Cardiovascular and Renal Toxicity of a Nonionic Radiographic Contrast Agent after Cardiac Catheterization: A Prospective Trial
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVE: To determine the incidence of cardiovascular and renal toxicity of a nonionic contrast agent when used for cardiac catheterization, and to assess the value of electrolytes and urinalysis results as predictors of nephropathy induced by a contrast agent. STUDY DESIGN: Nonrandomized trial using a criterion standard and a cohort analytic study with a 48-hour follow-up. SETTING: Referral-based university hospital. PATIENTS: Convenience sample of patients having diagnostic cardiac catheterization. Renal function and clinical status were evaluated at baseline in 1,144 patients; at 24 hours in 1,077 (94%); and at 48 hours in 663 (57%). INTERVENTIONS: After patients received saline for hydration, coronary angiography and left ventriculography were done with iopamidol (average dose, 203 +/- 56 cc). MEASUREMENTS AND MAIN RESULTS: The definite and possible incidence of major acute cardiovascular complications from nonionic contrast media was 0.2% and 0.7%, respectively. The mean serum creatinine level increased 11.5 mumol/L from baseline at 24 hours (P less than 0.0001) and 16.8 mumol/L from baseline at 48 hours (P less than 0.0001). Results in a randomly selected training sample were studied to determine predictors of a rise in serum creatinine of 44.2 mumol/L or more. The baseline serum creatinine level and age were significant predictors of renal injury, but hypertension, diabetes mellitus, congestive heart failure, vascular disease, the volume of contrast agent injected or baseline values of urinary variables did not predict nephrotoxicity. In an independent validation sample, only the baseline serum creatinine level was confirmed as a predictor of nephrotoxicity, whereas age was not. A model that predicted contrast-induced nephropathy by the serum creatinine level showed an exponential increase in the risk for nephrotoxicity if the baseline level was 106.1 mumol/L or higher. CONCLUSIONS: Patients have a small but significant rise in serum creatinine after cardiac catheterization with a nonionic contrast agent. Baseline renal insufficiency is the only confirmed predictor of nonionic contrast-induced nephrotoxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Prediction Rules: Applications and Methodological Standards
Wasson, J. H., Sox, H. C., Neff, R. K., & Goldman, L. (1985) · New England Journal of Medicine · doi:10.1056/nejm198509263131306 · Cited by 1,357
Hospital-acquired renal insufficiency: A prospective study
Hou, S. H., Bushinsky, D. A., Wish, J. B., Cohen, J. J., & Harrington, J. T. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90618-6 · Cited by 1,238
The Complications of Coronary Arteriography
ADAMS, D. F., FRASER, D. B., & ABRAMS, H. L. (1973) · Circulation · doi:10.1161/01.cir.48.3.609 · Cited by 331
A New Information System for Medical Practice
Rosati, R. A. (1975) · Archives of Internal Medicine · doi:10.1001/archinte.135.8.1017 · Cited by 225
Coronary Angiography and Acute Renal Failure in Diabetic Azotemic Nephropathy
Weinrauch, L. A., HEALY, R. W., LELAND, O. S., GOLDSTEIN, H. H., KASSISSIEH, S. D., LIBERTINO, J. A., TAKACS, F. J., & D’Elia, J. A. (1977) · Annals of Internal Medicine · doi:10.7326/0003-4819-86-1-56 · Cited by 172
Cited by
A Comparison of Immediate Angioplasty with Thrombolytic Therapy for Acute Myocardial Infarction
Grines, C. L., Browne, K. F., Marco, J., Rothbaum, D., Stone, G. W., O'Keefe, J., Overlie, P., Donohue, B., Chelliah, N., Timmis, G. C., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281001 · Cited by 1,995
Acute Renal Failure After Coronary Intervention
McCullough, P. A., Wolyn, R., Rocher, L. L., Levin, R. N., & O’Neill, W. W. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)00150-2 · Cited by 1,671
Solomon, R., Werner, C., Mann, D., D'Elia, J., & Silva, P. (1994) · New England Journal of Medicine · doi:10.1056/nejm199411243312104 · Cited by 1,254
Contrast-Induced Acute Kidney Injury
McCullough, P. A., Choi, J. P., Feghali, G. A., Schussler, J. M., Stoler, R. M., Vallabahn, R. C., & Mehta, A. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.05.099 · Cited by 1,067
Nephrotoxicity of ionic and nonionic contrast media in 1196 patients: A randomized trial
Rudnick, M. R., Goldfarb, S., Wexler, L., Ludbrook, P. A., Murphy, M. J., Halpern, E. F., Hill, J. A., Winniford, M., Cohen, M. B., VanFossen, D. B., et al. (1995) · Kidney International · doi:10.1038/ki.1995.32 · Cited by 923
Metadata
- Authors
- Davidson, C. J., Hlatky, M., Morris, K. G., Pieper, K., Skelton, T. N., Schwab, S. J., & Bashore, T. M.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1989-01-15
- Volume
- 110
- Issue
- 2
- Pages
- 119-124
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2027695475
- Cited by
- 249
- References
- 5
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.