CoChat

Use of Buccal Cells Collected in Mouthwash as a Source of DNA for Clinical Testing

Heath, Ellen M., Morken, Nathaniel W., Campbell, Kristen A., Tkach, Dennis, Boyd, Erin A., Strom, Daniel A. · 2001 · Archives of Pathology & Laboratory Medicine
Cited by 109

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Context. —To maximize the participation rate in population genetic studies, alternatives to invasive whole blood collection are increasing. One such alternative is buccal epithelial cell collection, which, in contrast to venipuncture and finger sticks, is painless. Buccal cells, if collected and purified efficiently, offer an acceptable source for DNA to be used in research and clinical applications. Objective. —To develop a noninvasive sampling method for collecting cells for routine DNA testing in a clinical laboratory setting. Design. —Five factors were used to evaluate several brands of mouthwash: (1) compatibility with the DNA purification chemistry, (2) DNA yield, (3) DNA quality, (4) DNA stability at room temperature, and (5) mouthwash taste. Next, an optimization study was undertaken to maximize DNA yield. Finally, a validation study was undertaken with the optimized protocol to test a panel of 14 donors for DNA yield and performance and to test for the stability of DNA held in mouthwash. Setting. —Industrial research and development laboratory. Results. —Of 5 mouthwashes tested, Scope brand mouthwash received the highest overall ranking. The addition of proteinase K and glycogen to the protocol significantly enhanced DNA yields, with a test panel (n = 14) giving a range of 12 to 60 μg of DNA per donor. In a 4-week room temperature stability study, the DNA in mouthwash samples was found to be stable for at least 2 weeks. Conclusion. —A clinically validated DNA purification chemistry was adapted to a noninvasive specimen collection method. This method used a commercially available mouthwash, Scope, to collect buccal epithelial cells for the preparation of high-quality DNA in high yield.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/2001-125-0127-uobcci

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 109

Metadata

Authors
Heath, E. M., Morken, N. W., Campbell, K. A., Tkach, D., Boyd, E. A., & Strom, D. A.
Venue
Archives of Pathology & Laboratory Medicine
Published
2001-01
Volume
125
Issue
1
Pages
127-133
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W1949380226
Cited by
109
References
1
FWCI
2.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Buccal Cells Collected in Mouthwash as a Source of DNA for Clinical Testing. https://app.cochat.ai/papers/10.5858/2001-125-0127-uobcci
The paper
Heath, E. M., Morken, N. W., Campbell, K. A., Tkach, D., Boyd, E. A., & Strom, D. A. (2001). Use of Buccal Cells Collected in Mouthwash as a Source of DNA for Clinical Testing. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2001-125-0127-uobcci

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.