CoChat

Measuring Activity Energy Expenditure: Accuracy of the GT3X+ and Actiheart Monitors

Open access
McMinn, David, Acharya, Rijan, Rowe, David A., Gray, Stuart R., Allan, Julia L. · 2013 · International Journal of Exercise Science
Cited by 48

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The purpose was to determine the accuracy of the GT3X+ and Actiheart monitors for estimating energy expenditure (EE) and steps. Additionally, to investigate agreement between waist- and wrist-mounted GT3X+ EE outputs. Nineteen participants (mean age=30) completed three treadmill walking trials at self-selected slow, medium, and fast speeds while wearing two GT3X+ (waist and wrist) and an Actiheart. Activity monitor EE was compared to indirect calorimetry criterion EE using Pearson correlations and ANOVAs. A Bland-Altman plot was used to investigate agreement between GT3X+ waist- and wrist-determined EE. GT3X+ determined steps were compared to researcher-counted steps using ANOVAs. EE estimates from all monitors correlated highly with the criterion (r ranged from .72 to .82). However, the GT3X+ (waist and wrist) underestimated EE during slow walking and overestimated EE during fast walking. There were no differences among GT3X+ (waist and wrist) estimates of EE and the criterion during the medium trial. Actiheart estimated EE was not significantly different from measured EE during all trials. The Bland-Altman plot indicated that at EE rates above 4 kcal·min-1, the GT3X+ worn on the wrist underestimated EE compared to when it was worn on the waist. There were no differences between GT3X+ waist-determined steps and researcher-counted steps for all trials. GT3X+ EE correlates highly with measured EE, but has poor absolute agreement during slow and fast walking. GT3X+ step estimates are accurate across the continuum of walking speeds when waist (but not wrist) mounted. Wrist-mounted device outputs are not comparable to waist-mounted outputs. The Actiheart accurately estimates EE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.70252/qebt3375

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 48

Metadata

Authors
McMinn, D., Acharya, R., Rowe, D. A., Gray, S. R., & Allan, J. L.
Venue
International Journal of Exercise Science
Published
2013
Volume
6
Issue
3
Pages
217-229
ISSN
1939-795X (ISSN-L)
OpenAlex
W206009625
Cited by
48
References
6
FWCI
2.24
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measuring Activity Energy Expenditure: Accuracy of the GT3X+ and Actiheart Monitors. https://app.cochat.ai/papers/10.70252/qebt3375
The paper
McMinn, D., Acharya, R., Rowe, D. A., Gray, S. R., & Allan, J. L. (2013). Measuring Activity Energy Expenditure: Accuracy of the GT3X+ and Actiheart Monitors. International Journal of Exercise Science. https://doi.org/10.70252/qebt3375

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.