CoChat

Estimating the Lactate Threshold Using Wireless Near-Infrared Spectroscopy and Threshold Detection Analyses

Open access
Trent E. Cayot, Shara G Robinson, Lindsay E Davis, Paul A. Bender, John R. Thistlethwaite, Craig E. Broeder, Jakob D. Lauver · 2021 · International Journal of Exercise Science

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

International Journal of Exercise Science 14(4): 284-294, 2021. The present investigation examined the ability of two threshold detection analyses (maximum distance, Dmax; modified maximum distance, mDmax) in identifying the near-infrared spectroscopy (NIRS) threshold, a lactate threshold (LT) estimate, from exercising tissue oxygen saturation (StO2) responses. Additionally, the test-retest reliability of exercising StO2 and total hemoglobin concentration (THC) responses were examined at moderate and peak cycling intensities. Fourteen healthy, recreationally active participants performed maximal incremental step cycling tests (+25 W / 3 minutes) to volitional fatigue on two separate occasions while StO2 and THC of the vastus lateralis were monitored. Exercising blood [lactate] was collected during Session One. LT and NIRS thresholds (NIRS1, NIRS2) were then determined using Dmax and mDmax threshold analyses. Significant (p < 0.05), moderate correlations were detected between LT and NIRS1 when using Dmax (LT = 130 ± 49 W, NIRS1 = 136 ± 34 W, r = 0.690), but not for mDmax (r = 0.487). No significant test-retest reliability for the NIRS thresholds were observed for Dmax (ICC = 0.351) or mDmax (ICC = 0.385). Exercising StO2 responses demonstrated good reliability (ICC = 0.841-0.873) while exercising THC responses demonstrated moderate-good reliability (ICC = 0.720-0.873) at moderate and peak exercise intensities. The results of this study suggest that neither the Dmax nor mDmax threshold analyses should be used to estimate the LT due to the unreliable detection of the NIRS threshold from session to session.

Overview

Integrity signals

Registry

Crossref · 10.70252/hbra1900

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 27 references

Cited by

Metadata

Authors
Cayot, T. E., Robinson, S. G., Davis, L. E., Bender, P. A., Thistlethwaite, J. R., Broeder, C. E., & Lauver, J. D.
Affiliations
  • University of Indianapolis (US)
  • Ohio Dominican University (US)
  • Wittenberg University (US)
  • Inštitut za Nutricionistiko (SI)
  • Coastal Carolina University (US)
Venue
International Journal of Exercise Science
Published
2021
Volume
14
Issue
4
Pages
284-294
ISSN
1939-795X (ISSN-L)
OpenAlex
W3150305159
Cited by
19
References
27
Citations by year
2026: 3 · 2025: 6 · 2024: 5 · 2023: 2 · 2022: 3
FWCI
1.48
Type
journal article
Language
en
Open access
Licence
cc-by-nd
Locations
  • International journal of exercise science (publishedVersion, cc-by-nd)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion)
  • TopSCHOLAR (Western Kentucky University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
lactate threshold, near-infrared spectroscopy, tissue oxygen saturation, maximum distance, test-retest reliability, total hemoglobin, vastus lateralis, incremental cycling test, exercise intensity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A second model labelled each claim on 2026-10-13 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.