Multi-Institutional Comparison of Whole Slide Digital Imaging and Optical Microscopy for Interpretation of Hematoxylin-Eosin–Stained Breast Tissue Sections
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Context. —Whole slide imaging (WSI) is now used for educational purposes, for consultation, and for archiving and quantitation of immunostains. However, it is not routinely used for the primary diagnosis of hematoxylin-eosin–stained tissue sections. Objective. —To compare WSI using the Aperio digital pathology system (Aperio Technologies, Inc, Vista, California) with optical microscopy (OM) for the interpretation of hematoxylin-eosin–stained tissue sections of breast lesions. Design. —The study was conducted at 3 clinical sites; 3 breast pathologists interpreted 150 hematoxylin-eosin–stained slides at each site, 3 times each by WSI and 3 times each by OM. For WSI, slides were scanned using an Aperio ScanScope and interpreted on a computer monitor using Aperio ImageScope software and Aperio Spectrum data management software. Pathologic interpretations were recorded using the College of American Pathologists breast checklist. WSI diagnoses were compared with OM diagnoses for accuracy, precision (interpathologist variation), and reproducibility (intrapathologist variation). Results were considered accurate only if the interpretation matched exactly between WSI and OM. The proportion of accurate results reported by each pathologist was expressed as a percentage for the comparison of the 2 platforms. Results. —The accuracy of WSI for classifying lesions as not carcinoma or as noninvasive (ductal or lobular) or invasive (ductal, lobular, or other) carcinoma was 90.5%. The accuracy of OM was 92.1%. The precision and reproducibility of WSI and OM were determined on the basis of pairwise comparisons (3 comparisons for each slide, resulting in 36 possible comparisons). The overall precision of WSI was 90.5% in comparison with 92.1% for OM; reproducibility of WSI was 91.6% in comparison with 94.5% for OM, respectively. Conclusions. —In this study, we demonstrated that WSI and OM have similar accuracy, precision, and reproducibility for interpreting hematoxylin-eosin–stained breast tissue sections. Further clinical studies using routine surgical pathology specimens would be useful to confirm these findings and facilitate the incorporation of WSI into diagnostic practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of telepathology, virtual microscopy, and whole slide imaging: Prospects for the future
Weinstein, R. S., Graham, A. R., Richter, L. C., Barker, G. P., Krupinski, E. A., Lopez, A. M., Erps, K. A., Bhattacharyya, A. K., Yagi, Y., & Gilbertson, J. R. (2009) · Human Pathology · doi:10.1016/j.humpath.2009.04.006 · Cited by 380
Cited by
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., et al. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000948 · Cited by 399
Validation of digital pathology imaging for primary histopathological diagnosis
Snead, D. R. J., Tsang, Y., Meskiri, A., Kimani, P. K., Crossman, R., Rajpoot, N. M., Blessing, E., Chen, K., Gopalakrishnan, K., Matthews, P., et al. (2016) · Histopathology · doi:10.1111/his.12879 · Cited by 238
Whole slide imaging equivalency and efficiency study: experience at a large academic center
Hanna, M. G., Reuter, V. E., Hameed, M. R., Tan, L. K., Chiang, S., Sigel, C., Hollmann, T., Giri, D., Samboy, J., Moradel, C., et al. (2019) · Modern Pathology · doi:10.1038/s41379-019-0205-0 · Cited by 215
Self-citationThe Diagnostic Concordance of Whole Slide Imaging and Light Microscopy: A Systematic Review
Goacher, E., Randell, R., Williams, B., & Treanor, D. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0025-ra · Cited by 173
The performance of digital microscopy for primary diagnosis in human pathology: a systematic review
Araújo, A. L. D., Arboleda, L. P. A., Palmier, N. R., Fonsêca, J. M., de Pauli Paglioni, M., Gomes-Silva, W., Ribeiro, A. C. P., Brandão, T. B., Simonato, L. E., Speight, P. M., et al. (2019) · Virchows Archiv · doi:10.1007/s00428-018-02519-z · Cited by 64
Metadata
- Authors
- Krishnamurthy, S., Mathews, K., McClure, S., Murray, M., Gilcrease, M., Albarracin, C., Spinosa, J., Chang, B., Ho, J., Holt, J., Cohen, A., Giri, D., Garg, K., Bassett, R. L., & Liang, K.
- Venue
- Archives of Pathology and Laboratory Medicine
- Published
- 2013-12
- Volume
- 137
- Issue
- 12
- Pages
- 1733-1739
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2125942968
- Cited by
- 71
- References
- 1
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-Institutional Comparison of Whole Slide Digital Imaging and Optical Microscopy for Interpretation of Hematoxylin-Eosin–Stained Breast Tissue Sections. https://app.cochat.ai/papers/10.5858/arpa.2012-0437-oa
- The paper
- Krishnamurthy, S., Mathews, K., McClure, S., Murray, M., Gilcrease, M., Albarracin, C., Spinosa, J., Chang, B., Ho, J., Holt, J., Cohen, A., Giri, D., Garg, K., Bassett, R. L., & Liang, K. (2013). Multi-Institutional Comparison of Whole Slide Digital Imaging and Optical Microscopy for Interpretation of Hematoxylin-Eosin–Stained Breast Tissue Sections. Archives of Pathology and Laboratory Medicine. https://doi.org/10.5858/arpa.2012-0437-oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.