CoChat

Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System

Open access
Punjabi, Naresh M., Shifa, Naima, Dorffner, Georg, Patil, Susheel, Pien, Grace, Aurora, Rashmi N. · 2015 · Sleep
Cited by 67

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. DESIGN: The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. SETTING: Clinical sleep laboratories. MEASUREMENTS AND RESULTS: A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90-0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91-0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. CONCLUSION: Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated scoring platforms provide a viable complement of tools in the diagnostic armamentarium of sleep medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.5046

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Punjabi, N. M., Shifa, N., Dorffner, G., Patil, S., Pien, G., & Aurora, R. N.
Venue
Sleep
Published
2015-10-01
Volume
38
Issue
10
Pages
1555-1566
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2402366071
Cited by
67
References
5
FWCI
7.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.