Titanium and Titanium Alloys as Biomaterials
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Bone and its several associated elements – cartilage, connective tissue, vascular elements and nervous components – act as a functional organ. They provide support and protection for soft tissues and act together with skeletal muscles to make body movements possible. Bones are relatively rigid structures and their shapes are closely related to their functions. Bone metab‐ olism is mainly controlled by the endocrine, immune and neurovascular systems, and its metabolism and response to internal and external stimulations are still under assessment [1].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030
Kurtz, S., Ong, K., Lau, E., Mowat, F., & Halpern, M. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00012 · Cited by 8,698
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Titanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510 · cited 1×
“Thus, development of appropriate material with high longevity, superior corrosion resistance in body environment, excellent combination of high strength and low Young ́s modulus, high fatigue and wear resistance, high ductibility, excellent biocompatibility and be without citotoxicity is highly essential [8] [9].”
BackgroundSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487 · cited 1×
“Their lower Young ́s modulus, superior biocompatibility and better corrosion resistance in comparison with conventional stainless steels and cobalt-based alloys, make them an ideal choice for bioapplications [26].”
BackgroundOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · cited 1×
“patibility of a material [11].”
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642 · cited 1×
“Biomaterials are used in different parts of the human body as artificial valves in the heart, stents in blood vessels, replacement implants in shoulders, knees, hips, elbows, ears and dental structures [3] [4] [5].”
Brunette, D. M., Tengvall, P., Textor, M., & Thomsen, P. (2001) · Engineering Materials · doi:10.1007/978-3-642-56486-4 · Cited by 1,547
Journal of Materials Science: Materials in Medicine
(2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/10856.1573-4838 · Cited by 1,219
Journal of Biomedical Materials Research
(2010) · Journal of Biomedical Materials Research · doi:10.1002/(issn)1097-4636 · Cited by 1,189
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
Kim, H.-M., Miyaji, F., Kokubo, T., & Nakamura, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<409::aid-jbm14>3.0.co;2-b · Cited by 1,005 · cited 1×
“A strong and durable bone to implant connection can be achieved by the formation of a stable bone tissue at the bone-implant interface by proper implant surface treatments, as can be electrochemical deposition, dipping and physical vapor deposition techniques [42].”
BackgroundCorrosion of Metal Orthopaedic Implants*
Jacobs, J. J., Gilbert, J. L., & Urban, R. M. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199802000-00015 · Cited by 967
The use of titanium for medical applications in the USA
Wang, K. (1996) · Materials Science and Engineering A · doi:10.1016/0921-5093(96)10243-4 · Cited by 851 · cited 1×
“Thus, development of appropriate material with high longevity, superior corrosion resistance in body environment, excellent combination of high strength and low Young ́s modulus, high fatigue and wear resistance, high ductibility, excellent biocompatibility and be without citotoxicity is highly essential [8] [9].”
BackgroundCorrelation between substratum roughness and wettability, cell adhesion, and cell migration
Lampin, M., Warocquier-Cl�rout, R., Legris, C., Degrange, M., & Sigot-Luizard, M. F. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<99::aid-jbm12>3.0.co;2-e · Cited by 777
Biocompatibility of clinical implant materials
Williams, D. F. (1981) · CRC Press eBooks · Cited by 773
Preparation of bioactive titanium metal via anodic oxidation treatment
Yang, B., Uchida, M., Kim, H.-M., Zhang, X., & Kokubo, T. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00626-4 · Cited by 730 · cited 1×
“The influence of electrolyte characteristics on the phase composition of PEO films on titanium has previously been studied [89] [90].”
BackgroundEffects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534
Biomaterials: Principles and Applications
Park, J. B., & Bronzino, J. D. (2002) · CRC Press eBooks · doi:10.1201/9781420040036 · Cited by 514
Chemical modification of titanium surfaces for covalent attachment of biological molecules
Nanci, A., Wuest, J. D., Peru, L., Brunet, P., Sharma, V., Zalzal, S., & McKee, M. D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · Cited by 503 · cited 1×
“Furthermore, there are alternative methods to improve the biocompatibility such as biocom‐ patible chemicals [54] and materials such as ceramics for coating.”
MethodStructure and composition of passive titanium oxide films
Pouilleau, J., Devilliers, D., Garrido, F., Durand-Vidal, S., & Mahé, É. (1997) · Materials Science and Engineering B · doi:10.1016/s0921-5107(97)00043-3 · Cited by 376 · cited 1×
“The stability of the oxide depends strongly on the composition structure and thickness of the film [75].”
BackgroundThe Role of Implant Surface Characteristics in the Healing of Bone
Kieswetter, K., Schwartz, Z., Dean, D. D., & Boyan, B. D. (1996) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411960070040301 · Cited by 338
Balancing osteoblast functions and bacterial adhesion on functionalized titanium surfaces
Neoh, K. G., Hu, X., Zheng, D., & Kang, E. T. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.018 · Cited by 330 · cited 3×
“The natural oxide is thin (about 3–10nm in thickness [39] ) amorphous and stoichiometrically defective.”
BackgroundInfluentialCorrosion and surface chemistry of metals
(2007) · Choice Reviews Online · doi:10.5860/choice.45-0897 · Cited by 295 · cited 1×
“Metals in the passive state (passive metals) have a thin oxide layer (TiO2 in case of titanium) on their surface, the passive film, which separates the metal from its environment [38].”
BackgroundAnisotropy of Young's modulus of bone
Katz, J. L. (1980) · Nature · doi:10.1038/283106a0 · Cited by 264
Corrosion and Surface Chemistry of Metals
Landolt, D. (2007) · EPFL Press eBooks · doi:10.1201/9781439807880 · Cited by 262
Hydroxyapatite-Coated Porous Titanium for Use as an Orthopedic Biologic Attachment System
Cook, S. D., THOMAS, K. A., Kay, J. F., & Jarcho, M. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198805000-00038 · Cited by 226
Vlacic-Zischke, J., Hamlet, S. M., Friis, T., Tonetti, M. S., & Ivanovski, S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.025 · Cited by 199
Lange, R., Lüthen, F., Beck, U., Rychly, J., Baumann, A., & Nebe, B. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00047-3 · Cited by 167
Eriksson, C., Lausmaa, J., & Nygren, H. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00382-3 · Cited by 161
critic Al rE vi EWs in Or Al biOlOgY & MEDicin E
Kim, S. J., & Act, A. (2016) · Cited by 140
Sul, Y., Johansson, C. B., Kang, Y.-M., Jeon, D., & Albrektsson, T. O. (2002) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2002.tb00156.x · Cited by 107
Kim, H., Kim, S. H., Kim, M.-G., Lee, E. J., Oh, H. G., Oh, W. M., Park, S. W., Kim, W. J., Lee, G. J., Choi, N. G., et al. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30327 · Cited by 94
Huang, P., Xu, K., & Han, Y. N. (2004) · Materials Letters · doi:10.1016/j.matlet.2004.09.045 · Cited by 89 · cited 1×
“Oxidation remains the most popular technique for the surface modification of Ti alloys; these oxide layers on titanium are commonly produced by either heat treatment [48] [49] [50] or electrolytic anodizing [51].”
Cemented versus cementless hip arthroplasty A review of prosthetic biocompatibility
Santavirta, S. S., Gristina, A. G., & Konttinen, Y. T. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154831 · Cited by 82
Titanium surface modification techniques for dental implants—From microscale to nanoscale
Subramani, K., Mathew, R. T., & Pachauri, P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-812291-4.00006-6 · Cited by 46
Genetic Potential of Interfacial Guided Osteogenesis in Implant Devices.
Letić-Gavrilović, A., SCANDURRA, R., & Abe, K. (2000) · Dental Materials Journal · doi:10.4012/dmj.19.99 · Cited by 41 · cited 1×
“The biological response to titanium depends on the surface chemical composition and the ability of titanium oxides to absorb molecules and incorporate elements [92].”
BackgroundBiomechanical evaluation of a titanium implant surface conditioned by a hydroxide ion solution
Stadlinger, B., Ferguson, S. J., Eckelt, U., Mai, R., Lode, A. T., Loukota, R. A., & Schlottig, F. (2010) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.bjoms.2010.11.013 · Cited by 41
Nanostructured Materials for Inhibition of Bacterial Adhesion in Orthopedic Implants: A Minireview
Montanaro, L., Campoccia, D., & Arciola, C. R. (2008) · The International Journal of Artificial Organs · doi:10.1177/039139880803100904 · Cited by 38
Titanium Surface Modification Techniques for Dental Implants—From Microscale to Nanoscale
Subramani, K., & Mathew, R. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-7862-1.00006-7 · Cited by 28
Hard Tissue: Biomaterial Interactions
(2008) · CRC Press eBooks · doi:10.1081/e-ebbe2-120041273 · Cited by 21 · cited 1×
“Bone metab‐ olism is mainly controlled by the endocrine, immune and neurovascular systems, and its metabolism and response to internal and external stimulations are still under assessment [1].”
Background
Cited by
Design and 3D-printing of titanium bone implants: brief review of approach and clinical cases
Popov, V. V., Muller-Kamskii, G., Kovalevsky, A., Dzhenzhera, G., Strokin, E., Kolomiets, A., & Ramon, J. (2018) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0080-5 · Cited by 183
Metadata
- Authors
- de Viteri, V. S., & Fuentes, E.
- Venue
- Tribology - Fundamentals and Advancements
- Publisher
- InTech
- Published
- 2013-05-22
- OpenAlex
- W1547693583
- Cited by
- 166
- References
- 40
- FWCI
- 15.64
- Type
- book chapter
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.