A Prospective, Multi-Institutional Diagnostic Trial to Determine Pathologist Accuracy in Estimation of Percentage of Malignant Cells
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Context. —The fraction of malignant cells in tumor tissue submitted for tests of genetic alterations is a critical variable in testing accuracy. That fraction is currently determined by pathologist visual estimation of the percentage of malignant cells. Inaccuracy could lead to a false-negative test result. Objective. —To describe a prospective, multi-institutional study to determine pathologist estimation accuracy. Design. —Ten ×20 magnification images of hematoxylin-eosin–stained colon tissue specimens were sent as an educational component of the College of American Pathologists KRAS-B 2011 Survey. Data from 194 labs were analyzed and compared to a criterion standard with comprehensive manual nuclear counts. Results. —Survey responses indicated low interlaboratory precision of pathologist estimation, but mean estimates were fairly accurate. A total of 5 of the 10 cases assessed showed more than 10% of respondents overestimating in a manner that could lead to false-negative test results. Conclusions. —The significance of estimation errors resulting in molecular testing failures with implications for patient care is unknown, but the current study suggests false-negative test results may occur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allegra, C. J., Jessup, J. M., Somerfield, M. R., Hamilton, S. R., Hammond, E. H., Hayes, D. F., McAllister, P. K., Morton, R. F., & Schilsky, R. L. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.21.9170 · Cited by 1,156
Cited by
Sholl, L. M., Aisner, D. L., Varella-Garcia, M., Berry, L. D., Dias-Santagata, D., Wistuba, I. I., Chen, H., Fujimoto, J., Kugler, K., Franklin, W. A., et al. (2015) · Journal of Thoracic Oncology · doi:10.1097/jto.0000000000000516 · Cited by 430
Best practices for variant calling in clinical sequencing
Koboldt, D. C. (2020) · Genome Medicine · doi:10.1186/s13073-020-00791-w · Cited by 384
Sepulveda, A. R., Hamilton, S. R., Allegra, C. J., Grody, W., Cushman-Vokoun, A. M., Funkhouser, W. K., Kopetz, S. E., Lieu, C., Lindor, N. M., Minsky, B. D., et al. (2017) · Journal of Clinical Oncology · doi:10.1200/jco.2016.71.9807 · Cited by 360
Translational AI and deep learning in diagnostic pathology
Serag, A., Ion-Margineanu, A., Qureshi, H., McMillan, R., Saint Martin, M.-J., Diamond, J., O'Reilly, P., & Hamilton, P. (2019) · Frontiers in Medicine · doi:10.3389/fmed.2019.00185 · Cited by 274
Noorbakhsh, J., Farahmand, S., Foroughi pour, A., Namburi, S., Caruana, D., Rimm, D., Soltanieh-ha, M., Zarringhalam, K., & Chuang, J. H. (2020) · Nature Communications · doi:10.1038/s41467-020-20030-5 · Cited by 206
Self-citation
Metadata
- Authors
- Viray, H., Li, K., Long, T. A., Vasalos, P., Bridge, J. A., Jennings, L. J., Halling, K. C., Hameed, M., & Rimm, D. L.
- Venue
- Archives of Pathology and Laboratory Medicine
- Published
- 2013-11
- Volume
- 137
- Issue
- 11
- Pages
- 1545-1549
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2015823489
- Cited by
- 106
- References
- 1
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Prospective, Multi-Institutional Diagnostic Trial to Determine Pathologist Accuracy in Estimation of Percentage of Malignant Cells. https://app.cochat.ai/papers/10.5858/arpa.2012-0561-cp
- The paper
- Viray, H., Li, K., Long, T. A., Vasalos, P., Bridge, J. A., Jennings, L. J., Halling, K. C., Hameed, M., & Rimm, D. L. (2013). A Prospective, Multi-Institutional Diagnostic Trial to Determine Pathologist Accuracy in Estimation of Percentage of Malignant Cells. Archives of Pathology and Laboratory Medicine. https://doi.org/10.5858/arpa.2012-0561-cp
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.