Monitoring Error Rates In Illumina Sequencing
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Guaranteeing high-quality next-generation sequencing data in a rapidly changing environment is an ongoing challenge. The introduction of the Illumina NextSeq 500 and the depreciation of specific metrics from Illumina's Sequencing Analysis Viewer (SAV; Illumina, San Diego, CA, USA) have made it more difficult to determine directly the baseline error rate of sequencing runs. To improve our ability to measure base quality, we have created an open-source tool to construct the Percent Perfect Reads (PPR) plot, previously provided by the Illumina sequencers. The PPR program is compatible with HiSeq 2000/2500, MiSeq, and NextSeq 500 instruments and provides an alternative to Illumina's quality value (Q) scores for determining run quality. Whereas Q scores are representative of run quality, they are often overestimated and are sourced from different look-up tables for each platform. The PPR's unique capabilities as a cross-instrument comparison device, as a troubleshooting tool, and as a tool for monitoring instrument performance can provide an increase in clarity over SAV metrics that is often crucial for maintaining instrument health. These capabilities are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Substantial biases in ultra-short read data sets from high-throughput DNA sequencing
Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn425 · Cited by 1,088
Cited by
Single-Cell Map of Diverse Immune Phenotypes in the Breast Tumor Microenvironment
Azizi, E., Carr, A. J., Plitas, G., Cornish, A. E., Konopacki, C., Prabhakaran, S., Nainys, J., Wu, K., Kiseliovas, V., Setty, M., et al. (2018) · Cell · doi:10.1016/j.cell.2018.05.060 · Cited by 1,976
Early stage NSCLC — challenges to implementing ctDNA-based screening and MRD detection
Abbosh, C., Birkbak, N. J., & Swanton, C. (2018) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-018-0058-3 · Cited by 450
Diagnosis of invasive fungal infections: challenges and recent developments
Fang, W., Wu, J., Cheng, M., Zhu, X., Du, M., Chen, C., Liao, W., Zhi, K., & Pan, W. (2023) · Journal of Biomedical Science · doi:10.1186/s12929-023-00926-2 · Cited by 356
Woldemariam, N. T., Agafonov, O., Høyheim, B., Houston, R. D., Taggart, J. B., & Andreassen, R. (2019) · Cells · doi:10.3390/cells8010042 · Cited by 34
“The phiX Control is commonly used as an internal control to measure the proportion of ESVs when larger fragments are sequenced [31,32].”
BackgroundMethodMicrobiome depiction through user-adapted bioinformatic pipelines and parameters
Nayman, E. I., Schwartz, B. A., Polanco, F. C., Firek, A. K., Gumabong, A. C., Hofstee, N. J., Narasimhan, G., Cickovski, T., & Mathee, K. (2023) · Journal of Medical Microbiology · doi:10.1099/jmm.0.001756 · Cited by 6
Metadata
- Authors
- Manley, L. J., Ma, D., & Levine, S. S.
- Venue
- Journal of Biomolecular Techniques : JBT
- Published
- 2016-12
- Volume
- 27
- Issue
- 4
- Pages
- 125-128
- ISSN
- 1524-0215 (ISSN-L)
- 1943-4731
- OpenAlex
- W2523787414
- Cited by
- 71
- References
- 1
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Error Rates In Illumina Sequencing. https://app.cochat.ai/papers/10.7171/jbt.16-2704-002
- The paper
- Manley, L. J., Ma, D., & Levine, S. S. (2016). Monitoring Error Rates In Illumina Sequencing. Journal of Biomolecular Techniques : JBT. https://doi.org/10.7171/jbt.16-2704-002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.