The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prediction of Tumor Recurrence and Therapy Monitoring Using Ultrasound-Guided Photoacoustic Imaging
Open accessAbstract
Selection and design of individualized treatments remains a key goal in cancer therapeutics; prediction of response and tumor recurrence following a given therapy provides a basis for subsequent personalized treatment design. We demonstrate an approach towards this goal with the example of photodynamic therapy (PDT) as the treatment modality and photoacoustic imaging (PAI) as a non-invasive, response and disease recurrence monitor in a murine model of glioblastoma (GBM). PDT is a photochemistry-based, clinically-used technique that consumes oxygen to generate cytotoxic species, thus causing changes in blood oxygen saturation (StO2). We hypothesize that this change in StO2 can be a surrogate marker for predicting treatment efficacy and tumor recurrence. PAI is a technique that can provide a 3D atlas of tumor StO2 by measuring oxygenated and deoxygenated hemoglobin. We demonstrate that tumors responding to PDT undergo approximately 85% change in StO2 by 24-hrs post-therapy while there is no significant change in StO2 values in the non-responding group. Furthermore, the 3D tumor StO2 maps predicted whether a tumor was likely to regrow at a later time point post-therapy. Information on the likelihood of tumor regrowth that normally would have been available only upon actual regrowth (10-30 days post treatment) in a xenograft tumor model, was available within 24-hrs of treatment using PAI, thus making early intervention a possibility. Given the advances and push towards availability of PAI in the clinical settings, the results of this study encourage applicability of PAI as an important step to guide and monitor therapies (e.g. PDT, radiation, anti-angiogenic) involving a change in StO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Cited by
Light Sources and Dosimetry Techniques for Photodynamic Therapy
Kim, M. M., & Darafsheh, A. (2020) · Photochemistry and Photobiology · doi:10.1111/php.13219 · Cited by 454
Mallidi, S., Anbil, S., Bulin, A.-L., Obaid, G., Ichikawa, M., & Hasan, T. (2016) · Theranostics · doi:10.7150/thno.16183 · Cited by 449
Self-citationChen, S., Zhong, Y., Fan, W., Xiang, J., Wang, G., Zhou, Q., Wang, J., Geng, Y., Sun, R., Zhang, Z., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00701-4 · Cited by 325
Recent Advances in Photoacoustic Imaging for Deep-Tissue Biomedical Applications
Wang, S., Lin, J., Wang, T., Chen, X., & Huang, P. (2016) · Theranostics · doi:10.7150/thno.16715 · Cited by 261
Menger, M. M., Körbel, C., Bauer, D., Bleimehl, M., Tobias, A. L., Braun, B. J., Herath, S. C., Rollmann, M. F., Laschke, M. W., Menger, M. D., et al. (2022) · Photoacoustics · doi:10.1016/j.pacs.2022.100409 · Cited by 35
Metadata
- Authors
- Mallidi, S., Watanabe, K., Timerman, D., Schoenfeld, D., & Hasan, T.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2015
- Volume
- 5
- Issue
- 3
- Pages
- 289-301
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2164176158
- Cited by
- 199
- References
- 1
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of Tumor Recurrence and Therapy Monitoring Using Ultrasound-Guided Photoacoustic Imaging. https://app.cochat.ai/papers/10.7150/thno.10155
- The paper
- Mallidi, S., Watanabe, K., Timerman, D., Schoenfeld, D., & Hasan, T. (2015). Prediction of Tumor Recurrence and Therapy Monitoring Using Ultrasound-Guided Photoacoustic Imaging. Theranostics. https://doi.org/10.7150/thno.10155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.