Estimating the Lactate Threshold Using Wireless Near-Infrared Spectroscopy and Threshold Detection Analyses
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
International Journal of Exercise Science 14(4): 284-294, 2021. The present investigation examined the ability of two threshold detection analyses (maximum distance, Dmax; modified maximum distance, mDmax) in identifying the near-infrared spectroscopy (NIRS) threshold, a lactate threshold (LT) estimate, from exercising tissue oxygen saturation (StO2) responses. Additionally, the test-retest reliability of exercising StO2 and total hemoglobin concentration (THC) responses were examined at moderate and peak cycling intensities. Fourteen healthy, recreationally active participants performed maximal incremental step cycling tests (+25 W / 3 minutes) to volitional fatigue on two separate occasions while StO2 and THC of the vastus lateralis were monitored. Exercising blood [lactate] was collected during Session One. LT and NIRS thresholds (NIRS1, NIRS2) were then determined using Dmax and mDmax threshold analyses. Significant (p < 0.05), moderate correlations were detected between LT and NIRS1 when using Dmax (LT = 130 ± 49 W, NIRS1 = 136 ± 34 W, r = 0.690), but not for mDmax (r = 0.487). No significant test-retest reliability for the NIRS thresholds were observed for Dmax (ICC = 0.351) or mDmax (ICC = 0.385). Exercising StO2 responses demonstrated good reliability (ICC = 0.841-0.873) while exercising THC responses demonstrated moderate-good reliability (ICC = 0.720-0.873) at moderate and peak exercise intensities. The results of this study suggest that neither the Dmax nor mDmax threshold analyses should be used to estimate the LT due to the unreliable detection of the NIRS threshold from session to session.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Ekkekakis, P., Parfitt, G., & Petruzzello, S. J. (2011) · Sports Medicine · doi:10.2165/11590680-000000000-00000 · Cited by 1,215 · cited 1×
“Additionally, exercise below the LT is associated with more favorable affective responses than exercise above the LT, which may impact exercise adherence (8).”
BackgroundEthical Issues Relating to Scientific Discovery in Exercise Science
Navalta, J. W., & Stone, W. J. (2019) · International Journal of Exercise Science · doi:10.70252/eycd6235 · Cited by 679 · cited 7×
“International Journal of Exercise Science http://www.intjexersci.com The reliability of the microvascular oxygenation measurements (StO2, [THC]) observed in the present and previous (6) investigations, along with the portability of the wireless NIRS device suggest that it may be useful for measuring changes in local m…”
MethodInfluentialSeiler, K. S., & Kjerland, G. Ø. (2006) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2004.00418.x · Cited by 643 · cited 1×
“The lactate threshold (LT) is an example of a physiological threshold that can be monitored throughout training and used to prescribe individualized exercise intensities, such as in threshold and polarized training programs (28, 29).”
BackgroundFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Stöggl, T., & Sperlich, B. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00033 · Cited by 288 · cited 1×
“The lactate threshold (LT) is an example of a physiological threshold that can be monitored throughout training and used to prescribe individualized exercise intensities, such as in threshold and polarized training programs (28, 29).”
BackgroundTønnessen, E., Sylta, Ø., Haugen, T. A., Hem, E., Svendsen, I. S., & Seiler, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0101796 · Cited by 255
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248 · cited 17×
“Participants then completed a standardized 25-watt (W) warm-up for five minutes followed by the GXT (+25 W every 3 minutes) to volitional fatigue.”
BackgroundMethodInfluentialValidity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206 · cited 8×
“This secondary objective will expand upon previous findings and help practitioners determine if NIRS techniques could be used as a reliable internal training load metric during exercise in less trained (recreationally active) populations (3, 6).”
BackgroundInfluentialBlood lactate parameters related to aerobic capacity and endurance performance
Yoshida, T., Chida, M., Ichioka, M., & Suda, Y. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00696368 · Cited by 183 · cited 1×
“The LT has also been associated with peak oxygen uptake (VO2PEAK), endurance exercise performance, and training status, making it an important physiological metric for practitioners to monitor throughout a training program (1, 14, 19, 21, 33).”
BackgroundDavis, S. L., Fadel, P. J., Cui, J., Thomas, G. D., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2005 · Cited by 179
Lactate kinetics at the lactate threshold in trained and untrained men
Messonnier, L. A., Emhoff, C.-A. W., Fattor, J. A., Horning, M. A., Carlson, T. J., & Brooks, G. A. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00043.2013 · Cited by 169 · cited 2×
“The LT has also been associated with peak oxygen uptake (VO2PEAK), endurance exercise performance, and training status, making it an important physiological metric for practitioners to monitor throughout a training program (1, 14, 19, 21, 33).”
BackgroundPredictive validity of ventilatory and lactate thresholds for cycling time trial performance
Amann, M., Subudhi, A. W., & Foster, C. (2006) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2004.00424.x · Cited by 112 · cited 1×
“The LT has also been associated with peak oxygen uptake (VO2PEAK), endurance exercise performance, and training status, making it an important physiological metric for practitioners to monitor throughout a training program (1, 14, 19, 21, 33).”
BackgroundFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107 · cited 3×
“However, previous investigations that have demonstrated valid NIRS threshold measurements, have done so in trained populations using proprietary algorithms that identify the NIRS threshold from the exercising StO2 data (2, 9).”
BackgroundMethodA ‘New’ Method to Normalise Exercise Intensity
Lansley, K. E., DiMenna, F. J., Bailey, S. J., & Jones, A. M. (2011) · International Journal of Sports Medicine · doi:10.1055/s-0031-1273754 · Cited by 107
Craig, J. C., Broxterman, R. M., Wilcox, S. L., Chen, C., & Barstow, T. J. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2017 · Cited by 95 · cited 1×
“This should be considered when using NIRS in diverse populations as higher adipose tissue thicknesses could attenuate the scattering of the NIRS signal, thus potentially affecting the StO2 measurements (5).”
BackgroundLarsson, P., Olofsson, P., Jakobsson, E., Burlin, L., & Henriksson-Larsén, K. (2002) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1034/j.1600-0838.2002.01161.x · Cited by 70 · cited 1×
“The LT has also been associated with peak oxygen uptake (VO2PEAK), endurance exercise performance, and training status, making it an important physiological metric for practitioners to monitor throughout a training program (1, 14, 19, 21, 33).”
BackgroundAsymmetry of quadriceps muscle oxygenation during elite short-track speed skating
HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f8942 · Cited by 63 · cited 1×
“This is also important to consider as the exercising microvascular oxygenation response may vary at different locations within the same muscle and/or within the contralateral muscle (16, 22).”
BackgroundWearable Lactate Threshold Predicting Device is Valid and Reliable in Runners
Borges, N. R., & Driller, M. W. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001307 · Cited by 59 · cited 4×
“However, previous investigations that have demonstrated valid NIRS threshold measurements, have done so in trained populations using proprietary algorithms that identify the NIRS threshold from the exercising StO2 data (2, 9).”
BackgroundMethodInfluentialBorn, D.-P., Stöggl, T., Swarén, M., & Björklund, G. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0101 · Cited by 59 · cited 2×
“Lastly, StO2 has been shown to be more valid at monitoring exercise intensity during running compared to heart rate (3).”
BackgroundOkushima, D., Poole, D. C., Barstow, T. J., Rossiter, H. B., Kondo, N., Bowen, T. S., Amano, T., & Koga, S. (2016) · Physiological Reports · doi:10.14814/phy2.13065 · Cited by 58 · cited 3×
“These findings are consistent with the notion that the capacity for oxygen extraction between the capillaries and skeletal muscle relates to the aerobic capacity of active muscle, which may affect the validity of identifying the NIRS threshold when estimating the LT in less aerobically trained populations (24).”
BackgroundSalvadego, D., Keramidas, M. E., Brocca, L., Domenis, R., Mavelli, I., Rittweger, J., Eiken, O., Mekjavic, I. B., & Grassi, B. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00832.2015 · Cited by 37 · cited 1×
“Previous research has demonstrated that trained individuals with greater aerobic capacity (higher VO2PEAK) have a larger deoxygenation ability (decrease in StO2) during maximal exercise than those with lower aerobic capacity (24, 27).”
BackgroundMiyamoto, N., Wakahara, T., Ema, R., & Kawakami, Y. (2013) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12054 · Cited by 35 · cited 1×
“This is also important to consider as the exercising microvascular oxygenation response may vary at different locations within the same muscle and/or within the contralateral muscle (16, 22).”
BackgroundCerda‐Kohler, H., Burgos, C., Ramírez‐Campillo, R., Valdés-Cerda, M., Martín, E. B.-S., Zapata-Gómez, D., Andrade, D. C., & Izquierdo, M. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001368 · Cited by 33 · cited 15×
“Participants then completed a standardized 25-watt (W) warm-up for five minutes followed by the GXT (+25 W every 3 minutes) to volitional fatigue.”
BackgroundMethodInfluentialReproducibility of muscle oxygen saturation
Thiel, C., Vogt, L., Himmelreich, H., Hübscher, M., & Banzer, W. (2011) · International Journal of Sports Medicine · doi:10.1055/s-0030-1269922 · Cited by 27 · cited 1×
“However, the StO2 reliability has been shown to decrease when absolute work rates increase above 250 W in well-trained cyclists, potentially due to more intense muscular contractions impairing muscle perfusion (6, 30).”
BackgroundRaleigh, C. J., Donne, B., & Fleming, N. (2018) · International Journal of Exercise Science · doi:10.70252/buct5185 · Cited by 19 · cited 2×
“However, it is important to investigate the validity and reliability of the NIRS threshold detection method as multiple analysis methods have been proposed (proprietary algorithms, visual inspection, segmented regression analysis) and to determine if the NIRS threshold assessments could be used in populations outside…”
MethodA Validation Study of a Noninvasive Lactate Threshold Device
McMorries, R. M., Joubert, D. P., Jones, E. J., & Faries, M. D. (2019) · International Journal of Exercise Science · doi:10.70252/loed6863 · Cited by 14 · cited 2×
“However, it is important to investigate the validity and reliability of the NIRS threshold detection method as multiple analysis methods have been proposed (proprietary algorithms, visual inspection, segmented regression analysis) and to determine if the NIRS threshold assessments could be used in populations outside…”
Method
Cited by
Muscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
Sendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
“The second threshold was determined using the blood lactate concentration and muscle oxygenation in different sports such as cycling 16,17,46–48 , running 44,45,49 and rowing 26 .”
BackgroundMethodInfluentialvan Hooff, M., Meijer, E. J., Scheltinga, M. R. M., Savelberg, H. H. C. M., & Schep, G. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12738 · Cited by 20
Stuer, L., Teso, M., Colosio, A. L., Loi, M., Mucci, P., Pogliaghi, S., Boone, J., & Caen, K. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05654-5 · Cited by 13
“Their study found a very good reliability and thus supported previous investigations on reliability of NIRS kinetics using CW NIRS (Lucero et al. 2018; Fennell et al. 2023; Cayot et al. 2021; McLay et al. 2016).”
Sendra-Pérez, C., Encarnación-Martínez, A., Oficial-Casado, F., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1457 · Cited by 9
Metadata
- Authors
- Cayot, T. E., Robinson, S. G., Davis, L. E., Bender, P. A., Thistlethwaite, J. R., Broeder, C. E., & Lauver, J. D.
- Affiliations
- University of Indianapolis (US)
- Ohio Dominican University (US)
- Wittenberg University (US)
- Inštitut za Nutricionistiko (SI)
- Coastal Carolina University (US)
- Venue
- International Journal of Exercise Science
- Published
- 2021
- Volume
- 14
- Issue
- 4
- Pages
- 284-294
- ISSN
- 1939-795X (ISSN-L)
- PMC
- PMC8136573
- OpenAlex
- W3150305159
- Semantic Scholar
- c4cd27bbe46dbbddc0fbc17d9047cdacfab3574a
- Cited by
- 19
- References
- 27
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 2 · 2022: 3
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nd
- Locations
- International journal of exercise science (publishedVersion, cc-by-nd)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion)
- TopSCHOLAR (Western Kentucky University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- lactate threshold, near-infrared spectroscopy, tissue oxygen saturation, maximum distance, test-retest reliability, total hemoglobin, vastus lateralis, incremental cycling test, exercise intensity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A second model labelled each claim on 2026-10-13 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.