STUDY OBJECTIVES: To investigate effectiveness, long-term compliance, and effects on subjective sleep of the Sleep Position Trainer (SPT) in patients with position-dependent obstructive sleep apnea syndrome (POSAS). DESIGN: Prospective, multicenter cohort study. PATIENTS OR PARTICIPANTS: Adult patients with mild and moderate POSAS were included. INTERVENTIONS: Patients were [corrected] asked to use the SPT for 6 mo. At baseline and after 1, 3, and 6 mo, questionnaires would be completed: Epworth Sleepiness Scale (ESS), Pittsburgh Sleep Quality Index (PSQI), Functional Outcomes of Sleep Questionnaire (FOSQ), and questions related to SPT use. MEASUREMENTS AND RESULTS: One hundred forty-five patients were included. SPT use and SPT data could not be retrieved in 39 patients. In the remaining 106 patients, median percentage of supine sleep decreased rapidly during SPT's training phase (day 3 to 9) to near-total avoidance of supine sleep. This decrease was maintained during the following months of treatment (21% at baseline versus 3% at 6 mo). SPT compliance, defined as more than 4 h of nightly use, was 64.4%. Regular use, defined as more than 4 h of usage over 5 nights/w, was 71.2%. Subjective compliance and regular use were 59.8% and 74.4%, respectively. Median ESS (11 to 8), PSQI (8 to 6), and FOSQ (87 to 103) values significantly improved compared with baseline. CONCLUSIONS: Positional therapy using the Sleep Position Trainer (SPT) effectively diminished the percentage of supine sleep and subjective sleepiness and improved sleep related quality of life in patients with mild to moderate position-dependent obstructive sleep apnea syndrome. SPT treatment appeared to have sustained effects over 6 months. SPT compliance and regular use rate were relatively good. Subjective and objective compliance data corresponded well. The lack of a placebo-controlled group limited the efficacy of conclusions. CITATION: van Maamen JP, de Vries N. Long-term effectiveness and compliance of positional therapy with the Sleep Position Trainer in the treatment of positional obstructive sleep apnea syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.3840

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 20

  1. Kendzerska, 2014, Untreated obstructive sleep apnea and the risk for serious long-term adverse outcomes: A systematic review, Sleep Med Rev, 18, 49, 10.1016/j.smrv.2013.01.003 · DOI · Paper page
  2. Richard, 2006, The role of sleep position in obstructive sleep apnea syndrome, Eur Arch Otorhinolaryngol, 263, 946, 10.1007/s00405-006-0090-2 · DOI · Paper page
  3. Mador, 2005, Prevalence of positional sleep apnea in patients undergoing polysomnography, Chest, 128, 2130, 10.1378/chest.128.4.2130 · DOI · Paper page
  4. Permut, 2010, Comparison of positional therapy to CPAP in patients with positional obstructive sleep apnea, J Clin Sleep Med, 6, 238, 10.5664/jcsm.27820 · DOI · Paper page
  5. van Maanen, 2013, The sleep position trainer: a new treatment for positional obstructive sleep apnoea, Sleep Breath, 17, 771, 10.1007/s11325-012-0764-5 · DOI
  6. Bignold, 2011, Accurate position monitoring and improved supine-dependent obstructive sleep apnea with a new position recording and supine avoidance device, J Clin Sleep Med, 7, 376, 10.5664/JCSM.1194 · DOI
  7. van Maanen, 2012, Evaluation of a new simple treatment for positional sleep apnoea patients, J Sleep Res, 21, 322, 10.1111/j.1365-2869.2011.00974.x · DOI · Paper page
  8. Bignold, 2009, Poor long-term patient compliance with the tennis ball technique for treating positional obstructive sleep apnea, J Clin Sleep Med, 5, 428, 10.5664/jcsm.27597 · DOI · Paper page
  9. Clark, 2009, Mandibular advancement devices and sleep disordered breathing, Sleep Med Rev, 2, 163, 10.1016/S1087-0792(98)90019-3 · DOI
  10. Buysse, 2009, The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research, Psychiatry Res, 28, 193, 10.1016/0165-1781(89)90047-4 · DOI · Paper page
  11. Cartwright, 2009, The effects of sleep posture and sleep stage on apnea frequency, Sleep, 14, 351, 10.1093/sleep/14.4.351 · DOI · Paper page
  12. Kushida, 2009, Effects of continuous positive airway pressure on neurocognitive function in obstructive sleep apnea patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES), Sleep, 35, 1593, 10.5665/sleep.2226 · DOI · Paper page
  13. Vanderveken, 2009, Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing, Thorax, 68, 91, 10.1136/thoraxjnl-2012-201900 · DOI · Paper page
  14. Dieltjens, 2009, Objectively measured vs. selfreported compliance during oral appliance therapy for sleep-disordered breathing, Chest, 144, 1495, 10.1378/chest.13-0613 · DOI · Paper page
  15. Nakazawa, 2009, Treatment of sleep apnea with prosthetic mandibular advancement (PMA), Sleep, 15, 499, 10.1093/sleep/15.6.499 · DOI · Paper page
  16. Wenzel, 2009, Effektivitat und Langzeit-Compliance der Therapie mit Ruckenlage-Verhinderungsweste bei obstruktiver Schlafapnoe, Laryngorhinootologie, 86, 579, 10.1055/s-2007-966179 · DOI · Paper page
  17. Heinzer, 2009, Positional therapy for obstructive sleep apnea: an objective measurement of patients' usage and efficacy at home, Sleep Med, 13, 425, 10.1016/j.sleep.2011.11.004 · DOI
  18. Leseux, 2009, [Education of patients with sleep apnea syndrome: Feasibility of a phone coaching procedure Phone-coaching and SAS], Rev Mal Respir, 29, 40, 10.1016/j.rmr.2011.11.001 · DOI
  19. Willemin, 2009, [Effects of an educational program in non-adherent apneic patients treated with continuous positive airway pressure], Rev Pneumol Clin, 69, 70, 10.1016/j.pneumo.2012.12.009 · DOI
  20. Fuchs, 2009, Adherence to continuous positive airway pressure therapy for obstructive sleep apnea: impact of patient education after a longer treatment period, Respiration, 80, 32, 10.1159/000243161 · DOI

Cited by

See all 139

Metadata

Authors
van Maanen, J. P., & de Vries, N.
Venue
Sleep
Published
2014-07-01
Volume
37
Issue
7
Pages
1209-1215
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1892297604
Cited by
139
References
18
FWCI
10.11
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.