Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Wide QRS Complex Tachycardia: Reappraisal of a Common Clinical Problem

Masood, Akhtar, Mohammad, Shenasa, Mohammad, Jazayeri, Caceres, Jose, Patrick J., Tchou · 1988 · Annals of Internal Medicine

Abstract

BACKGROUND AND PURPOSE: Despite available criteria, diagnosis of the mechanisms of wide complex tachycardia is often incorrect. We aimed in this study to identify reasons for misdiagnoses and the value and limitations of clinical and surface electrocardiographic criteria. DATA IDENTIFICATION: The analyzed data of 150 consecutive patients with wide QRS tachycardia from this study and a literature search of key papers in English since 1960 on clinical and surface electrocardiographic criteria form the basis of this report. The final correct diagnosis was made with intracardiac electrograms. DATA EXTRACTION AND ANALYSIS: Among the 150 patients, 122 had ventricular tachycardia, 21 had supraventricular tachycardia with aberrant conduction, and 7 had accessory pathway conduction. Only 39 of 122 patients with ventricular tachycardia were correctly diagnosed initially. In others, the diagnoses were supraventricular tachycardia with aberrant conduction (43 of 122) or simply a wide QRS tachycardia (40 of 122). Misdiagnosis in patients with aberrant or accessory pathway conduction was also common. Standard electrocardiographic criteria for ventricular tachycardia had unacceptable sensitivity, poor specificity, or both. Collectively such criteria allowed a correct diagnosis of ventricular tachycardia in 92% of cases. Diagnosis of ventricular tachycardia was also suggested by its association with structural heart disease. Criteria suggestive of ventricular tachycardia included atrioventricular dissociation, positive QRS concordance, axis less than -90 deg to +/- 180 deg, combination of left bundle branch block and right axis, QRS duration of greater than 140 ms with right bundle branch block and greater than 160 ms with left bundle branch block and, a different QRS during tachycardia compared to baseline preexisting bundle branch block. CONCLUSIONS: Ventricular tachycardia is the commonest underlying mechanism for wide QRS tachycardia. A correct diagnosis can usually be made from clinical and surface electrocardiographic criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-109-11-905

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Masood, A., Mohammad, S., Mohammad, J., Caceres, J., & Patrick J., T.
Venue
Annals of Internal Medicine
Published
1988-12-01
Volume
109
Issue
11
Pages
905-912
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2049966555
Cited by
210
References
1
FWCI
3.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wide QRS Complex Tachycardia: Reappraisal of a Common Clinical Problem. https://app.cochat.ai/papers/10.7326/0003-4819-109-11-905
The paper
Masood, A., Mohammad, S., Mohammad, J., Caceres, J., & Patrick J., T. (1988). Wide QRS Complex Tachycardia: Reappraisal of a Common Clinical Problem. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-109-11-905

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.