The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
State-of-the-art review of CO2 demand controlled ventilation technology and application
Open accessAbstract
The control of outdoor air intake rates in mechanically ventilated buildings based on indoor carbon dioxide (CO 2 ) levels, often referred to as CO 2 demand controlled ventilation (DCV), has the potential for reducing the energy consumption associated with building ventilation in some commercial and institutional buildings.Carbon dioxide DCV has been discussed, promoted, studied and demonstrated for about twenty years, but questions still remain regarding the actual energy savings potential as a function of climate, ventilation system features, and building occupancy.In addition, questions exist as to the indoor air quality (IAQ) impacts of the approach and the best way to implement CO 2 DCV in general and in a given building.This report presents a state-of-the-art review of CO 2 DCV technology and application including discussion of the concept and its application, and a literature review.In addition the regulatory and standard requirements impacting CO 2 DCV are also examined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 2×
“In another field test, Sodergren (1982) presented graphs of the CO2 concentration at multiple locations in an office but did not make specific recommendations on sensor location.”
Cited by
Dounis, A. I., & Caraiscos, C. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.015 · Cited by 851
Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Dias Carrilho, J., & Gameiro da Silva, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 515
Azuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360
A review of smart building sensing system for better indoor environment control
Dong, B., Prakash, V., Feng, F., & O'Neill, Z. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.025 · Cited by 360
Metadata
- Authors
- Emmerich, S. J., & Persily, A. K.
- Published
- 2001
- OpenAlex
- W2740637235
- Cited by
- 208
- References
- 1
- Type
- report
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State-of-the-art review of CO2 demand controlled ventilation technology and application. https://app.cochat.ai/papers/10.6028/nist.ir.6729
- The paper
- Emmerich, S. J., & Persily, A. K. (2001). State-of-the-art review of CO2 demand controlled ventilation technology and application. https://doi.org/10.6028/nist.ir.6729
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.