Agreement in Computer-Assisted Manual Scoring of Polysomnograms across Sleep Centers
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: To determine intersite agreement in respiratory event scoring of polysomnograms (PSGs) using different hypopnea definitions. DESIGN: Technical assessment. SETTING: Five academic medical centers. PARTICIPANTS: N/A. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Seventy good-quality PSGs performed in middle-aged women were manually scored by two experienced technologists at each of the five sleep centers using the particular laboratory's own software system. Studies were scored once by each scorer using American Academy of Sleep Medicine (AASM) standards for scoring sleep stages, arousals, and apneas. Hypopneas were then scored using three different AASM criteria: recommended, alternate, and research (Chicago). Means of each PSG variable for the scorers at each site were used to calculate an across-site intraclass correlation coefficient (ICC). Average AHI across the 10 scorers was 7.4 ± 12.3 (standard deviation) events/h using recommended criteria (ICC 0.984; 95% confidence interval [CI] 0.977-0.990), 12.1 ± 13.3 events/h using alternate criteria (ICC 0.947; 95% CI 0.889-0.972), and 15.1 ± 13.9 events/h with Chicago criteria (ICC 0.800; 95% CI 0.768-0.828). ICC across sites was 0.870 (95% CI = 0.847-0.889) for total sleep time, 0.861 (95% CI 0.837-0.881) for number of obstructive apneas and 0.683 (95% CI 0.640-0.722) for number of central apneas. ICCs across sites for hypopneas were very good using recommended criteria (ICC 0.843; 95% CI 0.820-0.870) but decreased when alternate criteria (ICC 0.728; 95% CI 0.689-0.763) and Chicago criteria (ICC 0.535; 95% CI 0.485-0.583) were used. CONCLUSION: Experienced scorers at different laboratories have very good agreement in hypopnea and AHI results when good-quality PSGs are scored using AASM-recommended criteria. Substantial degradation of reliability was observed for alternative definitions of hypopneas, particularly that proposed for research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The visual scoring of sleep in adults
Silber, M. H., Ancoli-Israel, S., Bonnet, M. H., Chokroverty, S., Grigg-Damberger, M. M., Hirshkowitz, M., Kapen, S., Keenan, S. A., Kryger, M. H., Penzel, T., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26814 · Cited by 1,064
The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index
Ruehland, W. R., Rochford, P. D., O’Donoghue, F. J., Pierce, R. J., Singh, P., & Thornton, A. T. (2009) · SLEEP · doi:10.1093/sleep/32.2.150 · Cited by 696
Obstructive Sleep Apnea Among Obese Patients With Type 2 Diabetes
Foster, G. D., Sanders, M. H., Millman, R., Zammit, G., Borradaile, K. E., Newman, A. B., Wadden, T. A., Kelley, D., Wing, R. R., Pi Sunyer, F. X., et al. (2009) · Diabetes Care · doi:10.2337/dc08-1776 · Cited by 600
Self-citationDANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
Noninferiority of Functional Outcome in Ambulatory Management of Obstructive Sleep Apnea
Kuna, S. T., Gurubhagavatula, I., Maislin, G., Hin, S., Hartwig, K. C., McCloskey, S., Hachadoorian, R., Hurley, S., Gupta, R., Staley, B., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1770oc · Cited by 228 · cited 1×
“7-9 Although centralized scoring decreases potential site-related differences, it is time consuming and requires funding of a separate core PSG laboratory with complicating issues related to transmission of files and sharing of private health information.”
BackgroundSelf-citationEffects of Varying Approaches for Identifying Respiratory Disturbances on Sleep Apnea Assessment
REDLINE, S., KAPUR, V. K., SANDERS, M. H., QUAN, S. F., GOTTLIEB, D. J., RAPOPORT, D. M., BONEKAT, W. H., SMITH, P. L., KILEY, J. P., & IBER, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9904031 · Cited by 225 · cited 1×
“5,6 As a result of these problems, sleep specialists in one sleep center may be uncertain how to interpret PSG reports generated by another sleep center.”
Background
Cited by
Benjafield, A. V., Ayas, N. T., Eastwood, P. R., Heinzer, R., Ip, M. S. M., Morrell, M. J., Nunez, C. M., Patel, S. R., Penzel, T., Pépin, J.-L., et al. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(19)30198-5 · Cited by 4,326
Self-citationNeural network analysis of sleep stages enables efficient diagnosis of narcolepsy
Stephansen, J. B., Olesen, A. N., Olsen, M., Ambati, A., Leary, E. B., Moore, H. E., Carrillo, O., Lin, L., Han, F., Yan, H., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07229-3 · Cited by 413
Self-citationArnal, P. J., Thorey, V., Debellemaniere, E., Ballard, M. E., Bou Hernandez, A., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., et al. (2020) · SLEEP · doi:10.1093/sleep/zsaa097 · Cited by 394
Obstructive sleep apnoea in the general population: highly prevalent but minimal symptoms
Arnardottir, E. S., Bjornsdottir, E., Olafsdottir, K. A., Benediktsdottir, B., & Gislason, T. (2016) · European Respiratory Journal · doi:10.1183/13993003.01148-2015 · Cited by 261
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
“Some studies suggest that the reproducibility of the findings from EEG may be modest compared to signals such as pulse oximetry which can be quantified objectively (Kuna et al 2013).”
BackgroundSelf-citationPerformance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
Malhotra, A., Younes, M., Kuna, S. T., Benca, R., Kushida, C. A., Walsh, J., Hanlon, A., Staley, B., Pack, A. I., & Pien, G. W. (2013) · Sleep · doi:10.5665/sleep.2548 · Cited by 222
Self-citationKuna, S. T., Shuttleworth, D., Chi, L., Schutte-Rodin, S., Friedman, E., Guo, H., Dhand, S., Yang, L., Zhu, J., Bellamy, S. L., et al. (2015) · Sleep · doi:10.5665/sleep.4898 · Cited by 97
Self-citationSleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Mansukhani, M. P., Kolla, B. P., Wang, Z., & Morgenthaler, T. I. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7750 · Cited by 51
“28 The classification of SDB as OSA or CSA did not appear to be affected by the hypopnea definition used.”
InfluentialThe Dreem Headband as an Alternative to Polysomnography for EEG Signal Acquisition and Sleep Staging
Arnal, P. J., Thorey, V., Ballard, M. E., Hernandez, A. B., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., Chennaoui, M., et al. (2019) · doi:10.1101/662734 · Cited by 20
Metadata
- Authors
- Kuna, S. T., Benca, R., Kushida, C. A., Walsh, J., Younes, M., Staley, B., Hanlon, A., Pack, A. I., Pien, G. W., & Malhotra, A.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-04-01
- Volume
- 36
- Issue
- 4
- Pages
- 583-589
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2075819626
- Cited by
- 95
- References
- 8
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.