CoChat

Potential Usefulness of Noninvasive Autonomic Monitoring in Recognition of Arousals in Normal Healthy Children

O’Brien, Louise M., Gozal, David · 2007 · Journal of Clinical Sleep Medicine
Cited by 40

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

INTRODUCTION Current methods employed for scoring arousals in children may not be sensitive enough. Because arousals are associated with increases in sympathetic tone, measurement of sympathetic activity using noninvasive techniques could provide useful surrogate markers for arousals in children. METHODS Ten healthy children underwent overnight polysomnographic assessment with simultaneous pulse transit time (PTT) and peripheral arterial tonometry (PAT) measurements. Arousals (electroencephalogram and/or movement) and PTT and PAT events were identified independently, with scorers blinded to the other signals. RESULTS A total of 1985 events were identified in 10 records. Of these, 657 were electroencephalographic arousals, of which 548 (83%) were identified by either PTT and/or PAT. The sensitivity and specificity of PTT for recognizing arousals were 0.74 and 0.25, respectively, whereas the sensitivity and specificity of PAT for recognizing arousals were 0.57 and 0.13, respectively. Because movement arousals result in brief periods of artifact on the PTT and PAT signals, we reanalyzed the PTT and PAT events to include artifact events. Reanalysis increased the sensitivity of PTT for recognizing arousals to 0.96 and that of the PAT to 0.92 and increased PTT and PAT specificity to 0.30 and 0.19, respectively. CONCLUSION Both PTT and PAT events are extremely sensitive techniques for arousal recognition in children. Furthermore, a substantial proportion of autonomic events occur in children without any accompanying visually recognizable electroencephalographic changes, suggesting that PTT and PAT may provide useful alternatives for arousal recognition during ambulatory sleep monitoring in children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5664/jcsm.26744

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 40

Metadata

Authors
O’Brien, L. M., & Gozal, D.
Venue
Journal of Clinical Sleep Medicine
Published
2007-02-15
Volume
3
Issue
1
Pages
41-47
ISSN
  • 1550-9389 (ISSN-L)
  • 1550-9397
OpenAlex
W7123926577
Cited by
40
References
1
FWCI
3.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Potential Usefulness of Noninvasive Autonomic Monitoring in Recognition of Arousals in Normal Healthy Children. https://app.cochat.ai/papers/10.5664/jcsm.26744
The paper
O’Brien, L. M., & Gozal, D. (2007). Potential Usefulness of Noninvasive Autonomic Monitoring in Recognition of Arousals in Normal Healthy Children. Journal of Clinical Sleep Medicine. https://doi.org/10.5664/jcsm.26744

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.