CoChat

Evaluation of the Consensus Sleep Diary in a community sample: comparison with single-channel electroencephalography, actigraphy, and retrospective questionnaire

Open access
Dietch, Jessica R., Taylor, Daniel J. · 2021 · Journal of Clinical Sleep Medicine
Cited by 53

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The Consensus Sleep Diary (CSD) was developed by experts to promote standardization of sleep diary data across the field, but studies comparing the CSD with other assessments of sleep parameters are scarce. This study compared the CSD with 3 other methods to assess sleep duration, efficiency, and timing. Participants (n = 80) were community adults (mean age = 32.65 years, 63% female) who completed the time-stamped CSD and used single-channel electroencephalography (EEG) and actigraphy for 7 days at home, then completed a retrospective sleep questionnaire. Total sleep time (TST), sleep efficiency (SE), and sleep midpoint were compared using correlations, Bland-Altman plots, and limits of agreement (adjusted for repeated measures). Correlations between the CSD and all methods on TST were large (rs = .63–.75). Adjusted CSD average TST was 40 minutes greater than with EEG and 31 minutes greater than with actigraphy. Correlations between CSD, actigraphy, and EEG for SE were small (rs = .18), and there was a medium correlation with questionnaire (r = .42). Adjusted CSD average SE was 7% greater than EEG and 6% greater than actigraphy; both demonstrated heteroscedasticity. Sleep midpoint correlations between CSD and all methods were large (r = .92–.99). Adjusted CSD was, on average, 6 minutes later than EEG and 1 minute later than actigraphy. Questionnaire-derived sleep parameters demonstrated nonconstant bias; lesser values had positive bias and greater values had negative bias. The time-stamped CSD led to meaningful overestimations of TST and SE as measured by objective/inferred methods. However, sleep timing was rather accurately assessed with the CSD in comparison to objective/inferred measures. Researchers should carefully consider which sleep assessment methods are best aligned with their research question and parameters of interest, as methods do not demonstrate complete agreement. Dietch JR, Taylor DJ. Evaluation of the Consensus Sleep Diary in a community sample: comparison with single-channel electroencephalography, actigraphy, and retrospective questionnaire. J Clin Sleep Med. 2021;17(7):1389–1399.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5664/jcsm.9200

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Dietch, J. R., & Taylor, D. J.
Venue
Journal of Clinical Sleep Medicine
Published
2021-07
Volume
17
Issue
7
Pages
1389-1399
ISSN
  • 1550-9389 (ISSN-L)
  • 1550-9397
OpenAlex
W3133950729
Cited by
53
References
8
FWCI
9.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.