Reactive Power Management with Distributed Energy Resources
Open accessAbstract
As grids lean more on renewables, managing reactive power is crucial for stability and reliability. The IEA PVPS Task 14 report explores reactive power management’s vital role in grid stabilization, voltage control, and maintaining power quality, emphasizing the importance of Distributed Energy Resources (DERs) in reactive power control. It includes case studies and insights from various countries on utilizing photovoltaics and renewables for reactive power management.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In Germany, Austria, Italy, and Japan, distributed energy resource facilities connected to distribution networks must have the ability to control reactive power.
“Thus, according to report [45], in Germany, Austria, Italy, and Japan, distributed energy resource facilities connected to distribution networks must have the ability to control reactive power.”
From Determining Volt/Var Characteristics of Electric Vehicle Charging Station Inverters for Voltage Regulation in Distribution Networks (2024) · cites this paper as [45]
Section 2.1.1 says German grid codes require connected DER to provide controllable reactive power; sections 2.3 and 2.5.2 describe Japanese power-factor control and Italian reactive-power requirements, including for generators connected through distribution grids. Sections 4.2.1 and 2.4.1 describe Austrian requirements, but explicitly identify required reactive-power functionality for power-electronic grid interfaces rather than every DER facility. The claim's unqualified 'facilities ... must' is therefore broader than the requirements stated in our copy. (LLM, conf=0.82)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 10
- Jeff D. Makholm, "The New "Three Ds" in Regulation-Decarbonization, Decentralization, and Digitization," Natural Gas & Electricity, vol. 35, no. 2, pp. 18-22, 2018, doi: 10.1002/gas.22075. · DOI
- N. Mahdavi Tabatabaei, A. Jafari Aghbolaghi, N. Bizon, and F. Blaabjerg, Reactive power control in AC power systems: Fundamentals and current issues. Cham: Springer, 2017.
- C. Kumar, M. Lakshmanan, S. Jaisiva, K. Prabaakaran, S. Barua, and H. H. Fayek, "Reactive power control in renewable rich power grids: A literature review," IET Renewable Power Generation, vol. 17, no. 5, pp. 1303-1327, 2023, doi: 10.1049/rpg2.12674. · DOI
- D. Stanelyte and V. Radziukynas, "Review of Voltage and Reactive Power Control Algorithms in Electrical Distribution Networks," Energies, vol. 13, no. 1, p. 58, 2020, doi: 10.3390/en13010058. · DOI
- M. Kraiczy, Reactive power grid adequacy studies for distribution grids with high distributed generation. Kassel: kassel university press c/o Universität Kassel -Universitätsbibliothek, 2021.
- M. Kreutziger, W. Becker, P. Schegner, and E. Habermann, "Anwendungsfalloptimierte Bereitstellung von Blindleistung aus dezentralen Erzeugungsanlagen im 110-kV-Verteilnetz," in 14. Symposium Energieinnovation 2016. Accessed: 30.02.2024. [Online]. Available: https://www.tugraz.at/fileadmin/user_ upload/Events/Eninnov2016/files/lf/Session_C4/LF_Kreutziger.pdf
- M. Kraiczy et al., "Benefits of advanced PV power forecasts for congestion management and reactive power management at the distribution level," ETG-Kongress 2021, pp. 77-82, 2021. [Online]. Available: https:// ieeexplore.ieee.org/abstract/document/9469522
- P. Zehetbauer, C. Korner, T. Wieland, S. Brandl, and M. Ortner, "Data driven photovoltaic regionalization approach for distribution system operator supply areas," 27th International Conference on Electricity Distribution, 2023, doi: 10.1049/icp.2023.0979. · DOI
- B. Herndler, R. Schwalbe, C. Korner, T. Wieland, S. Brandl, and M. Ortner, "Regionalised approach to heat pump allocation and its impact on LV network reinforcement re-quirements," 27th International Conference on Electricity Distribution, 2023. [Online]. Available: https://ieeexplore.ieee.org/document/10267207
- B. Herndler et al., "Impact of EV regionalization on network reinforcement requirements," 27th International Conference on Electricity Distribution, 2023. [Online]. Available: https://ieeexplore.ieee.org/document/ 10267371
Cited by
Sorted by citations
Voronin, V., Nepsha, F., & Ilyushin, P. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15120553 · Cited by 3 · see citing works
- Authors
- Altayara, A., Mende, D., Bucher, C., Ogasawara, Y., Omine, E., Ueda, Y., Bründliger, R., Adinolfi, G., Graditi, G., Stock, D. S., Wang, H., Omine, E., & Heilscher, G.
- Published
- 2024
- OpenAlex
- W4402102488
- Cited by
- 5
- References
- 0
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2
- Type
- report
- Language
- en
- Open access
- gold
- dx.doi.org
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Keywords
- reactive power management, distributed energy resources, voltage regulation, power quality, grid stability, photovoltaics, renewable energy integration, reactive power control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review