CoChat

A Direct Assay for Measuring Free 25-Hydroxyvitamin D

Heureux, Nicolas, Lindhout, Ernst, Swinkels, Leon · 2017 · Journal of AOAC INTERNATIONAL
Cited by 49

The DOI matches its Crossref record.

Abstract

Recent studies suggest that the concentration andgenotype of vitamin D binding protein (VDBP) are important factors that determine the bioavailability of25-hydroxyvitamin D [25(OH)D] in blood. Accumulatingdata indicate that, e.g., in pregnant women, hemodialysis patients, chronic kidney disease, liver failure, and bladder and pancreatic cancers, the measurement of free 25(OH)D in serum provides more relevant diagnostic information than measurement of total 25(OH)D. The aim of this study was to develop and validate an ELISA for direct measurement of free 25(OH)D in serum. A simple and direct ELISA was developed, based on a two-step immunoassay procedure performed ina microtiter plate. The assay has been characterizedin terms of precision (4–10% CV, according toconcentration), sensitivity (limits of blank = 0.5–1.0 pg/mL and LODs = 1.3–1.8 pg/mL), accuracy (correlation to dialysis, ELISA = 0.99xdialysis-0.5 pg/mL, r2 = 0.74), cross-reactivity of the antibody for the D2 form (77%),and addition of both VDBP and albumin (35–38%recovery upon addition of VDBP, 53–58% upon addition of albumin). The assay has already been usedin multiple studies, including its comparison with calculation methods and in studies of patients with liver failure, different ethnic groups, supplemented mice, respiratory diseases, and obesity. The free 25(OH)D ELISA can be used in studies as a valuable toolto establish the clinical relevance of free 25(OH)D.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5740/jaoacint.17-0084

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 49

Metadata

Authors
Heureux, N., Lindhout, E., & Swinkels, L.
Venue
Journal of AOAC INTERNATIONAL
Published
2017-09-01
Volume
100
Issue
5
Pages
1318-1322
ISSN
  • 1060-3271 (ISSN-L)
  • 1944-7922
OpenAlex
W2613499645
Cited by
49
References
0
FWCI
5.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Direct Assay for Measuring Free 25-Hydroxyvitamin D. https://app.cochat.ai/papers/10.5740/jaoacint.17-0084
The paper
Heureux, N., Lindhout, E., & Swinkels, L. (2017). A Direct Assay for Measuring Free 25-Hydroxyvitamin D. Journal of AOAC INTERNATIONAL. https://doi.org/10.5740/jaoacint.17-0084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.