The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Optimization of the Ultrasound-Induced Blood-Brain Barrier Opening
Open accessAbstract
Current treatments of neurological and neurodegenerative diseases are limited due to the lack of a truly non-invasive, transient, and regionally selective brain drug delivery method. The brain is particularly difficult to deliver drugs to because of the blood-brain barrier (BBB). The impermeability of the BBB is due to the tight junctions connecting adjacent endothelial cells and highly regulatory transport systems of the endothelial cell membranes. The main function of the BBB is ion and volume regulation to ensure conditions necessary for proper synaptic and axonal signaling. However, the same permeability properties that keep the brain healthy also constitute the cause of the tremendous obstacles posed in its pharmacological treatment. The BBB prevents most neurologically active drugs from entering the brain and, as a result, has been isolated as the rate-limiting factor in brain drug delivery. Until a solution to the trans-BBB delivery problem is found, treatments of neurological diseases will remain impeded. Over the past decade, methods that combine Focused Ultrasound (FUS) and microbubbles have been shown to offer the unique capability of noninvasively, locally and transiently open the BBB so as to treat central nervous system (CNS) diseases. Four of the main challenges that have been taken on by our group and discussed in this paper are: 1) assess its safety profile, 2) unveil the mechanism by which the BBB opens and closes, 3) control and predict the opened BBB properties and duration of the opening and 4) assess its premise in brain drug delivery. All these challenges will be discussed, findings in both small (mice) and large (non-human primates) animals are shown and finally the clinical potential for this technique is shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Neurovascular regulation in the normal brain and in Alzheimer's disease
Iadecola, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1387 · Cited by 2,213
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Fung, L. K., Shin, M., Tyler, B., Brem, H., & Saltzman, W. M. (1996) · Pharmaceutical Research · doi:10.1023/a:1016083113123 · Cited by 213
Non-invasive opening of BBB by focused ultrasound
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2003) · Brain Edema XII · doi:10.1007/978-3-7091-0651-8_113 · Cited by 156 · cited 2×
“The advantage of having microbubbles present in the blood supply is that it allows for the reduction of the ultrasound intensity, avoidance of thermal effects, and the reduction of the likelihood of irreversible neuronal damage [11-21].”
BackgroundChoi, J. J., Pernot, M., Brown, T. R., Small, S. A., & Konofagou, E. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/004 · Cited by 141
Self-citation
Cited by
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
Disrupting the blood–brain barrier by focused ultrasound induces sterile inflammation
Kovacs, Z. I., Kim, S., Jikaria, N., Qureshi, F., Milo, B., Lewis, B. K., Bresler, M., Burks, S. R., & Frank, J. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1614777114 · Cited by 458
Sonodynamic therapy (SDT): a novel strategy for cancer nanotheranostics
Pan, X., Wang, H., Wang, S., Sun, X., Wang, L., Wang, W., Shen, H., & Liu, H. (2018) · Science China Life Sciences · doi:10.1007/s11427-017-9262-x · Cited by 302
Ultrasound treatment of neurological diseases — current and emerging applications
Leinenga, G., Langton, C., Nisbet, R., & Götz, J. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.13 · Cited by 275
Metadata
- Authors
- Konofagou, E. E.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2012
- Volume
- 2
- Issue
- 12
- Pages
- 1223-1237
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2109775563
- Cited by
- 173
- References
- 6
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.