CoChat

Reduction of Blood Loss From Laboratory Testing in Hospitalized Adult Patients Using Small-Volume (Pediatric) Tubes

Sanchez-Giron, Francisco, Alvarez-Mora, Francisco · 2008 · Archives of Pathology & Laboratory Medicine
Cited by 92

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Context. —Blood loss from laboratory testing (BLLT) can be significant in hospitalized patients. It is a common practice to draw full large-volume tubes of blood from adults. Objective. —To determine whether BLLT occurred when a small-volume (pediatric) blood collection tube (SVT) was substituted for each large-volume blood collection tube and to note whether an adequate sample still was obtained. Design. —During 2 consecutive weeks, hospital test requisitions were reviewed to collect patient demographics, tests requested, and number and type of tubes obtained. The amount of blood collected and BLLT per patient were calculated. Reduced sample requirements were calculated, and phlebotomists and ward nurses were required to use SVTs. After 2 weeks of familiarization, data were collected as previously described. Laboratory technicians logged problems related to the use of SVTs. Results. —Baseline: 227 patients had 664 requisitions, and median BLLT per patient was 13.5 mL (interquartile range [IQR], 7.6–27.3 mL). In critical care patients, the median was 19.9 mL (IQR, 12.0–35.8 mL), and maximum BLLT was 159.8 mL. Intervention phase: 246 patients had 696 requisitions, median BLLT was 3.7 mL (IQR, 1.2–6.3 mL; P < .001). In critical care patients, the median was 5.1 mL (IQR, 2.3–10.9 mL), and maximum BLLT was 61.8 mL ( P < .001). All tests requested could be performed using SVTs, and no additional blood collections were required. Use of SVTs reduced overall BLLT per patient by 73% and by 74% in critical care patients. Conclusions. —By decreasing the size of the blood collection tube for adults, we were able to markedly reduce BLLT without noting any insufficient specimen volumes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/132.12.1916

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 92

Metadata

Authors
Sanchez-Giron, F., & Alvarez-Mora, F.
Venue
Archives of Pathology & Laboratory Medicine
Published
2008-12
Volume
132
Issue
12
Pages
1916-1919
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W2170206187
Cited by
92
References
1
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of Blood Loss From Laboratory Testing in Hospitalized Adult Patients Using Small-Volume (Pediatric) Tubes. https://app.cochat.ai/papers/10.5858/132.12.1916
The paper
Sanchez-Giron, F., & Alvarez-Mora, F. (2008). Reduction of Blood Loss From Laboratory Testing in Hospitalized Adult Patients Using Small-Volume (Pediatric) Tubes. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/132.12.1916

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.