for hardware removal, and radiolucency, which facilitates postoperative radiographic evaluation. Reported complications with the use of these materials include sterile sinus tract formation, osteolysis, synovitis, and hypertrophic fibrous encapsulation. Further study is required to determine the clinical situations in which these materials are of most benefit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Orthopaedic applications for PLA‐PGA biodegradable polymers
Athanasiou, K., Agrawal, C., Barber, F., & Burkhart, S. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70099-4 · Cited by 487
Cited by
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Zhao, D., Witte, F., Lu, F., Wang, J., Li, J., & Qin, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.017 · Cited by 945
Castellani, C., Lindtner, R. A., Hausbrandt, P., Tschegg, E., Stanzl-Tschegg, S. E., Zanoni, G., Beck, S., & Weinberg, A.-M. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.020 · Cited by 436
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr384 · Cited by 303
Biodegradable bone implants as a new hope to reduce device-associated infections-a systematic review
Paiva, J. C. C., Oliveira, L., Vaz, M. F., & Costa-de-Oliveira, S. (2022) · Bioengineering · doi:10.3390/bioengineering9080409 · Cited by 53
Metadata
- Authors
- Ciccone, W. J., Motz, C., Bentley, C., & Tasto, J. P.
- Venue
- Journal of the American Academy of Orthopaedic Surgeons
- Published
- 2001-09
- Volume
- 9
- Issue
- 5
- Pages
- 280-288
- ISSN
- 1067-151X (ISSN-L)
- OpenAlex
- W2159225309
- Cited by
- 195
- References
- 2
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioabsorbable Implants in Orthopaedics: New Developments and Clinical Applications. https://app.cochat.ai/papers/10.5435/00124635-200109000-00001
- The paper
- Ciccone, W. J., Motz, C., Bentley, C., & Tasto, J. P. (2001). Bioabsorbable Implants in Orthopaedics: New Developments and Clinical Applications. Journal of the American Academy of Orthopaedic Surgeons. https://doi.org/10.5435/00124635-200109000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.