The DOI matches its Crossref record.
pH Effects on Measurements of Ionized Calcium and Ionized Magnesium in Blood
Abstract
Context.—It is well known that the concentration of ionized calcium in blood is affected by the pH of the specimen, since hydrogen ions compete with calcium for binding sites on albumin and other proteins. However, the relationship between pH and ionized magnesium concentration is not as well characterized. Objective.—To determine the effects of pH on ionized magnesium concentration over a wide range of pH values in serum or plasma. Design.—Both ionized calcium and ionized magnesium concentrations were measured in 3 sets of samples. (1) Pools of serum or whole blood at different pH values (7.20–7.60) achieved by adding a constant volume of acid or base (diluted solutions of either hydrochloric acid or sodium hydroxide) plus saline. These pools consisted of 2 serum and 3 heparinized whole blood pools collected from leftover blood remaining in clinical specimens in the Clinical Chemistry and Blood Gas Laboratories, respectively, at Duke University Medical Center. (2) Five whole blood specimens obtained from apparently healthy individual donors. (3) Twenty-six whole blood specimens obtained from individual patients (leftover blood from the Blood Gas Laboratory) in which pH was varied by in vitro loss or gain of carbon dioxide. Results.—Both ionized calcium and ionized magnesium concentrations decreased as the pH in the specimen increased, indicating the stronger binding of these ions with proteins in the more alkaline environment. Conclusion.—We conclude that the rate of change of ionized magnesium concentration with pH change (0.12 mmol/L per pH unit) is significantly less than that of ionized calcium (0.36 mmol/L per pH unit). Furthermore, our findings indicate that if adjustment to pH 7.40 is necessary, the ionized magnesium test results need to be adjusted when pH is markedly abnormal, as is sometimes done for ionized calcium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Controlled drug delivery vehicles for cancer treatment and their performance
Senapati, S., Mahanta, A. K., Kumar, S., & Maiti, P. (2018) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-017-0004-3 · Cited by 2,167
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Lier, H., Krep, H., Schroeder, S., & Stuber, F. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e318187e15b · Cited by 334
Kalghatgi, S. U., Fridman, G., Cooper, M., Nagaraj, G., Peddinghaus, M., Balasubramanian, M., Vasilets, V. N., Gutsol, A. F., Fridman, A., & Friedman, G. (2007) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2007.905953 · Cited by 306
Morgan, T. T., Muddana, H. S., Altinoǧlu, E. İ., Rouse, S. M., Tabaković, A., Tabouillot, T., Russin, T. J., Shanmugavelandy, S. S., Butler, P. J., Eklund, P. C., et al. (2008) · Nano Letters · doi:10.1021/nl8019888 · Cited by 295
Metadata
- Authors
- Wang, S., McDonnell, E. H., Sedor, F. A., & Toffaletti, J. G.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2002-08-01
- Volume
- 126
- Issue
- 8
- Pages
- 947-950
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2128737493
- Cited by
- 191
- References
- 0
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH Effects on Measurements of Ionized Calcium and Ionized Magnesium in Blood. https://app.cochat.ai/papers/10.5858/2002-126-0947-peomoi
- The paper
- Wang, S., McDonnell, E. H., Sedor, F. A., & Toffaletti, J. G. (2002). pH Effects on Measurements of Ionized Calcium and Ionized Magnesium in Blood. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2002-126-0947-peomoi
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.