CoChat

Overnight Polysomnography versus Respiratory Polygraphy in the Diagnosis of Pediatric Obstructive Sleep Apnea

Open access
Tan, Hui-Leng, Gozal, David, Ramirez, Helena Molero, Bandla, Hari P. R., Kheirandish-Gozal, Leila · 2014 · Sleep
Cited by 185

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Substantial discrepancies exist in the type of sleep studies performed to diagnose pediatric obstructive sleep apnea (OSA) in different countries. Respiratory polygraphic (RP) recordings are primarily performed in sleep laboratories in Europe, whereas polysomnography (PSG) constitutes the majority in the US and Australia. Home RP show consistent apnea-hypopnea index (AHI) underscoring, primarily because the total recording time is used as the denominator when calculating the AHI compared to total sleep time (TST). However, laboratory-based RP are less likely affected, since the presence of sleep technicians and video monitoring may enable more accurate TST estimates. We therefore examined differences in AHI in PSG and in-lab RP, and whether RP-based AHI may impact clinical decision making. METHODS: Of all the children assessed for possible OSA who underwent PSG evaluation, 100 were identified and divided into 4 groups: (A) those with AHI < 1/h TST (n = 20), (B) 1 ≤ AHI < 5/h TST (n = 40), (C) 5 ≤ AHI < 10/h TST (n = 20), and (D) AHI ≥ 10/h TST (n = 20). Electroencephalography, electrooculography, and electromyography channels were deleted from the original unscored recordings to transform them into RP, and then rescored in random sequence. AHI-RP were compared to AHI-PSG, and therapeutic decisions based on AHI-RP and AHI-PSG were formulated and analyzed using clinical details derived from the patient's clinic letter. RESULTS: Bland Altman analysis showed that in lab RP underestimated the AHI despite more accurate estimates of TST. This underestimation was due to missed hypopneas causing arousals without desaturation. Basing the therapeutic management decision on RP instead of PSG results changed the clinical management in 23% of all patients. The clinical management for patients in groups A and D was unaffected. However, 27.5% of patients in group B would have been given no treatment, as they would be diagnosed as having no OSA (AHI < 1/h TST) when they should have received a trial of anti-inflammatory therapy or been referred for ear, nose, and throat (ENT) review. Sixty percent of patients in group C would have received either a trial of medical treatment to treat mild OSA or no treatment, instead of referral to ENT services or commencement of continuous positive airway pressure. CONCLUSION: Apnea-hypopnea index (AHI) is underestimated in respiratory polygraphy (RP), and the disparity in AHI-RP and AHI-polysomnography can significantly affect clinical management decisions, particularly in children with mild and moderate obstructive sleep apnea (1 < AHI < 10/h total sleep time).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.3392

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 185

Metadata

Authors
Tan, H.-L., Gozal, D., Ramirez, H. M., Bandla, H. P. R., & Kheirandish-Gozal, L.
Venue
Sleep
Published
2014-02-01
Volume
37
Issue
2
Pages
255-260
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2024740006
Cited by
185
References
6
FWCI
8.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Overnight Polysomnography versus Respiratory Polygraphy in the Diagnosis of Pediatric Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.5665/sleep.3392
The paper
Tan, H.-L., Gozal, D., Ramirez, H. M., Bandla, H. P. R., & Kheirandish-Gozal, L. (2014). Overnight Polysomnography versus Respiratory Polygraphy in the Diagnosis of Pediatric Obstructive Sleep Apnea. Sleep. https://doi.org/10.5665/sleep.3392

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.