Exosomal ephrinA2 derived from serum as a potential biomarker for prostate cancer
Open accessThe DOI matches its Crossref record.
Abstract
Up-regulation of serum ephrinA2 is common in various malignancies and has been suggested as a potential biomarker for the diagnosis and prognosis of prostate cancer (PCa). However, the type of serum ephrinA2 expressed in PCa patients remains elusive. Furthermore, the level of exosomal ephrinA2 derived from serum is increased in patients with osteoporosis, a common complication of PCa patients undergoing androgen deprivation therapy. It is unknown whether exosomes derived from PCa patient serum contains ephrinA2. In this study, we explored the ephrinA2 expression in whole serum and tissues and identified the circulating exosomal ephrinA2 as a potential biomarker for PCa. Exosomes were isolated from patient sera by differential centrifugation and the presence of ephrinA2 was confirmed via electron microscopy and western blotting. The type of ephrinA2 in serum was evaluated by western blotting. The expression of serum ephrinA2 including secreted and cleaved ephrinA2 and exosomal ephrinA2 were detected by ELISA and western blotting. Compared with benign prostatic hyperplasia (BPH) and controls, the levels of whole serum ephrinA2 and exosomal ephrinA2 were significantly higher in PCa patients. Moreover, exosomal ephrinA2 expression was positively correlated with TNM staging and Gleason score of PCa patients. The diagnostic efficiency of exosomal ephrinA2 was superior to that of whole serum ephrinA2 and serum PSA in distinguishing PCa patients from those from BPH patents. Our study indicates that exosomal ephrinA2 has high potential as a biomarker for the presence of PCa and offers a new therapeutic target for this disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exosomes as a new frontier of cancer liquid biopsy
Yu, D., Li, Y., Wang, M., Gu, J., Xu, W., Cai, H., Fang, X., & Zhang, X. (2022) · Molecular Cancer · doi:10.1186/s12943-022-01509-9 · Cited by 855
Isolation and characterization of exosomes for cancer research
Zhu, L., Sun, H.-T., Wang, S., Huang, S.-L., Zheng, Y., Wang, C.-Q., Hu, B.-Y., Qin, W., Zou, T.-T., Fu, Y., et al. (2020) · Journal of Hematology & Oncology · doi:10.1186/s13045-020-00987-y · Cited by 520
Ramirez-Garrastacho, M., Bajo-Santos, C., Line, A., Martens-Uzunova, E. S., de la Fuente, J. M., Moros, M., Soekmadji, C., Tasken, K. A., & Llorente, A. (2022) · British Journal of Cancer · doi:10.1038/s41416-021-01610-8 · Cited by 130
“The EV levels of PTEN [194], flotillin 2 and PARK7 [195], ephrinA2 [196], Del-1 [197], the integrins ITGA3 and ITGB1 [198] and GGT1 activity [199] have also been reported to differentiate between PCa patients and healthy individuals and/or BPH patients.”
BackgroundEmpowering Exosomes with Aptamers for Precision Theranostics
Zheng, L., Li, J., Li, Y., Sun, W., Ma, L., Qu, F., & Tan, W. (2025) · Small Methods · doi:10.1002/smtd.202400551 · Cited by 21
Metadata
- Authors
- Li, S., Zhao, Y., Chen, W., Yin, L., Zhu, J., Zhang, H., Cai, C., Li, P., Huang, L., & Ma, P.
- Venue
- Journal of Cancer
- Publisher
- Ivyspring International Publisher
- Published
- 2018
- Volume
- 9
- Issue
- 15
- Pages
- 2659-2665
- ISSN
- 1837-9664 (ISSN-L)
- OpenAlex
- W2840645272
- Cited by
- 61
- References
- 0
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.