The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Open accessAbstract
Rich useful information can be obtained from the muscles and researchers can use such information in a wide class of clinical and engineering applications by measuring surface electromyography (EMG) signals (Merletti & Parker, 2004). Normally, EMG signals are acquired by surface electrodes that are placed on the skin superimposed on the targeted muscle. In order to use the EMG signal as a diagnosis signal or a control signal, a feature is often extracted before performing analysis or classification stage (Phinyomark et al., 2012a) because a lot of information, both useful information and noise (Phinyomark et al., 2012b), is contained in the raw EMG data. An EMG feature is a distinct characteristic of the signal that can be described or observed quantitatively, such as being large or small, spiky or smooth, and fast or slow. Generally, EMG features can be computed in numerical form from a finite length time interval and can change as a function of time, i.e. a voltage or a frequency. They can be computed in several domains, such as time domain, frequency domain, timefrequency and time-scale representations (Boostani & Moradi, 2003). However, frequencydomain features show the better performance than other-domain features in case of the assessing muscle fatigue (Al-Mulla et al., 2012). Mean frequency (MNF) and median frequency (MDF) are the most useful and popular frequency-domain features (Phinyomark et al., 2009) and frequently used for the assessment of muscle fatigue in surface EMG signals (Cifrek et al., 2009).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Self-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Self-citationElectromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Myoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 882
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
Self-citationPhysiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Changes in surface EMG parameters during static and dynamic fatiguing contractions
Masuda, K., Masuda, T., Sadoyama, T., Inaki, M., & Katsuta, S. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00021-2 · Cited by 375
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Electromyography: Physiology, Engineering and Non-Invasive Applications
Madhavan, G. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8160-y · Cited by 362
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Karlsson, S., Yu, J., & Akay, M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821766 · Cited by 358
A Novel Feature Extraction for Robust EMG Pattern Recognition
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0912.3973 · Cited by 351
Self-citationElectromyogram power spectra frequencies associated with motor unit recruitment strategies
Solomonow, M., Baten, C., Smit, J., Baratta, R., Hermens, H., D'Ambrosia, R., & Shoji, H. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1177 · Cited by 333
Localized muscle fatigue--definiton and measurement.
Chaffin, D. B. (1973) · PubMed · Cited by 330
Motor unit recruitment strategies investigated by surface EMG variables
Farina, D., Fosci, M., & Merletti, R. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.235 · Cited by 318
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Motor unit activity and surface electromyogram power spectrum during increasing force of contraction
Moritani, T., & Muro, M. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00690890 · Cited by 301
Signal characteristics of EMG during fatigue
Viitasalo, J. H. T., & Komi, P. V. (1977) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421697 · Cited by 295
Bonato, P., Roy, S. H., Knaflitz, M., & de Luca, C. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930899 · Cited by 284
Inference of motor unit recruitment order in voluntary and electrically elicited contractions
Knaflitz, M., Merletti, R., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.4.1657 · Cited by 251
Bilodeau, M., Schindler-Ivens, S., Williams, D. M., Chandran, R., & Sharma, S. S. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00050-0 · Cited by 249
Modeling of surface myoelectric signals. I. Model implementation
Merletti, R., Lo Conte, L., Avignone, E., & Guglielminotti, P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771190 · Cited by 208
PETROFSKY, J. S., GLASER, R. M., PHILLIPS, C. A., LIND, A. R., & WILLIAMS, C. (1982) · Ergonomics · doi:10.1080/00140138208924942 · Cited by 207
Rainoldi, A., Galardi, G., Maderna, L., Comi, G., Lo Conte, L., & Merletti, R. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00042-x · Cited by 203
Frequency analysis of the surface electromyogram during sustained isometric contractions
Petrofsky, J. S., & Lind, A. R. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00422448 · Cited by 198
Effect of elbow joint angle on force–EMG relationships in human elbow flexor and extensor muscles
Doheny, E. P., Lowery, M. M., FitzPatrick, D. P., & O’Malley, M. J. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.03.006 · Cited by 185
Potvin, J. R. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.144 · Cited by 184
Petrofsky, J. S., & Lind, A. R. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421098 · Cited by 179
ACTIVITY OF MOTOR UNITS DURING CONCENTRIC AND ECCENTRIC CONTRACTIONS
MORITANI, T., MURAMATSU, S., & MURO, M. (1988) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-198812000-00003 · Cited by 178
Influence of fatigue on EMG/force ratio and cocontraction in cycling
HAUTIER, C. A., ARSAC, L. M., DEGHDEGH, K., SOUQUET, J., BELLI, A., & LACOUR, J.-R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200004000-00017 · Cited by 168
Allison, G. T., & Fujiwara, T. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(02)00033-5 · Cited by 149
Median frequency of the myoelectric signal: Effects of muscle ischemia and cooling
Merletti, R., Sabbahi, M. A., & Luca, C. J. D. (1984) · European Journal of Applied Physiology · doi:10.1007/bf01015206 · Cited by 149
Time-frequency methods applied to muscle fatigue assessment during dynamic contractions
Knaflitz, M., & Bonato, P. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00009-7 · Cited by 146
Myoelectric and Mechanical Manifestations of Muscle Fatigue in Voluntary Contractions
Merletti, R., & Roy, S. H. (1996) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1996.24.6.342 · Cited by 145
Thongpanja, S., Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2013) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eee.19.3.3697 · Cited by 138
Self-citationPhinyomark, A., Hirunviriya, S., Limsakul, C., & Phukpattaranont, P. (2010) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · Cited by 134
Self-citationMyoelectric power spectrum dependence on muscular contraction level of elbow flexors
Hagberg, M., & Ericson, B. E. (1982) · European Journal of Applied Physiology · doi:10.1007/bf00422976 · Cited by 132
Mannion, A. F., Dolan, P., Mannion, A. F., & Dolan, P. (1996) · European Journal of Applied Physiology · doi:10.1007/bf02337721 · Cited by 127
Temporal vs. spectral approach to feature extraction from prehensile EMG signals
Du, S., & Vuskovic, M. I. (2005) · doi:10.1109/iri.2004.1431485 · Cited by 111
EMG assessment of back muscle function during cyclical lifting
Roy, S. H., Bonato, P., & Knaflitz, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00010-8 · Cited by 105
GA-based Feature Subset Selection for Myoelectric Classification
Oskoei, M. A., & Hu, H. (2006) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2006.340145 · Cited by 100
Self-citationMonitoring surface EMG spectral changes by the zero crossing rate
Inbar, G. F., Paiss, O., Allin, J., & Kranz, H. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441600 · Cited by 85
Ravier, P., Buttelli, O., Jennane, R., & Couratier, P. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.08.008 · Cited by 74
Gerdle, B. U. C., Eriksson, N. E., & Brundin, L. (1990) · PubMed · Cited by 68
Changes in the myoelectric signal (MES) power spectra during dynamic contractions
Shankar, S., Gander, R. E., & Brandell, B. R. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90193-4 · Cited by 66
Arnall, F. A., Koumantakis, G. Α., Oldham, J. A., & Cooper, R. G. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr551oa · Cited by 53
Measurement and analysis of surface myoelectric signals during fatigued cyclic dynamic contractions
Cifrek, M., Tonković, S., & Medved, V. (2000) · Measurement · doi:10.1016/s0263-2241(99)00059-7 · Cited by 52
The clinical use of surface EMG.
Hermens, H. J., Boon, K. L., & Zilvold, G. (1984) · PubMed · Cited by 52
Influence of motor unit firing statistics on the median frequency of the EMG power spectrum
Boxtel, A. V., & Schomaker, L. (1984) · European Journal of Applied Physiology · doi:10.1007/bf00433394 · Cited by 50
Oskoei, M. A., Hu, H., & Gan, J. Q. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649153 · Cited by 45
Self-citationBien, Z. N. (2000) · Cited by 45
Jt, V., & Komi, P. V. (1978) · PubMed · Cited by 44
Zhang, Z. G., Liu, H. T., Chan, S. C., Luk, K. D. K., & Hu, Y. S. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.007 · Cited by 42
Influence of gender on the EMG power spectrum during an increasing force level
Bilodeau, M., Arsenault, B. A., Gravel, D., & Bourbonnais, D. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90009-8 · Cited by 42
The Usefulness of Wavelet Transform to Reduce Noise in the SEMG Signal
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · InTech eBooks · doi:10.5772/25757 · Cited by 41
Self-citationHagberg, C., & Hagberg, M. (1989) · European Journal of Applied Physiology · doi:10.1007/bf00418511 · Cited by 40
Larivière, C., Arsenault, B. A., Gravel, D., Gagnon, D., & Loisel, P. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00037-7 · Cited by 37
The effects of four time-varying factors on the mean frequency of a myoelectric signal
Cechetto, A. D., Parker, P. A., & Scott, R. N. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00010-4 · Cited by 36
Clancy, E. A., Farina, D., & Merletti, R. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.11.002 · Cited by 36
Muro, M., Nagata, A., Murakami, K., & Moritani, T. (1982) · PubMed · Cited by 36
Wavelet De-Noising of Electromyography
Qingju, Z., & Zhizeng, L. (2006) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2006.257406 · Cited by 34
Leunkeu, A. N., Keefer, D. J., Miladi, I., & Ahmaidi, S. (2009) · Journal of Child Neurology · doi:10.1177/0883073809338734 · Cited by 33
Effect of muscle length on surface EMG wave forms in isometric contractions
Okada, M. (1987) · European Journal of Applied Physiology · doi:10.1007/bf00417780 · Cited by 31
sEMG Techniques to Detect and Predict Localised Muscle Fatigue
Reaz, M. B. I., Sepúlveda, F., & Colley, M. (2012) · InTech eBooks · doi:10.5772/25678 · Cited by 29
Single motor unit myoelectric signal analysis with nonstationary data
Englehart, K. B., & Parker, P. A. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284928 · Cited by 28
A preliminary investigation assessing the viability of classifying hand postures in seniors
Tavakolan, M., Xiao, Z. G., & Menon, C. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-79 · Cited by 26
Phinyomark, A., Hirunviriya, S., Nuidod, A., Phukpattaranont, P., & Limsakul, C. (2011) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-21729-6_183 · Cited by 25
Self-citationMerletti, R., Conte, L. L., Cisari, C., & Massazza, U. (1993) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(93)90114-p · Cited by 24
Cited by
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
An efficient security risk estimation technique for Risk-based access control model for IoT
Atlam, H. F., & Wills, G. B. (2019) · Internet of Things · doi:10.1016/j.iot.2019.100052 · Cited by 60
Imperceptible liquid metal based tattoo for Human-Machine interface on hairy skin
Lin, W., Ai, L., Wang, Y., Yang, X., Liao, J., Pan, Q., Hong, Y., Liu, S., Long, Z., Khoo, B. L., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.151595 · Cited by 40
Metadata
- Authors
- Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C.
- Venue
- Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges
- Publisher
- InTech
- Published
- 2012-10-17
- OpenAlex
- W1596975731
- Cited by
- 294
- References
- 72
- FWCI
- 16.03
- Type
- book chapter
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.