Interrater reliability of sleep stage scoring: a meta-analysis
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We evaluated the interrater reliabilities of manual polysomnography sleep stage scoring. We included all studies that employed Rechtschaffen and Kales rules or American Academy of Sleep Medicine standards. We sought the overall degree of agreement and those for each stage. The keywords were “Polysomnography (PSG),” “sleep staging,” “Rechtschaffen and Kales (R&K),” “American Academy of Sleep Medicine (AASM),” “interrater (interscorer) reliability,” and “Cohen’s kappa.” We searched PubMed, OVID Medline, EMBASE, the Cochrane library, KoreaMed, KISS, and the MedRIC. The exclusion criteria included automatic scoring and pediatric patients. We collected data on scorer histories, scoring rules, numbers of epochs scored, and the underlying diseases of the patients. A total of 101 publications were retrieved; 11 satisfied the selection criteria. The Cohen’s kappa for manual, overall sleep scoring was 0.76, indicating substantial agreement (95% confidence interval, 0.71–0.81; P < .001). By sleep stage, the figures were 0.70, 0.24, 0.57, 0.57, and 0.69 for the W, N1, N2, N3, and R stages, respectively. The interrater reliabilities for stage N2 and N3 sleep were moderate, and that for stage N1 sleep was only fair. We conducted a meta-analysis to generalize the variation in manual scoring of polysomnography and provide reference data for automatic sleep stage scoring systems. The reliability of manual scorers of polysomnography sleep stages was substantial. However, for certain stages, the results were poor; validity requires improvement. Lee YJ, Lee JY, Cho JH, Choi JH. Interrater reliability of sleep stage scoring: a meta-analysis. J Clin Sleep Med. 2022;18(1):193–202.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
The visual scoring of sleep in adults
Silber, M. H., Ancoli-Israel, S., Bonnet, M. H., Chokroverty, S., Grigg-Damberger, M. M., Hirshkowitz, M., Kapen, S., Keenan, S. A., Kryger, M. H., Penzel, T., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26814 · Cited by 1,064
The American Academy of Sleep Medicine Inter-scorer Reliability Program: Sleep Stage Scoring
Rosenberg, R. S., & Van Hout, S. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2350 · Cited by 456
The Visual Scoring of Sleep and Arousal in Infants and Children
Grigg-Damberger, M., Gozal, D., Marcus, C. L., Quan, S. F., Rosen, C. L., Chervin, R. D., Wise, M., Picchietti, D. L., Sheldon, S. H., & Iber, C. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26819 · Cited by 361 · cited 1×
“4,25 Because the scoring rules for infants and children are distinct from those for adults and have been applied separately, we decided to analyze studies including only adults.”
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
Automated sleep scoring: A review of the latest approaches
Fiorillo, L., Puiatti, A., Papandrea, M., Ratti, P.-L., Favaro, P., Roth, C., Bargiotas, P., Bassetti, C. L., & Faraci, F. D. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.07.007 · Cited by 284
Validation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216
Cited by
40 years of actigraphy in sleep medicine and current state of the art algorithms
Patterson, M. R., Nunes, A. A. S., Gerstel, D., Pilkar, R., Guthrie, T., Neishabouri, A., & Guo, C. C. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00802-1 · Cited by 91
Metadata
- Authors
- Lee, Y. J., Lee, J. Y., Cho, J. H., & Choi, J. H.
- Venue
- Journal of Clinical Sleep Medicine
- Published
- 2022-01
- Volume
- 18
- Issue
- 1
- Pages
- 193-202
- ISSN
- 1550-9389 (ISSN-L)
- 1550-9397
- OpenAlex
- W3186929955
- Cited by
- 174
- References
- 8
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interrater reliability of sleep stage scoring: a meta-analysis. https://app.cochat.ai/papers/10.5664/jcsm.9538
- The paper
- Lee, Y. J., Lee, J. Y., Cho, J. H., & Choi, J. H. (2022). Interrater reliability of sleep stage scoring: a meta-analysis. Journal of Clinical Sleep Medicine. https://doi.org/10.5664/jcsm.9538
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.