Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 303

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade?

Serruys, P. W., Garcia-Garcia, H. M., Onuma, Y. · 2012 · European Heart Journal

Abstract

Drug-eluting bioresorbable scaffolds (BRSs) may in the near future change drastically the landscape of percutaneous coronary revascularization.1 In 1977, when Andreas Gruentzig introduced the concept of percutaneous transluminal coronary angioplasty, the most feared enemy of the operators was acute occlusion of the dilated lesion due to a combination of elastic recoil and intimal and medial dissection, sometimes aggravated by intraparietal haematoma (Figure 1).2 Surgical standby was a sine qua non condition for the safe performance of the percutaneous treatment. At short term, proliferative neointima and constrictive remodelling could dissipate the transient benefit of the therapeutic dilatation of the stenosis. However, in the case of favourable healing following the barotrauma, late lumen enlargement, plaque regression, and vessel remodelling could occur and be modulated by change in life style, preventive medicine, and pharmacological anti-atherosclerotic agents.3 ... In 1986, the introduction of metallic scaffolds was initially perceived as an ad hoc solution to the problem of acute vessel occlusion (Figure 1).4–6 But the implantation of the metallic endoluminal prosthesis in a thrombogenic milieu was considered as a double-edged sword. (‘The bailout stent. Is a friend in need always a friend indeed?’7) Nevertheless, scaffolding dissected post-balloon dilatation with a metallic mesh became an important safeguard in angioplasty. Furthermore, the recoil and constrictive remodelling appeared to be actively and efficiently counteracted, thereby reducing the frequency and the severity of the restenosis.8 However, the implantation of a permanent foreign body created and generated a new iatrogenic disease: intra-stent restenosis.9 The amount of neointima generated by the permanent implantation of a metallic scaffold was, as a matter of fact, larger than the one induced by the barotrauma of balloon angioplasty (loss following balloon angioplasty: 0.32 mm vs. loss following stent implantation: 0.65 mm).10,11

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehr384

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Cited by

See all 303

Metadata

Authors
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y.
Venue
European Heart Journal
Published
2011-10-31
Volume
33
Issue
1
Pages
16-25
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2086456362
Cited by
303
References
51
FWCI
18.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? https://app.cochat.ai/papers/10.1093/eurheartj/ehr384
The paper
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012). From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? European Heart Journal. https://doi.org/10.1093/eurheartj/ehr384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.